My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8417 EVERGREEN WAY 2022-05-23
>
Address Records
>
EVERGREEN WAY
>
8417
>
8417 EVERGREEN WAY 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:28:37 AM
Creation date
1/28/2021 9:01:05 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8417
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Mr. Mcllvain <br /> CRM Architects&Planners, Inc. <br /> Plan Check Number: B1805-010, Second Review <br /> December 4, 2018 <br /> Architectural <br /> General: <br /> 1. No additional comment. <br /> Fire Protection: <br /> 2. No additional comment. <br /> Egress: <br /> 3. This comment has not been complete addressed: <br /> a. No additional comment. <br /> b. No additional comment. <br /> c. The original comment state that the drawings shall specify the means of providing <br /> emergency power. The review comment was stated as Comment 8 on Sheet A2.1 <br /> instead of specifying a power source. The power source should be specified. See IBC <br /> Section 1008.3.4. <br /> Note 8 has been revised to specify power source <br /> 4. No additional comment. <br /> 5. No additional comment. <br /> 6. No additional comment. <br /> Accessibility: <br /> 7. No additional comment. <br /> Energy: <br /> 8. No additional comment. <br /> 9. No additional comment. <br /> 10.This comment has not been completely addressed. The original comment stated that the <br /> exterior foundation shall be insulated per WSEC-15 Section C402.2.6 and Table C402.1.3, <br /> and shall include a thermal break between the exterior foundation and the slab-on-grade. <br /> Sections A-A/A6.1 and B-B/A6.2 state to"provide insulation per IBC requirements" and <br /> reference the structural details. The revised foundation details on Sheet SF1.2 do not <br /> specify the insulation requirements and do not include a thermal break. The construction <br /> drawing shall be revised to specify the foundation insulation requirements. See IBC Section <br /> 107.2.1. <br /> Minimum R-10 perimeter foundation insulation noted on A-A/A6.1 and B-B A6.2. and added <br /> to structural details. <br /> 0 3200 Cedar Street © 425.257.8800 0 everettpw@everettwa.gov /f- <br /> Everett,WA 98201 425.257.8882 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.