( � <br /> Plan Check No. C 57702 <br /> Febniary 2, 1998 <br /> Page 2 of 6 <br /> �/6. At this time, the construction of the North wall for the ezisting suvcture is allowed to remain as <br /> built. If the current siding is removed in the future, however, 5/8 type X gypsum wall sheathing <br /> (or equiva(ent) will be required to be installed under the new siding material New windows wi11 <br /> similarly be required to be 3/4-hour rated as prescribed above. <br /> \ 7• A door appears ro be missing in the upper ioft space to gain access to the North room. <br /> Occupancy ��i���s�.,�" 3�= 02�, 3 GFw� �:��r3c ok <br /> -v 1� The toilet rooms shall have a mechanical ventilation system which will provide a complete air <br /> change every 15 minutes and be connected directly to the outside. The point of discharge shall <br /> be at least 3 feet from any opening which allows air entty into occupied portions of the building. <br /> Section 1202.2.1 <br /> In lieu of the above requirement, the toilet rooms may have either a fully openable window with <br /> ��� an area not less than 3 square feet, or a vertical duct not less than 100 square inches per Section <br /> 1202.2.1 <br /> It should be verified that the glazing adjacent to the tub is labeled safery glazing. Section 2406.4 <br /> '�4 <br /> COILS�I'UCf10tt <br /> ��i�. A moisture banier per Section 1402.1 (typically 15 Ib. feit) should be shown in the typical wall <br /> section. <br /> �. A complete typical roof and wall section should be provided tu include all coverings and <br /> materials proposed both inside and out. <br /> '�3/It should be specified that gypsum board backing used for tub or shower enclosures will be water <br /> resistant but will not be installed on the ceiling as the framing exceeds 12" o.c. Section 2512 <br /> / <br /> �4. A note should be added stating that a vapor barrier shall not be installed behind the water <br /> resistant gypsum wallboard (exterior walls). Section 2512 <br /> 5. The roof does not meet ventilation requirements prescribed in Section 1505. Calculations should <br /> be provided which show that a minimum of 567 square inches (net) uf openings are provided <br /> (based on 600 sq h at a 1:150 ratio). Note that soffit vents are not possible for much of the east <br /> roof as it joins the existing gable roof in a valley condition. <br /> 6. The soffit ventilation openings should be specified to be cortosion-resistant metal mesh having <br /> openings of 1/4 inch in dimension per Section 1505.3 Note chat this will rypically reduce the <br /> gross opening by 25%. <br />