Laserfiche WebLink
2001 -hin ton State Nonresidential Ener Code Com^��ance Form <br /> • • � <br /> 7001 Washrnglon S�ate Nmres�Een��al Eriargy CaCe CanF�iar�Fortna ��3��.�M � <br /> ProjectAddress ioszo 19t� Tvunua SE Date 7�Z3/2008 <br /> Complete the tollowing for all design A&B squirrel•cage,T•freme indudion pertnanently wired For Building Dapartment Use <br /> polyphase mators from 7 hp to 200 hp having synchronous speeds of 3600, 7P00 or 1200 rpm <br /> (unless one of the exceptions below applies). <br /> Motor Min.Nom. <br /> No.or Type Synch. Full load <br /> Localion HP (open/closed) Description of Appliwtion or Use Speed EKciency <br /> ANV-1 3 HP AIR HANDLER FAN MD1C)R 86.59 <br /> HP-1 1�3 HP HFJ�T PIR@ CONOENSEA FAN M1VR <BP.59 <br /> HP-2A 0.79 AMPS INDOOR VNIT FAN 11�TOR <B2.S9 <br /> HP-2B O.7S AMPS W'IUWR VNIT CONOENSER FAN lO1CIR GB2.SB <br /> AC-lA 0.76 AMPS INDOOR UNIT FAN PD1C1R GBZ.S9 <br /> 2C-2B 0.93 AMPS OUTDOOR VNIT CONDENSER FAN MJTOR <82.$Q <br /> Minimum Nominal Full-Load Efficienc <br /> Open Nbtas Closed Motas Exceptions: <br /> Synchrorous 1. Motors in systems designed to use more <br /> Speed(RPM) 3,600 1.800 1,200 3,fi00 1.800 1.200 than one speed oF a multi-speed motor. <br /> HP Elficien (%) EHicien (°/) 2. Motors already includetl in the eKciency <br /> 1.0 - 82.5 80.0 75.5 82.5 80.0 requirements for HVAC equipment(Tables 14-1 <br /> 1.5 82.5 84.0 84.0 82.5 D4.0 85.5 or <br /> 2.0 84.0 84.0 85.5 84.0 84.0 86.5 �4•Z)� <br /> 3.0 84.0 86.5 86.5 85.5 87.5 87.5 3. Motors that are an integral paA(i.e.not <br /> 5.0 85.5 87.5 87.5 87.5 8Z5 87.5 easily removed aid replaced of specialaed <br /> 7.5 87.5 88.5 88.5 88.5 89.5 89.5 process equipment(i.e.equipmenl which <br /> 10 885 89.5 902 89.5 89.5 89.5 requires a special motor,such as an explosion- <br /> 15 89.5 91.0 902 902 91.0 90.2 proof motor). <br /> 20 902 91.0 91.0 902 91.0 90.2 4_ Motors integral to a listed piece ot <br /> 25 91.0 917 917 91.0 92.4 917 equipment for which no qualirying motor has <br /> 30 91.0 924 92.4 91.0 924 g1.7 been approved(i.e.if the only U.L.listing for the <br /> 40 91.7 93.0 93.0 917 93.0 93.0 equipment is with a less-efficient motor and <br /> 50 92.4 93.0 93.0 92.4 93.0 93.0 there is no energy-eKcient motor option). <br /> 60 93.0 93.6 93.6 93.0 93.6 93.6 <br /> 75 93.0 94.1 93.6 93.0 94.1 93.6 For motors claiming an exception,list molor <br /> 100 93.0 94.1 94.1 93.6 94.5 94.1 and note which ezception applies. <br /> 125 93.6 94.5 94.1 94.5 94.5 94.1 <br /> 150 93.6 95.0 94.5 94 5 95.0 95D <br /> 200 94.5 95A 94.5 95.0 95.0 95.0 <br /> �1 � <br />