My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 RIVERSIDE RD COMPASS CANTEEN VENDING 2021-02-24
>
Address Records
>
RIVERSIDE RD
>
607
>
COMPASS CANTEEN VENDING
>
607 RIVERSIDE RD COMPASS CANTEEN VENDING 2021-02-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2021 1:44:20 PM
Creation date
2/24/2021 1:42:31 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
607
Tenant Name
COMPASS CANTEEN VENDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
410 • <br /> 607 Riverside Road <br /> B1909-009 <br /> City Review Comment Response <br /> 2. The "S-1"occupancy area shown in Egress Plan 1/A0.1 is anticipated to have high-pile storage. <br /> The exit doors shall be provided with both low and high exits signs to improve visibility. Where <br /> existing signs occur, they shall be indicated on the plans. See IBC Section 1013.1 and IEBC <br /> Section 801.3. <br /> Please see revised sheet A0.1 with revised exit legend and new general note: Racking solution is <br /> not known at this time - a separate, future racking permit will be submitted. Future racking permit <br /> will include additional exit signs required specific to racking layout. <br /> 3. Means-of-egress illumination shall be provided for the "S-1"occupancy area per IBC Section <br /> 1008.2. The construction drawings shall include a reflected ceiling plan indicating the egress <br /> lighting. The lighting shall specify a minimum 90-minute uninterrupted supply power per IBC <br /> Section 1008.3.4. Where existing systems occur, they shall be indicated on the plans. See IEBC <br /> Section 801.3. <br /> Warehouse lighting concept has been added, including egress lighting Please see revised sheet <br /> A0.1. <br /> 4. The "S-1"occupancy area requires a minimum of two exits per IBC Table 1006.2.1. Emergency <br /> means-of-egress illumination shall be provided for this area per IBC Section 1008.3. The <br /> construction drawings shall include a reflected ceiling plan indicating emergency egress <br /> lighting. The lighting shall specify a minimum 90-minute uninterrupted supply power per IBC <br /> Section 1008.3.4. Where existing systems occur, they shall be indicated on the plans. See IEBC <br /> Section 801.3. <br /> Warehouse lighting concept has been added, including egress lighting Please see revised sheet <br /> A0.1. <br /> 5. The "S-1"occupancy area requires a minimum of two exits per IBC Table 1006.2.1. The exterior <br /> landings providing egress for this area shall be provided with emergency lighting. The lighting <br /> shall specify a minimum 90-minute uninterrupted supply power per IBC Section 1008.3.4. See <br /> IBC Sections 1008.3.2 Item 5 and 1010.1.6. Where existing systems occur, they shall be <br /> indicated on the plans. See IEBC Section 801.3. <br /> Please see revised sheet A0.1, new keynote 14. <br /> 19-1011 I i <br /> g ac er peak-compasspermit review response letter draft <br />
The URL can be used to link to this page
Your browser does not support the video tag.