• <br /> 607 Riverside Road <br /> B1909-009 <br /> City Review Comment Response <br /> New wall type 9A has been created to include insulation and continued space. Please see <br /> revised sheet A2.1 and A8.1. <br /> c. First Floor Plan 1/A2.1 shows a concrete wall between Offices 118 and 119. The concrete <br /> wall does not have a thermal break with the exterior. The interior furring walls shall <br /> specify a minimum insulation of R-13 plus R-10 continuous. The walls should extend the <br /> full length of each side of the wall and wrap around the end. See Table C402.1.3. <br /> Clarifying wall types have been added. Extent of wall type has been increased to wrap around <br /> end of wall. Please see revised sheet A2.1 <br /> d. The Main Entrance at Reception Room 101 has stepped exterior concrete wall panels <br /> furred with non-bearing walls on the interior side. The furring walls do not overlap. The <br /> furring walls shall lap sufficiently to provide a minimum thickness of insulation over the <br /> ends of the concrete panels. <br /> (reply#8d) Please see revised sheet xx.x <br /> 9. First Floor Plan 1/A2.1 shows the new girts per Plan 1/S1.1 (i.e., "strongbacks"per Key Note 10 <br /> on Sheet A2.1). The girts are connected tight to the wall per Plan 1/S1.1, but shown outside <br /> the furring wall on Plan 1/A2.1. The girts shall shown tight to the wall, and the furring shall <br /> wrap around the girts to provide the required insulation. Note that a girt does not occur at <br /> Grid K per Plan 1/S1.1. See IBC Sections 107.2.1 and 1603.1, and WSEC-15 Section C402.1.1.1. <br /> Strongback locations have been corrected to sit tight against the exterior wall.Wall type 2 is <br /> corrected to wrap string back. Please see revised sheet A2.1 <br /> Miscellaneous: <br /> 10. Details 1/A8.1 and 6/A8.1 both appear to provide top and bottom wall connections for the <br /> interior non-bearing walls. It is not clear if the details are redundant or address different <br /> conditions. The requirements for the top-of-wall connection in both details is incomplete, <br /> especially for Detail 6. The brace size, spacing, and connections at each end shall be <br /> specified. The braces and connections shall be adequate to resist out-of-plane loading on the <br /> walls per IBC Section 1607.14. Note that Detail 1 appears to rely on transfer of loading <br /> through the T-bar of the acoustic ceiling system; the load path should be revised unless shown <br /> be analysis to be adequate. See IBC Section 107.2.1 and 1604.1. <br /> Please see revised sheet A2.2 and A8.1 as well as new structural calculations attached. <br /> 19-1011glacier peak-com ass ermit review response letter draft <br /> P P P P <br />