Laserfiche WebLink
• <br /> Mr. Drew Martin,PE,SE <br /> October 8,2019 <br /> 2190664.20 <br /> Page 3of3 <br /> Okm <br /> calculations is 5-1/8 inches. The required embedment shall be clarified to <br /> ensure the proper depth is achieved. <br /> Response: The minimum embedment has been increased to 5'/A." <br /> 5. Section 3/S1.1 shows the typical connection between orthogonal wall panels. <br /> Calculations substantiating the connection do not appear to be included in the <br /> calculation package and shall be submitted for review. Note that the connection will <br /> induce eccentric loads in the anchors. The anchors shall be designed for concurrent <br /> shear and tensile loading. See IBC Sections1604.1 and 1604.4. <br /> Response: This particular panel has four existing embed connections to tie the <br /> panels together. This is probably strong enough on itself not to require the added <br /> clips but is more costly to analyze at this point. The included calculation <br /> addendum has the eccentricity taken into account; and with the clips alone, it <br /> required adding two additional angle pieces to reduce the spacing to 4'-0"oc. <br /> If you have any questions, please call me at(253) 383-2422. <br /> Sincerely, <br /> Larry . H' gins, PE <br /> Senior Engineer <br /> LAH/el <br /> Enclosure <br /> c: Jessica Bradley—Nelson Worldwide <br /> Dan Booth-AHBL <br /> Q:\2019\2190664\WORDPROC\Letters\20191008 Ltr(Resp Bldg Rev 1)2190664.20.docx <br /> CMJCIBI <br />