Laserfiche WebLink
SHGC Calculation ENV-SHGC <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: ST.MARY MAGDALEN CHURCH Date 02/12/2019 <br /> Target Insulation Allowance: For Building Department Use <br /> Fully Conditioned Space-Commercial,Group R,Mixed Use <br /> Fenestration Area as%gross above-grade wall area 10.2% Max.Target: 30.0% <br /> Skylight Area as%gross roof area 0.0% Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included in this worksheet. User Note <br /> Enter target SHGC values for this fenestration under proposed SHGC,so it is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) =SHGC x P SHGC x Area(A)= SHGC x A <br /> 0.35 <br /> SHGC 0.35 <br /> Skylight Totals <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)=SHGC x A Category SHGC x Area(A)= SHGC x A <br /> First floor 0.55 162 89 pF<0.2 0.40 162 64.8 <br /> Clerestory 1.00 0.55 190 105 0.25PF<0.5 0.48 <br /> PF>_0.5 0.64 190 122 <br /> ++If projection factor(PF)credits are <br /> applied to the proposed design, Target <br /> SHGC will sum fenestration area by PF <br /> category. <br /> +If PF credit is applied,then vertical fenestration Non-North Window Totals 352.0 193.6 352.0 186.4 <br /> must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF SHGC x Area(A).SHGC x A PF SHGC x Area(A)= SHGC x A <br /> Sch.ID Provide SHGC source and fenestration schedule ID <br /> Category <br /> First floor 0.55 90 50 PF<0.2 0.53 90 47.7 <br /> Clerestory 1.00 0.55 160 88 0.25PF<0.5 0.58 <br /> PF 0.5 0.64 160 102 <br /> ++If projection factor(PF)credits are applied <br /> to the proposed design, Target SHGC will <br /> sum fenestration area by PF category. <br /> North Window Totals 250.0 137.5 250.0 150.1 <br /> TO COMPLY-The Proposed Total SHGC x A Area SHGC x A Area SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 602.0 331.1 I I 602.0 I 336.5 <br /> • <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br /> 677/) <br />