My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8615 7TH AVE SE 2021-02-26
>
Address Records
>
7TH AVE SE
>
8615
>
8615 7TH AVE SE 2021-02-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2021 10:31:46 AM
Creation date
2/26/2021 10:28:27 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
8615
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building Permit Plans Checklist, pg. 1 ENV-CHK <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: ST.MARY MAGDALEN CHURCH Date 02/12/2019 <br /> The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br /> Energy Code,Commercial Provisions. <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> SCOPE <br /> Identify low energy spaces on plans;include project information,and <br /> NA C402.1.1 Low energy spaces calculations if applicable,that demonstrate spaces are eligible for <br /> envelope provisions exemption <br /> NA C402.1.1.1 Semi heated spaces Identify semi-heated spaces on plans,include calculations that <br /> demonstrate spaces are eligible for wall insulation exemption <br /> Provide building area,average wall and roof U-factor,and installed <br /> NA C402.1.2 Equipment Buildings equipment information that demonstrates equipment building is eligible for <br /> envelope provision exemption <br /> Walk-in and <br /> NA C410.2 warehouse cooler Identify walk-in and warehouse cooler and freezer spaces on plans <br /> and freezer spaces <br /> NA C101.4.1 Mixed occupancy Identify spaces with different occupancy requirements on plans <br /> Identify on plans existing unconditioned spaces changing to semi-heated <br /> Change of space or conditioned space,and existing semi-heated spaces changing to <br /> NA C503.2 conditioning conditioned space;provide calculations for existing and final level of space <br /> conditioning,and calculations that demonstrate alteration complies with <br /> current WSEC <br /> Identify on plans existing F,S and U-occupancy spaces undergoing a <br /> change in occupancy;provide calculations that demonstrate alteration . <br /> complies with the current WSEC <br /> Change of Identify on plans pre-2002 Group R spaces undergoing a change to a <br /> NA C505.1 commercial occupancy;provide calculations that demonstrate alteration <br /> occupancy complies with the current WSEC <br /> Identify on plans non-Group R occupancy spaces undergoing a change to <br /> Group R;provide calculations that demonstrate alteration complies with <br /> the current WSEC <br /> ENVELOPE PROVISIONS <br /> indicate envelope insuiation compliance patn and provide appncaeie <br /> C103.2 Compliance forms;ENV-PRESCRIPTIVE or ENV-UA/ENV-SHGC for component <br /> YES C103.6.3 documentation oarformancp Attached <br /> If complying via total building performance,provide a list of all proposed <br /> envelope component types,areas and U-values <br /> C303.1.1 Insulation Indicate identification mark shall be applied to all insulation materials and <br /> YES insulation installed such that the mark is readily observable during A1.1 <br /> C303.1.2 identification <br /> inspection <br /> YES C303.1.3 Fenestration product Fenestration products shall be labeled with rated U-factor,SHGC,VT,and A9.1 <br /> C402.4.3 rating leakage rating <br /> Indicate installation methods,thicknesses,densities and clearances to <br /> C303.1.1 General insulation achieve the intended R-value of all insulation materials; <br /> YES C402.2.1 installation Where two or more layers of rigid insulation will be used,indicate that A8.0 <br /> edge joints between layers are staggered <br /> Indicate R-value(s)of cavity/continuous insulation on roof sections; <br /> Indicate framing materials on roof sections; <br /> Indicate method of framing for ceilings below vented attics and vaulted <br /> ceilings per A102.2(std,adv); <br /> YES C103.2 Roof assembly Provide area weighted average U-factor calculation for insulation whose <br /> C402.2.2 insulation thickness varies by 1 inch or less; A5.2,A5.3,A8.0 <br /> Indicate effective U-factors of tapered insulation entirely above deck per <br /> A102.2.6;include roof configuration and slope,maximum R-value at peak <br /> and minimum R-value at low point for all roof surfaces <br /> Indicate R-values for thermal spacers and each insulation layer,and liner <br /> system(LS)method for metal building roofs <br /> NA C402.2.2 Skylight curb Indicate curb insulation R-value on roof section if not included in skylight <br /> insulation NFRC rating <br /> Indicate R-value(s)of cavity/continuous insulation on wall sections; <br /> Indicate framing materials on wall sections; <br /> Indicate method of framing for wood construction per A103.2(std,int,adv); <br /> C103.2 <br /> YES C402.2.3 Above/below grade Indicate material density category,wall weight and heat capacity for A5.2,A5.3,A8.0, <br /> C402.2.4 wall insulation qualifying mass walls; S4.1 <br /> C303.2.1 For qualifying ASTM C90 masonry walls,indicate loose-fill core insulation <br /> material and percentage of cores filled including grouted cores,bond <br /> beams,vertical fills,headers and any other grouted cores; <br />
The URL can be used to link to this page
Your browser does not support the video tag.