2. The FW is required to provide a complete separation between the two portions of the <br /> building. The northern portion of the wall terminates at the exterior wall, however the <br /> roof overhang of the existing school building (at main entry doors) continues past the <br /> proposed end of the FW. The FW should therefore continue westward to at least the 90 <br /> degree juncture between the lower roof and new exterior wall. Section 706.1 <br /> a. The FW should continue in the western direction a minimum of 4 feet past the 90 <br /> degree juncture to avoid the issues created by compliance with Sections 706.5.1 <br /> & 706.5.2. Specifically, an additional wall would be required that would partially <br /> block the entry doors to the school, or the roof overhang causing the issue would <br /> have to be removed. <br /> 3. The upper roof of the new building continues past the fire wall with an overhang on the <br /> other side as shown in Wall Section 2/A5.4.The following options apply per Section 706.6: <br /> a. The FW should continue to a minimum of 30"above the roof on both sides, or <br /> b. The wood decking should be shown as fire-retardant-treated for a distance of 4 <br /> feet on either side of the wall (plus Class B roofing and no openings within 4' of <br /> the FW), or <br /> c. The roof/ceiling assembly should be protected for one-hour fire-resistance for 4 <br /> feet on either side of the wall (plus Class B roofing and no openings within 4' of <br /> the FW), or <br /> d. Remove the part of the roof that overhangs the school building and comply with <br /> Section 706.6.1 instead of Section 706.6. <br /> 4. The wheel chair lift appears to receive access through the FW, if so, a 90-minute door <br /> should be provided. Section 716.5 <br /> 5. The glazed openings within the fire wall as shown on the north elevation require 90- <br /> minute fire-resistive protection. <br /> 6. As the fire wall turns north from Grid Line B to Grid Line 8 it should continue vertically <br /> until the edge of the eave overhang. See exceptions in Section 706.5.2 <br /> Egress <br /> 1. The location and nomenclature of the maximum occupant load signs for the assembly <br /> spaces should be shown on the plans. Section 1004.3 <br /> 2. A sign stating Exit in raised characters and braille and complying with ICC A117.1 should <br /> be shown adjacent to the exterior exit doorways. Section 1013.4 <br /> 3. All of the exit doors should be shown with panic hardware on the door schedule. Section <br /> 1010.1.10 <br /> 4. The treads in Stair Detail 4/A8.6 should be shown to be a minimum of 11"of run. Section <br /> 1011.5.2 <br /> 5. Handrails should be detailed on the plans in accordance with Section 1014.6: <br /> �/ <br /> n 3200 Cedar Street Q 425.257.8810 0 tlee@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.