My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8615 7TH AVE SE 2021-02-26
>
Address Records
>
7TH AVE SE
>
8615
>
8615 7TH AVE SE 2021-02-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2021 10:31:46 AM
Creation date
2/26/2021 10:28:27 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
8615
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r M. <br /> Botesch, Nash & Hall <br /> Architects, P.S. <br /> r FIT <br /> ' 1 <br /> April 29, 2019 A\ MAY <br /> ATTN: Building Department 2 9 2019 <br /> City of Everett crry OF EVERETT <br /> RE: St. Mary Magdalen Church <br /> Permit Services <br /> 8615 7th Ave. SE <br /> B 1902-008 <br /> NON STRUCTURAL: <br /> General: <br /> 1) The NFPA-72 Fire Alarm should also be included in the deferred submittals. <br /> Section 107.3.4.1 . <br /> Sheet G 1.0 - Add Fire Alarm to Deferred Submittals list. <br /> 2) Although this is a church use, alterations to the electrical system within <br /> and/or tied to the school portions of the building will require and electrical <br /> plan review. Additionally, as the service appears to be within the school <br /> portion of the building, the plan review will include the electrical system as <br /> well. This review may be initiated with an electrical permit application, two <br /> sets of plans and load calculations for all altered and/or new loads and <br /> effected feeders and service stamped by an electrical engineer licensed by <br /> the state of Washington. WAC 296-46b-900. <br /> Sheet G1 .0 - Add "ELECTRICAL" to deferred submittals. <br /> Electrical drawings will be submitted as part of a separate submittal <br /> General: <br /> 1) The type of construction for the school building should be provided. The fire <br /> wall (FW) will be required to be 3-hour, noncombustible construction if the <br /> school building is not Type V construction. Footnote A to table 706.4. <br /> Both the school and church are constructed of brick walls, steel columns and <br /> wood beams and wood decking which is VB construction type. <br /> Sheet AS1 .0 - Add "TYPE VB CONSTRUCTION" to the school and church <br /> labels on the site plan <br />
The URL can be used to link to this page
Your browser does not support the video tag.