e TWO, ! rr <br />Per;' <br />STRUCTURAL NOTES <br />1.0 GENERAL NOTES <br />THESE STRUCTURAL NOTES SUPPLEMENT THE DRAWINGS. ANY DISCREPANCY FOUND <br />AMONG THE DRAWINGS. THESE NOTES, AND THE SITE CONDITIONS SHALL BE <br />REPORTED TO THE ENGINEER WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. <br />ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY <br />SHALL BE DONE AT THE CONTRACTOR'S RISK THE CONTRACTOR SHALL VERIFY AND <br />COORDINATE THE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH <br />ANY WORK OR FABRICATION. THE CONTRACTOR IS RESPONSIBLE FOR ALL BRACING <br />AND SHORING DURING CONSTRUCTION. <br />1.1 SIODERS WARRANTY <br />BY THE ACT OF SUBMITTING A BID FOR THE PROPOSED CONTRACT, THE <br />CONTRACTOR WARRANTS THAT: <br />A THE CONTRACTOR AND ALL SUBCONTRACTORS HE INTENDS TO USE HAVE <br />CAREFULLY AND THOROUGHLY REVIEWED THE DRAWINGS AND STRUCTURAL NOTES <br />AND HAVE FOUND THEM COMPLETE AND FREE FROM AMBIGUITIES AND SUFFICIENT <br />FOR THE PURPOSE INTENDED; FURTHER THAT, <br />B. THE CONTRACTOR HAS CAREFULLY EXAMINED THE SITE OF THE WORK AND THAT <br />FROM HIS OWN INVESTIGATIONS, HE HAS SATISFIED HIMSELF AS TO THE NATURE <br />AND LOCATION OF THE WORK, AS TO THE CHARACTER, QUALITY. QUANTITIES OF <br />MATERIAL AND DIFFICULTIES TO BE ENCOUNTERED, AS TO THE EXTENT OF <br />EQUIPMENT AND OTHER FACILITIES NEEDED FOR THE PERFORMANCE OF THE WORK <br />AND AS TO THE GENERAL AND LOCAL CONDITIONS, AND OTHER I7EMS WHICH MAY IN <br />ANY WAY AFFECT THE WORK OR ITS PERFORMANCE. FURTHER THAT. <br />C. THE CONTRACTOR AND ALL WORKMEN HE INTENDS TO USE ARE SKILLED AND <br />EXPERIENCED IN THE TYPE OF CONSTRUCTION REPRESENTED BY THE DRAWINGS <br />AND DOCUMENTS BID UPON; FURTHER THAT. <br />D. NEITHER THE CONTRACTOR NOR ANY OF HIS EMPLOYEES, AGENTS, INTENDED <br />SUPPLIERS, OR SUBCONTRACTORS HAVE RELIED UPON ANY VERBAL <br />REPRESENTATIONS ALLEGEDLY AUTHORIZED OR UNAUTHORIZED FROM THE OWNER <br />OR HIS EMPLOYEES OR AGENTS, INCLUDING THE ARCHITECT OR ENGINEERS, IN <br />ASSEMBLING THE BIO FIGURES; FURTHER THAT, <br />E. THE BID FIGURE IS BASED SOLELY UPON THE CONSTRUCTION CONTRACT <br />DOCUMENTS AND PROPERLY ISSUED WRITTEN ADDENDA AND NOT UPON ANY <br />/ 1.2 CODES <br />A ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2015 <br />1 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND ADOPTED BY THE LOCAL <br />BUILDING AUTHORITY. <br />B. ALL REFERENCE TO OTHER CODES, ACI, ASTM ETC., SHALL BE FOR LATEST OR MOST <br />CURRENT EDITION AVAILABLE <br />1.3 UNIFO O - _ / <br />WAS$ UVELOAD <br />1.4 SOIL DATA " <br />$01 DENSITY =120 PCF <br />ALLOWABLE BEARING PRESSURE • 6000 PSF <br />1 COEFFICIENT OF FRICTION - 0.50 <br />LATERAL ACTIVE EARTH PRESSURE - 35 PSF <br />LATERAL AT -REST EARTH PRESSURE - 55 PCF <br />PASSIVE EARTH PRESSURE - 300 PCF <br />SEE SUBSURFACE EXPLORATION AND GEO TECHNICAL ENGINEERING REPORT BY <br />ROBINSON NOBLE ENGINEERING. ALLOW 33.113% INCREASE FOR LOADS FROM WIND OR <br />SEISMIC ORIGIN. <br />1.6 SHOP DRAWINGS <br />THE ENGINEER OF RECORD SHALL REVIEW SHOP DRAWINGS FOR DESIGN (WENT ONLY. <br />THE ENGINEER OF RECORD DOES NOT GUARANTEE DIMENSIONS AND QUANTITIES; <br />THEREFORE, THE GENERAL CONTRACTOR MUST VERIFY THEM. DRAWINGS FOR <br />COMPONENTS DESIGNED PRIMARILY BY OTHERS SHALL BE APPROVED BY THE <br />COMPONENT DESIGNER PRIOR TO CURSORY REVIEW BY THE ENGINEER OF RECORD <br />FOR LOADS IMPOSED ON THE BASIC STRUCTURE. THE COMPONENT DESIGNER IS <br />RESPONSIBLE FOR CODE CONFORMANCE AND ALL NECESSARY CONNECTIONS NOT <br />SPECROALLY CALLED OUT ON ARCHITECTURAL OR STRUCTURAL DRAWINGS. SUBMITA <br />REPRODUCIBLE AND FIVE COPIES OF THE SHOP DRAWINGS TO THE ARCHITECT OR <br />ENGINEER. THE REPRODUCIBLEWILL BE REVIEWED AND RETURNED. ALLOWIO <br />WORKING DAYS FOR REVIEW. SHOP DRAWINGS SHALL BE SUBMITTED FOR THE <br />FOLLOWING: <br />A REINFORCING STEEL <br />SHOP DRAWINGS MUST BE REVIEWED AND STAMPED BY THE CONTRACTOR PRIOR TO <br />SUBMISSION AND REVIEW BY THE ENGINEER <br />1.7 MISCELLANEOUS <br />A. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. <br />B. VERIFY SIZE AND LOCATIONS OF ALL OPENINGS IN THE FLOORS, ROOF AND <br />WALLS WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. <br />C. CONSTRUCTION DETAILS NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL <br />FOLLOW SIMILAR DETAILS OF SECTIONS OF THIS PROJECT AS APPROVED BY THE <br />ARCHITECTIENGINEER, <br />2.0 SITE WORK <br />7-1 EXCAVATION <br />EXCAVATE FOOTINGS DOWN TO DEPTH ON DRAWINGS OR TO FIRM UNDISTURBED <br />MATERIAL. AREAS OVER -EXCAVATED SHALL BE SACKFILLED WITH LEAN CONCRETE <br />(F'.-2DDD PSI), AND SHALL BE AT THE CONTRACTORS EXPENSE EXERCISE EXTREME <br />CARE DURING EXCAVATION TO AVOID DAMAGE TO BURIED LINES, TANKS AND OTHER <br />CONCEALED ITEMS. UPON DISCOVERY. DO NOT PROCEED WITH WORK UNTIL <br />RECEIVING WRITTEN INSTRUCTIONS FROM ARCHITECT. PROVIDE DRAINAGE AS <br />NECESSARY TO AVOID WATER SOFTENED SUBGRADEB. <br />2.2 BACKFILL AND COMPACTION <br />BACKFILL AGAINST WALLS SHALL NOT BE PLACED UNTIL AFTER THE REMOVAL OF ALL <br />FORMS, SCREEDS, OTHER WOOD DEBRIS AND MATERIAL SUBJECT TO ROT OR <br />CORROSION, USE ONLY MATERIALS APPROVED FOR BACKFI-L. IN AREAS UNDER <br />SLABS OR FOOTINGS, MATERIAL OTHER THAN PEA GRAVEL SHOULD BE GRANULAR IN <br />NATURE, PLACED IN S INCH LIFTS AND COMPACTED TO AT LEAST 95%OF ITS MAXIMUM <br />DRY DENSITY AS DETERMINED BY AASHTO COMPACTION TEST PROCEDURE T-160. THE <br />FILL SHOULD BE LIMITED TO CLEAN, GRANULAR MATERIAL. PEA GRAVEL- FILL WHERE <br />SPECIFIED ON DRAWING$ SHALL HAVE A MAXIMUM PARTICLE SIZE OF 31W DIAMETER. <br />0, <br />3.0 STRUCTURAL CONCRETE <br />3.1 GENERAL <br />ALL CONCRETE SHALL MEET REQUIREMENTS FOR'ULTIMATE STRENGTH TYPE <br />CONCRETE". PER ACI-301. AND "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR <br />BUILDINGS". PROPORTIONING OF INGREDIENTS FOR EACH CONCRETE MM SHALL BE <br />BY METHOD 2 OR THE ALTERNATE PROCEDURE (306) FOR WINTER CONCRETING AND <br />AC1405 (305) FOR HOT WEATHER CONCRETING. USE INTERIOR MECHANICAL <br />VIBRATORS WITH 7ODD-RPM MINIMUM FREQUENCY. DO NOT OVER -VIBRATE. CONCRETE <br />SHALL BE PLACED MONOLITHICALLY BETWEEN CONSTRUCTION OR CONTROL JOINTS. <br />PROTECT ALL FRESHLY PLACED CONCRETE FROM PREMATURE DRYING EXCESSIVE <br />HOT OR COLD TEMPERATURE FOR SEVEN DAYS AFTER POURING. PROVIDE <br />ARCHITECTIENGINEER WITH PROPOSED CONSTRUCTION OR CONTROL JOINT <br />LOCATIONS FOR THEIR APPROVAL. 3.2 STRENGTH <br />TWENTY-EIGHT DAY COMPRESSIVE STRENGTHS SHALL BE: <br />PSI SLUMP <br />VERTICALLY FORMED WALLS 2500 3"+/-1" <br />FOOTINGS 2500 4"+/-1" <br />THESE SLUMPS MAY BE INCREASED IF A PROPER ADDITION OF ADMIXTURE OR <br />ADMIXTURES IS ADDED TO ALLOW HIGHER SLUMP AND GREATER WORKABILITY <br />WITHOUT CHANGING THE WATER CONTENT OF THE ORKHNALAPPROVED MIX DESIGN. <br />ADMIXTURES CONTAINING CHLORIDES ARE NOT PERMITTED UNLESS APPROVED BY <br />THE ENGINEER. <br />3.3 MATERIALS <br />A CEMENT MUST CONFORM TO ASTM 150, TYPE 1 OR TYPE 141. <br />0 COARSE AND FINE AGGREGATE TO CONFORM TO ASTM C33 <br />3.4 WATER REDUCING ADMIXTURES <br />A WATER REDUCING ADMIXTURE: MUST CONFORM TO ASTM C494. ADMIXTURES <br />SHALL BE INCORPORATED INTO ALL CONCRETE IN EXACT ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />S. SYNERGIZED PERFORMANCE SYSTEMS: CONCRETE USING ADMIXTURES TO <br />PRODUCE FLOWABLE CONCRETE MAY BE USED WITH ENGINEER'S APPROVAL DESIGN <br />SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL. <br />C. AIR ENTRAINMENT: CONFORMED TO ASTM C260 AND ASTM C494, ENTRAIN 5%*1% <br />BY VOLUME IN ALL EXPOSED CONCRETE. <br />0. NO OTHER ADMIXTURES PERMITTED UNLESS APPROVED BY THE ENGINEER <br />5 REINFORCING STEEL <br />A DEFORMED BAR REINFORCEMENT: ASTM A-615-GR 60 <br />e. WELDED DEFORMED BAR REINFORCEMENT: ASTM A706 OR 60 OR ASTM AS15 GR <br />40 <br />C. WELDED WIRE FABRIC: ASTM A-185 & ASTM A-2 <br />D. DEFORMED BAR ANCHORS: ASTMA-496 <br />NAIL, FABRICATE, AND PLACE PER ACI-316 ANDACM318. SUPPORT REINFORCEMENT <br />WITH APPROVED CHAIRS. SPACERS, OR TIES. <br />3.8 FORMWORKANO SHORING <br />0. FOLLOW RECOMMENDED PRACTICES FOR CONCRETE FORMWORK(ACI-347). <br />B. ALL SHORING $HALL BE THE RESPONSIBILITY OF THE CONTRACTOR. FORMWORK <br />SUP ORT5 AND SHORING SHALL BE DESIGNED TO PROVIDE FINISHED CONCRETE <br />SU AT ALL FACES LEVEL, PLUMS AND TRUE TO THE DIMENSIONS AND <br />I N C O R P O RA2'8D <br />STRUCTURAL & CIVIL <br />ENGINEERS <br />1235 EAST 4TH AVE. <br />SUITE 101 <br />OLYMPIA, WA 98506 <br />T (360) 754-9339 <br />F (360) 352-2044 <br />www.mc2-inc.com <br />to <br />a <br />CONC TE COVER ON REINFORCING (UNLESS SHOWN OTHERWISE) <br />80T M OF FOOTINGS 3' <br />MEO EARTH FACE & SLAB ON GRADE 2" <br />&7 CONSTRUCTION JOINTS <br />UNLESS NOTED OTHERWISE, LOCATION OF THE CONSTRUCTION OR CONTROL JOINTS IN <br />SLAB ON GRADE SHALL BE COLUMN GRIDS OR UNDER PERMANENT PARTITIONS AMID <br />SHALL NOT EXCEED W EACH WAY. <br />&0 METALS <br />&1 WELDING <br />A ALL WELDING SHALL BE IN ACCORDANCE WITH THE "STRUCTURAL WELDING <br />CODE", AWS D1.1. <br />S. ALL WELDING SHALL BE BY CERTIFIED WELDERS, USING E70 ELECTRODES. <br />C. NO WELDING OF REINFORCING STEEL SHALL BE ALLOWED EXCEPT WHERE <br />O <br />0 <br />SHOWN. ALL WELDING OF REINFORCEMENT SHALL BE PER AWS 012.1 <br />, <br />' <br />S.2 STRUCTURAL STEEL <br />A ALL DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO THE MSC, <br />"MANUAL OF STEEL CONSTRUCTION:, LATEST EDITION. <br />v V <br />B. STEEL SHAPES AND PLATES SHALL BE ASTM A-992( Fy - 50 KSI) <br />C. BOLTS SHALL BE ASTM A325N. <br />D. METAL PROTECTION: ALL STEEL EXPOSED TO WEATHER, MOISTURE, SOIL, OR AS <br />NOTED SHALL BE GALVANIZED PER ASTM A-123 WITH 1.25 OZ. OF ZINC SPELTER PER <br />SQUARE FOOT OF SURFACE AREA ALL OTHER STEEL SURFACES TO BE SHOP <br />PAINTED AFTER FABRICATION. <br />RE <br />CLH <br />MS <br />09-27-18 <br />18502 <br />S1.0 <br />1 Of 4 <br />