Laserfiche WebLink
Project: liver Plaza Retail Building <br />Number: 215 <br />El Location: Everett, WA <br />City Response Letter <br />rJ4te:__, 07-17-2017 <br />To: Meg Haley, Associate Engineer -Plan Review Architect 425-257-88136 #1 Z <br />From: Larz Hitchcock, Architect/ LEED AP (BD+C) (( <br />VE <br />Re: Everett Retail Silver Plaza Building— Response for Building Review 1 (B1703-024) JUL 2 8 2ol? <br />Meg PI i Y OFE VERETT <br />Thank you for your time and consideration in your review of our clients' project. This letter is foPW 44lalrvices <br />response to the commentary of your letter dated June 16`h, 2017. We have copied these comments and our <br />responses are given after each in blue text. <br />General: <br />1. Please identify all exterior signage (except building number and accessible parking signage) as being a <br />deferred submittal. <br />Life safety signage is included and as shown. Way finding and other signage will be deferred. <br />Ref. G201, A100 and 4/A102 <br />Occupancy, <br />1. Please summarize total occupant load count by occupancy and floor area, per IBC table 1004.1.2. <br />a. The occupant load factors on G201 appear to be representing zoning calculations, not building code <br />occupancy loads. <br />We concur - Ref. revised G201 for details <br />b. The areas on sheet G201 do not appear to correspond with areas on sheet G200. <br />We Concur - Ref. revised G200 <br />c. Please identify the area of the restaurant separately from the covered outdoor area. <br />We Concur - The covered outdoor area (Patio) is part of the restaurant. <br />d. Please indicate if the covered outdoor area will exit directly or will be contained to exit to the interior of <br />the restaurant. <br />The exiting from the restaurant was previously shown to this enclosed area. This was incorrect and has <br />been revised. The covered outdoor area (Patio) will be contained to exit to the interior of the restaurant <br />for security reasons. <br />v 2. Please show the following on the drawings: <br />a. Specific signage at the main entrance door and the exit doors to indicate that these doors will be open <br />during business hours, per IBC section 1010.1.9.3, item 2.2. <br />We Concur - Ref. revised A601 <br />b. The door schedule should indicate that any locking devices on these doors are readily distinguishable as <br />being locked. <br />We Concur — Ref. revised A601 <br />Fire Resistance, Egress and Life Safety <br />Jensen / Fey Architecture and Planning <br />7730 Leary Way Redmond, WA 98052 <br />T. 425 216 0318 F: 425 216 0329 www.jensenfey.com <br />