My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE 2022-05-23
>
Address Records
>
19TH AVE SE
>
10521
>
10521 19TH AVE SE 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 1:22:25 PM
Creation date
2/26/2021 2:35:12 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
412
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Report <br />Mixed -Use Everett <br />10521-191h Ave. SE <br />Everett, Washington <br />March 23, 2016 <br />RN File No. 3109-001A <br />Page 7 <br />rest earth pressure can be calculated based on equivalent fluid density. Equivalent fluid <br />densities for active and at -rest earth pressure of 35 pounds per cubic foot (pcf) and 55 pcf, <br />respectively, may be used for design for a level backslope. These values assume that the on - <br />site soils or imported granular fill are used for backfill, and that the wall backfill is drained. The <br />preceding values do not include the effects of surcharges, such as those due to foundation <br />loads or other surface loads. Surcharge effects should be considered where appropriate. <br />Seismic lateral loads are a function of the site location, soil strength parameters and the peak <br />horizontal ground acceleration (PGA) for a given return period. We used the US Geological <br />Survey program "2008 PSH Deaggregation on NEHRP" to compute the PGA for the site. The 3- <br />D histogram is included in Appendix A. The PGA for the active condition was reduced by one- <br />half, referenced in Geotechnical Earthquake Engineering by Steve L Kramer, 1996. When <br />considering seismic conditions, the above drained active and at -rest values should be increased <br />as shown in the table below. H represents the wall height. <br />Seismic Surcharge Loads <br />Probability of Exceedance (Recurrence Interval) <br />20% in 50 years (1 in 224 year) <br />10% in 50 years 0 in 475 year) <br />Acceleration (g) <br />0.26 <br />0.39 <br />Active > 0.001 H <br />5H <br />8H <br />Non -Yielding <br />5H <br />10H <br />The above lateral pressures may be resisted by friction at the base of the wall and passive <br />resistance against the foundation. A coefficient of friction of 0.5 may be used to determine the <br />base friction in the native glacial soils. An equivalent fluid density of 300 pcf may be used for <br />passive resistance design. To achieve this value of passive pressure, the foundations should be <br />poured "neat" against the native dense soils, or compacted fill should be used as backfill <br />against the front of the footing, and the soil in front of the wall should extend a horizontal <br />distance at least equal to three times the foundation depth. A resistance factor of 0.67 has <br />been applied to the passive pressure to account for required movements to generate these <br />pressures. <br />All wall backfill should be well compacted. Care should be taken to prevent the buildup of <br />excess lateral soil pressures due to overcompaction of the wall backfill. Hand compaction <br />equipment of a small roller should be used directly adjacent to the wall. <br />Slabs -On -Grade <br />Slab -on -grade areas should be prepared as recommended in the Site Preparation and Grading <br />subsection. Slabs should be supported on medium dense or firmer native soils, or on structural <br />fill extending to these soils. Where moisture control is a concern, we recommend that slabs be <br />underlain by 6 inches of pea gravel for use as a capillary break. A suitable vapor barrier, such as <br />Robinson Noble, Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.