Laserfiche WebLink
• • <br /> Interior Lighting Summary - Space-By-Space LTG-INT-SPACE <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address Camelot Apartments Leasing Office Date 5/20/2020 <br /> Lighting Alterations,Renovations & Building Additions For Building Department Use <br /> 0 Less than 60% Q 60%or more 0 Stand alone 0 Addition <br /> fixtures replaced fixtures replaced bldg. addition combined w/exist <br /> Notes: <br /> a. Lighting fixtures in a building addition may comply as a stand alone project,or they maybe <br /> combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. <br /> b. For retrofits and building additions,provide Space Types and gross interior areas in the <br /> Maximum Allowed Lighting table. If a builidng addition will comply as combined with the <br /> overall <br /> existing builidng, include all applicable existing Space Types and gross interior areas. <br /> c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d. if less than 60%of existing fixtures will be replaced,provide total existing lighting wattage <br /> (pnor to retrofit)in the space provided in the Maximum Allowed Lighting table. <br /> Maximum Allowed Lighting Wattage <br /> Location(plan#, Allowed Gross Interior Watts Allowed <br /> room#) Space Type* Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> Break Room Food preparation 0.99 319 316 <br /> Mail Room Conference/meeting/multipurpose 1.23 406 499 <br /> Atrium** Enter Height: <br /> Existing Lighting Enter Exist.Watts: <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> * Select Table C405.5.2(2)category from drop down menu. Area Allowed Watts <br /> ** For atriums,indicate height.Allowed wattage for first 40 feet is 0.03 W/ft.ht., Total 725 815 <br /> above 40 feet is 0.02 W/ft.ht. <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description*** Fixtures Fixture Proposed <br /> Break Room Existing 6"Recessed Can 4 26 104 <br /> Break Room New 6"Recessed Can 3 26 78 <br /> Mail Room Existing Pendant 1 36 36 <br /> Mail Room Relocated Pendant 1 36 36 <br /> Mail Room New 8"Recessed Can 8 26 208 <br /> Mall Room Exit 1 5 5 <br /> Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 467 <br /> ***Include existing to remain lighting fixtures and exempt lighting equipment per notes below. <br /> Notes: <br /> 1. Include ALL proposed lighting fixtures. <br /> 2. For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8), number of lamps in the fixture,and ballast type(if included). For <br /> track lighting, list the length of the track(in feet)in addition to the fixture, lamp, and ballast information. <br /> 3. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1. For line voltage track lighting,list the greater of actual luminaire wattage or length of track multiplied by 50, <br /> or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. <br /> 4. For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank. <br /> 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture <br /> description. <br /> R IfilN4 appParc in RPtaii rbcplayrallS informatinn fin I TP..INT-r)I.CRI AV is inrnmplata <br /> Interior Lighting Power Allowance COMPLIES <br />