Laserfiche WebLink
verizon‘f <br /> THIS DRAWING WAS PREPARED SOLELY FOR THE USE <br /> OF VERIZON WIRELESS AND MUST ONLY BE USED BY <br /> VERIZON WIRELESS EMPLOYEES,CONTRACTORS,AND <br /> VENDORS WHILE PERFORMING THE WORK SHOWN CN <br /> THIS DRAWING.ANY OTHER USE OF THIS DRAWING IS <br /> FORBIDDEN. <br /> II <br /> "a <br /> E MORRISON HERSHFIELD <br /> 600 STEWART STREET,SUITE 200 <br /> SEATTLE,WA 98101 <br /> PHONE:206268.7370 <br /> www.monisonhershfield.com <br /> DO NOT SCALE DRAWINGS. CONTRACTOR MUST <br /> — VERIFY AU.DIMENSIONS AND ADVISE CONSULTANTS <br /> '" OF ANY ERRORS OR OMISSIONS.NO VARIATIONS OR <br /> MODIFICATIONS TO WORK SHOWN SHALL BE <br /> IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL <br /> ALL PREVIOUS ISSUES OF THIS DRAWNG ARE <br /> SUPERCEDED BY THE LATEST REVISION. ALL <br /> DRAWNGS AND SPECIFICATIONS REMAN THE <br /> PROPERTY OF MORRISON HERSHFIELD <br /> CORPORATION. <br /> NEW ILC POWER PANEL (PANEL ILC) 400A, 120/240V-10-3W, 400A M.C.B. Q <br /> BUS SUS VA <br /> i> A S WAS VIRE ONO CORD AMPS B A Iu6 AIDE cow meumLOAD A 8 <br /> 1786 -- RE MEW Tow#1 00 %10 3/4 30'1-•— 2 90 1-1/2' #8 #2 NEW WARVA9t 7.5-ON AVIDA90 5748 <br /> - 1786 3 • 4 WPC 0 •• --_: 5748 <br /> 1786 —---:ME NEICIIFlER#2 00 #10 3/4 30 5 • 6 90 1-1/i #6 #2 NEW ILMW 1R 7.5-TON AVIDA90 [5748 W <br /> 1786 7 • 6 WPC#2 (NON-CONCuRRDIT TWO) 5748) Z <br /> 1786 =_-=NEW RECIIFER#3 #10 #10 3/4• 30 ---•--IC - - - - SPACE _ _ _ a 0 <br /> 1786 11 ---•-12 20 3/4 #12 #12 NEW RECEPTACLES- EGUP. RM. 540 - ;°M --U <br /> ct <br /> 1786 __ NEW RECTFER#4 #10 #10 3/4• 30 13 «••-14 20 3/4 #12 #12 Mt EXHAUST FAN 180 CD P- <br /> 1786 is ---�• 16 20 3/4 #12 #12 NEN INTERIOR UGHTS - EOUP. RM `4?-587 O - 0 m <br /> 1786 .__-_ NEW RECTPER#6 #10 #10 3/4 30 17 -•--18 20 3/4 #12 #12 NEW INTERIOR LIGHTS- GEN.IM. 458 0" Z a n <br /> ao <br /> _ - 1786 19 —•-20 20 3/4. #12 #12 NEW RECEPTACLES- EQUIP. Rm. 540 c8% Fa-- <br /> 1786 `NEW RECTIFER 0 #10 #10 3/4 30 21 •• 22 20 3/4 #12 #12 HEW RECEPTACLES- EalP. RM. 540 z m Cr) <br /> 1786 23 •• 24 20 3/4 #12 #12 NEN RECEPT CLES- GEN. m 720 ■I� p z I-- L>J <br /> - -- ::-:FUTURE RECIFIER#7 - - - 30 23 -•--26 20 3/4 #12 #12 NEW TELCO on RECEPTACLE 180 I. p w w - <br /> 27 —•-28 20 3/4• #12 #12 NEW EXIERIoR CFI RECEPTACLE 180 <br /> JO � N > <br /> FUTURE ROCIFER#8 - - - 30 26 ••--30 20 3/4 #12 #12 NEW GENERATOR BLOCK MUTER 1200 _ - - a W w <br /> - 31 • 32 20 3/4 #12 #12 NEW GENERATOR BAIT.CHARGER 1000 10 w > <br /> - MUTE RECTIFIER#9 - - - 30 33 ---34 20 - - - SPARE > m Q <br /> - 35 ---•-36 20 - - - SPARE <br /> FUTURE RE TEEN#10 - - - 30 37 -•—38 20 - - -- SPARE L!J <br /> - <br /> -• 39 K 40 - - - - SPACE w.__ - CO <br /> - -__ -_=SPACE - - - - 41 -•—42 - - - - SPACE - - <br /> - - FUTURE PANEL PPt ••"• - - - 200 K 200 - - - FUTURE PANEL PP2•M• - <br /> SF1 "2 <br /> TOTAL VA:BUS A 19022 eus a 20031 CONNECTED VA. 39053 Wes: BUS A 159 BUS a 167 TOTAL 163 <br /> ..... RATED VOLTAGE CI 120/208 • 120/240 CI 277/480 1 PHASE,3 NNE I BRANCH POLES 0 12 ❑18 020 ❑24 030 038 1142 <br /> RATED AIDS: 0 100 0 200 ■ 400 I CATRET • SURFACE CI FLUSH REV f DESCRIPTION DATE <br /> FLAT Nf:1RRAL sus III GROUND BUS I II WOOED DOOR I r KETED DOOR LATa1 I ENCLOSURE TYPE NEMA-1 A �RE-ISISSUESUED <br /> FOR 90%%SUBNWUEMITTAL 0829101] <br /> B j REISSUED FOR 90%SUBMITTAL 11222017 <br /> BRANCH DEVICES 0 FUSED ■ cRaAT BREAKER I <br /> 0 MAIL WC ONLY I MIN 4GOA ■BREAM CI FUSED S� I C ?ISSUED FOR PERMIT <br /> SUBMITTAL 02.072018' <br /> 0 �IS.SUED FOR PERMIT 02.072018 <br /> ALL BREAKERS MUST BE RATED TO MERRUPT A SHCRT CIRCUIT CURRENT OF MINIMUM MI 42.000 AMPS SYIRETRICC& i <br /> ACCEPTABLE MANUFACNRFR/YODEL: INTERSECT MODEL:AA400G-TP-200SF2 I 1 <br /> a'•-BREAKER SHOWN IS AN INTEGRAL SUB-FEED CIRCUIT BREAKER INTHE INTERSECT INTEGRATED LOAD CENTER(LC) NETNORK COMPLIANCE SUBMITTALS ' DATE <br /> PANEL ILC IS INCORPORATED INTO THE INTEGRATED LOAD CENTER(ILC). PREUMINARY SUBMISSION . <br /> ALL UNUSED BREAKERS TO BE LABELED"SPARE' 30%SUBMISSION <br /> THE LC HAS AN INTEGRAL TVSS CONNECTED TO THE UNE SIDE OF TIE LOADCENTER.THEREFORE.NO BRANCH CIRCUIT BREAKER IS FURNISHED FOR TVSS IN LOADCENTER. 60%SUBMISSION . <br /> M A.ONLY(1) HVAC UNIT WILL RUN AT ONE TIME VIA THE LEAD/LAG CONTROLLER 90%SUBMISSION 11.222017 <br /> 100%SUBMISSION 01.052018 <br /> ORIGNAL ISSUE . <br /> ISSUED FOR CONSTRUCTION . <br /> -- ISSUED FOR PERMIT 02.072018 <br /> .- RECORD SET(AS-BULTS) <br /> PROJECT NO STAMP <br /> 7170182 _c,\5. L(Y, <br /> CAD DWGFLE: /� 01 lJij7,C,� <br /> DESIGNED BY: FA `// - <br /> DRAWN BY: LP 7 ,��:'f, <br /> CHECKED BY: RL 7 F_�.p7,525113\�,e <br /> i, COPYRIGHT: 201: i)Q18S5�:gc0 I I <br /> �q{ <br /> SHEET TITLE <br /> "l yS PANEL <br /> SCHEDULE <br /> PANEL SCHEDULE 1 SHEET NUMBER <br /> E601 <br /> v <br />