My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 RIVERSIDE RD AMAZON 2021-04-01
>
Address Records
>
RIVERSIDE RD
>
607
>
AMAZON
>
607 RIVERSIDE RD AMAZON 2021-04-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2021 12:14:05 PM
Creation date
4/1/2021 12:09:13 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
607
Tenant Name
AMAZON
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> 8. The Ceiling Plan on Sheet A2.01 specifies the location of exit signs. See IBC Section 1013.1. <br /> The following comments shall be addressed: <br /> a. The space includes tall storage racks and equipment that may obscure the visibility of <br /> exit signs located directly above the doorways. The plan shall specify that the signage <br /> at the doors will include both low and high exit signs to improve visibility. Notes and <br /> additional exit signs will be added to the E2.00 series drawings to comply with this <br /> requirement. <br /> b. The interior exit signs indicate directions to exit doors that are blocked by fences or <br /> other obstructions. Examples include, but are not limited to, the signs at Grids B.4/2.7, <br /> C.7/3.3, E.4/3.3, and G.2/3.3. The location and directions for the exit signs shall be <br /> revised. Additional signs shall be provided as needed to clearly indicate the locations of <br /> and paths to the exits. Exit signs indicated in the comment are provided on the "green <br /> mile"which is a clear path for personnel to travel. No obstructions are anticipated along <br /> this path. <br /> c. The exit sign at Grid C.7/3.3 directs occupants toward the exit located within Room 302. <br /> An additional exit sign shall be provided outside Door 302. An additional exit sign will be <br /> provided outside door 302 on E2.01. <br /> d. The distance between exit signs appears to exceed 100 feet at multiple locations. The <br /> sign layout shall be revised as needed. Notes and additional exit signs will be added to <br /> the E2.00 series drawings to comply with this requirement. <br /> Miscellaneous: <br /> 9. The partition sections on Sheet G0.03 indicate many of the partitions do not extend to the <br /> roof deck above. A detail shall be included providing top-of-partition bracing. Calculations <br /> shall be submitted review substantiating that the bracing is adequate for a minimum 5 psf <br /> out-of-plane load on the partitions. See IBC Section 107.2.1, 1604.1, and 1607.14. <br /> BL Response: Calculations and details will be provided by the general contractor's light <br /> gauge metal framing sub-contractor as a deferred submittal. <br /> 10.The project includes CMU walls around the scrubber dump at Grid C.2/2.3, as shown in <br /> Section 3/A4.02. See IBC Section 107.2.1. The following comments shall be addressed: <br /> a. The vertical wall reinforcement for the walls appears to conflict, specifying bars at both <br /> 12-inch and 40-inch spacing. <br /> BL Response: Refer to structural detail 2/S3.01 for all scrubber dump CMU reinforcing. <br /> Section 3/A4.02 annotations have been revised to reference structural drawings. Vertical <br /> reinforcing has been clarified on drawing S1.00. <br /> b. The section should also specify hooks into the foundation as shown in Detail 2/S3.01. <br /> BL Response: Refer to structural detail 2/S3.01 for all scrubber dump slab reinforcing. <br /> Section 3/A4.02 annotations have been revised to reference structural drawings. <br /> c. The type and size of the horizontal joint reinforcement shall be specified. <br /> BL Response: Refer to structural detail 2/S3.01 for all scrubber dump CMU reinforcing. <br /> Section 3/A4.02 annotations have been revised to reference structural drawings. <br /> d. Section 3/A4.02 is not consistent with Detail 2/S3.01, showing a 1-foot extension of the <br /> slab-on-grade versus no slab extension. The drawings shall be coordinated for <br /> consistency. <br /> BL Response: Scrubber dump sections on A4.02 have been revised to conform to the <br /> structural detail 2/S3.01. <br /> Structural <br /> 1. Structural special inspections are required for this project. A statement on special <br /> inspections has not been provided and shall be submitted with the permit documents. The <br />