My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 RIVERSIDE RD AMAZON 2021-04-01
>
Address Records
>
RIVERSIDE RD
>
607
>
AMAZON
>
607 RIVERSIDE RD AMAZON 2021-04-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2021 12:14:05 PM
Creation date
4/1/2021 12:09:13 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
607
Tenant Name
AMAZON
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12/12/2019 City of Everett age 3 <br /> 10:33:33AtM �cJ, <br /> INSPECTION ACTIVITY REPORT <br /> 8/22/2019 8/22/2019 ELEC 09-FINAL SKB CORRECTION (8/22/2019 11:36 AM SKB) <br /> Robot Charging stations cannot have an <br /> energized mail connection sticking out. <br /> (8/22/2019 12:03 PM SKB) <br /> Robot Charging stations cannot have an <br /> energized mail connection sticking out. <br /> 8/22/2019 8/22/2019 ELEC 09-FINAL SKB OTHER Duplicate insp. <br /> 8/22/2019 8/22/2019 ELEC 09-FINAL SKB PARTIAL APPR (8/22/2019 11:36 AM SKB) <br /> Panel MDP1. <br /> (8/22/2019 12:03 PM SKB) <br /> Panel MDP1. <br /> 8/22/2019 8/22/2019 ELEC 09-FINAL SKB PARTIAL APPR eTRAKiT Inspection 8/21/2019 2:34 PM <br /> Request <br /> Contact Name:Alex R <br /> Site Address:607 RIVERSIDE RD <br /> Phone:2535619234 <br /> e-Mail:tarask@olsenelectric.net <br /> (8/22/2019 11:35 AM SKB) <br /> NE and Mid East Break room area <br /> excluding water heater closet and loading <br /> dock areas. <br /> (8/22/2019 11:35 AM SKB) <br /> NE and Mid East Break room area <br /> excluding water heater closet and loading <br /> dock areas. <br /> (8/22/2019 12:03 PM SKB) <br /> NE and Mid East Break room area <br /> excluding water heater closet and loading <br /> dock areas. <br /> 8/26/2019 8/26/2019 ELEC 09-FINAL SKB CORRECTION (8/26/2019 11:21 AM SKB) <br /> Provide physical protection for all <br /> disconnects and electrical cord equipment <br /> at the forklift charging stations in the 200 <br /> amp disconnect at shipping dock loading <br /> zone entrance.Outstanding corrections still <br /> in place on robot charging stations and <br /> server system.Temporary generator asked <br /> to have a ground and neutral the contractors <br /> are too small for the lugs on the ground a <br /> generator provided evidence that the <br /> cabling is 600 V rated and provide physical <br /> protection for conductors and cables laying <br /> on the ground.Electrode has to be <br /> permanently spliced.Blind power to <br /> conveyor systems not yet evaluated.Septic <br /> pump controller not approved seal offs are <br /> supposed be first device at the ground. <br /> 8/26/2019 8/26/2019 ELEC 09-FINAL SKB PARTIAL APPR eTRAKiT Inspection 8/23/2019 8:22 AM <br /> Request <br /> Contact Name:Alex R <br /> Site Address:607 RIVERSIDE RD <br /> Phone:2535619234 <br /> e-Mail:tarask@olsenelectric.net <br /> (8/26/2019 11:21 AM SKB) <br /> Garbage auger and garbage compactor <br /> water tanks loading dock areas excluding <br /> dock levelers beyond the controllers. <br /> INSP12 aillifs ¢. 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.