I <br /> CITY OF EVERETT SPECIAL PROVISIONS <br /> Delete the third and fourth sentences of the fourth paragraph. <br /> 7-08.3(4) Plugging Existing Pipe <br /> Delete the first paragraph of 7-08.3(4) and substitute the following: <br /> Where shown on the plans to plug and seal existing water main, sanitary sewer and storm <br /> drainage pipe plug existing pipe a minimum distance of 2-feet from the inlet end with cement <br /> grout and abandon in place. <br /> 7-08.4 Measurement <br /> Delete all paragraphs in 7-08.4 and substitute the following: <br /> Bid items of Work completed pursuant to the Contract Documents will be measured as described <br /> in Division B — Bid Item Descriptions of these Special Provisions and Section 1-09 <br /> MEASUREMENT AND PAYMENT of the Standard Specifications. <br /> 7-08.5 Payment <br /> Delete all paragraphs in 7-08.5 and substitute the following: <br /> Payment for bid items of Work completed pursuant to the Contract Documents will be as <br /> described in Division B — Bid Item Descriptions of these Special Provisions and Section 1-09 <br /> MEASUREMENT AND PAYMENT of the Standard Specifications. <br /> 7-17 SANITARY SEWERS ' <br /> 7-17.1 Description <br /> Revise the first paragraph in 7-17.1 to read as follows: <br /> This Work consists of constructing gravity sanitary or combined sewer mains using conventional <br /> open trench construction methods, as staked, in accordance with the Plans, these Specifications, <br /> and the COE Standard Drawings. <br /> 7-17.1 Description <br /> Supplement 7-12.1 as follows: <br /> 7-17.1(1) Submittals <br /> (******) <br /> Provide Type 2 Working Drawings for all materials and Standard Plans. <br /> Provide Type 3E Working Drawings for construction of temporary by-passes. <br /> 7-17.2 Materials <br /> Delete list of pipe materials in the first paragraph in 7-17.2 and substitute the following: <br /> Use the following pipe materials for gravity sanitary and combined sewers: I <br /> Rigid Thermoplastic <br /> ABS Composite <br /> Ductile Iron PVC (Polyvinyl Chloride) <br /> Polypropylene <br /> Delete the list of material requirements in 7-17.2 and substitute the following: <br /> Provide materials meeting the following requirements. <br /> Solid Wall PVC Sanitary Sewer Pipe 9-05.12(1) Special Provisions <br /> Profile Wall PVC Sanitary Sewer Pipe 9-05.12(2) Special Provisions <br /> Ductile Iron Sewer Pipe 9-05.13 Special Provisions <br /> ABS Composite Sewer Pipe 9-05.14 Special Provisions <br /> Polypropylene Dual and Triple Wall 9-05.21 Special Provisions <br /> Sanitary Sewer Pipe ' <br /> SEI to SRI Intertie, SRO8 Rehab Division 7—STORM,SEWER WO No.—UP3714 <br /> SP-146 <br /> 1 <br />