My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 2ND FLOOR 2022-01-26
>
Address Records
>
COLBY AVE
>
1321
>
2ND FLOOR
>
1321 COLBY AVE 2ND FLOOR 2022-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 3:26:34 PM
Creation date
5/3/2021 8:56:52 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
131
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROVIDENCE REGIONAL MEDICAL CENTER EVERETT <br />4A BEHAVIORAL HEALTH UNIT <br />Everett, Washington <br />08 71 00 <br />DOOR HARDWARE <br />-chitecture II1-19089 <br />A. Doors 1-3/4" thick minimum use 4-1/2" hinges. <br />B. Each door shall have three (3) hinges. Doors 7'-6" in height and over shall have an <br />additional hinge for each 30" of additional height, or fraction thereof. <br />Page <br />C. Exterior doors over 3'-2" wide and/or 7'-6" high shall have heavy weight hinges. Hinges <br />shall be non-ferrous, non -removable stainless steel pins. <br />D. Hinges shall be sized in width to clear all trim. <br />2.5 LOCKSETS: <br />A. Locks and trim shall be the product of one manufacturer. <br />B. Functions are shown in hardware sets. <br />C. Provide 3/4" minimum latch throw for mortise locks, 1/2" throw for cylindrical locks, and <br />1" throw for deadbolts. <br />2.6 DOOR TOP ALARM SYSTEM <br />A. BEST SEDA System is to be supplied with door top sensor, power supplies, strobe alarms <br />and desk mounted console SEDA-DCR-36. <br />2.6 DOOR CLOSERS: <br />A. Door closers shall be fully adjustable type with complete spring power adjustment, sizes 2 - <br />6 and field adjustable according to door size and frequency of use. Closer shall have <br />adjustable back -check. <br />B. Where closers are indicated to be delayed action, provide units with adjustable delay. <br />C. Where doors are indicated to be accessible to the physically handicapped, provide units that <br />comply with ANSI Al 17.1 provisions for door opening force and delayed action for closing. <br />D. Provide all accessories for mounting required by door and frame types. <br />2.7 EXIT DEVICES: <br />A. Except on fire rated doors, equip exit devices with a dogging feature to hold the push bar <br />down and the latch bolt in the retracted position. <br />B. Where exit devices are required on fire rated doors, provide devices with UL label <br />indicating "Fire Exit Hardware". For doors without fire rating, provide devices listed for <br />"Panic Hardware". <br />2.8 DOOR TRIM UNITS: <br />A. Fabricate protection plates not more than 2" less than door width on stop side of door and <br />not less than I" less than door width on pull side of door. <br />B. Metal plates shall be of stainless steel and .050 or 18 ga. <br />
The URL can be used to link to this page
Your browser does not support the video tag.