Laserfiche WebLink
I <br />i <br />EVERETT <br />October 6, 2020 <br />WAS H I N GTO N <br />Christopher Villa <br />cvilla@alliveproperties.com <br />9 <br />Owner: Christopher Villa <br />Job Address: 7011 McDougall Ave <br />s Plan Check No: B2006-028 <br />I <br />RE: Building Permit Review Letter <br />Dear Mr. Villa, <br />In response to the application for a building permit, the plans have been <br />examined and you are advised that revisions may be necessary before a permit <br />can be issued. Please review and respond to the comments below. <br />6. This comment has not been adequately addressed. The permit <br />response discusses that repairs took place and some of these are cosmetic. It is <br />still unclear in the response if a new shearwall is to be installed as the revised <br />plans do not make references to the previously submitted permit calculations <br />or details. If so, please add construction details and references to the shearwall <br />construction. Also, please note that redesign of a front entryway needs to <br />indicate what was changed from the existing condition to the proposed <br />condition. Currently, the resubmitted elevations do not indicate what is to be <br />installed as part of the redesign. Please clarify. IRC R106.1.1. <br />8. This comment has not been adequately addressed. The permit <br />response indicates that framing and insulation was added along the inside of <br />the existing concrete basement walls, but has not been shown on the <br />resubmitted plans that it is to be installed. Please indicate via section cuts and <br />3 details where it is to occur and that the construction demonstrates code <br />compliance. New work on the plans is to be documented with clarity and that <br />inspectors are able to inspect this work prior to covering the work with finish <br />work. IRC R106.1.1, WSEC R503.1.1. <br />12. This comment has not been adequately addressed. Permit responses <br />indicate a plan to add guardrails, but has not been shown on the plans. Please <br />PERMIT SERVICES <br />show the proposed construction on the plans and details such that it can clearly <br />be constructed and inspected by the contractor and building inspector, <br />3200 Cedar Street <br />respectively. IRC R106.1.1. <br />Everett, WA 98201 <br />14. This comment has not been adequately addressed. Please refer to <br />425.257.8810 <br />425.257.8857 fax <br />Permit Comment 8 of this letter and provide section cuts and details of the final <br />s <br />condition indicating where insulation and subsequent framing is proposed to be <br />everetteps@everettwa.gov <br />installed at this level. Pre -con meetings cannot substitute for providing <br />everettwa.gov/permits <br />construction documents demonstrating code compliance on proposed <br />construction. IRC R106.1.1, WSEC R503.1.1. <br />1 <br />Page 1 of 3 <br />i <br />