3610 GRAND AVE 2021-05-04
>
Address Records
>
GRAND AVE
>
3610
>
3610 GRAND AVE 2021-05-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2021 11:33:43 AM
Creation date
5/4/2021 11:33:27 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
3610
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( g 2 <br /> 4/7/2021 City of Everett <br /> 9:52:58AM <br /> INSPECTION ACTIVITY REPORT <br /> 3/9/2021 3/9/2021 ELEC 09-FINAL SKB CORRECTION eTRAKiT Inspection 3/8/2021 6:16 PM POWERHOUSE <br /> Request ELECTRICAL INC <br /> Contact Name:POWERHOUSE <br /> ELECTRICAL 1NC <br /> Site Address:3610 RUCKER AVE <br /> Phone:2069150492 <br /> e-Mail:powerhousewiring@gmail.com <br /> (3/9/2021 10:50 AM SKB) <br /> AFCl/GFCI protection must be done at the <br /> overcurrent device as this is a stack unit <br /> and the entire circuit must be protected by <br /> AFCI.Show a load calculation for the sub <br /> panel.Derate the conductors in the conduit <br /> feeding the sub panel and install oversized <br /> conductors as needed. <br /> 3/11/2021 3/11/2021 ELEC 09-FINAL SKB CORRECTION eTRAKiT Inspection 3/10/2021 5:14 PM POWERHOUSE <br /> Request ELECTRICAL INC <br /> Contact Name:POWERHOUSE <br /> ELECTRICAL INC <br /> Site Address:3610 RUCKER AVE <br /> Phone:2069150492 <br /> e-Mail:powerhousewiring@gmail.com <br /> (3/11/2021 2:01 PM SKB) <br /> Eaton Breaker is not allowed in the Square <br /> D home line panel.Properly be ready to <br /> wire or install second conduit that goes to <br /> the sub panel.The subpanel needs to have a <br /> load calculation or an over current device <br /> sufficient to carry the entire load.No <br /> diversity is given as this is not carrying the <br /> entire dwelling.Properly install the 3/4"pvc <br /> on the side of the house. <br /> 3/12/2021 3/12/2021 ELEC 09-FINAL SKB APPRVD-PERN eTRAKiT Inspection 3/11/2021 6:26 PM POWERHOUSE <br /> Request ELECTRICAL INC <br /> Available alter 10:00 am <br /> Contact Name:POWERHOUSE <br /> ELECTRICAL INC <br /> Site Address:3610 RUCKER AVE <br /> Phone:2069150492 <br /> e-Mail:powerhousewiring@gmail.com <br /> INSP12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.