Laserfiche WebLink
925 Fourth Avenue <br />Suite 2400 Memo <br />Seattle, WA 98104 <br />r 206 623 9414 <br />7668 Date March 21 2019 <br />ZGFF 206 623 7868 � <br />Project No. S24009 <br />ZIMMER GUNSUL FRASCA ARCHITECTS LLP Project Name PRMCE — D Wing Level 9 <br />Inpatient Unit Buildout <br />Page No. 1 of 6 <br />To Tony Lee, City of Everett <br />From Melinda Wind, Jim Harman <br />Subject Building Permit Review Comments —Plan Check No: B1903-002 <br />This memo provides the responses to the Permit Review comments issued in a letter to Holly Shoubridge at Mortenson <br />Construction dated March 6, 2019 from the City of Everett for the Providence Everett Medical Center, D Wing, Level 9, <br />Impatient Unit Buildout. <br />Construction <br />1. UL listing U428 requires proprietary GWB. As generic Type X is not in the listing, the types of approved GWB (mostly <br />Type C) should be shown on the plans for wall types S, T & W/A8.01. <br />a. Note 6 on Sheet A8.01 indicates the requirement of referring to the UL listing for GWB type, however the three <br />partition types above could cause confusion in the field for the building inspectors. <br />Response: Revised gyp board at partitions S, T, and W to be Type `C' to remove proprietary requirement. See sheet A8.01 for <br />revisions. <br />2. It is not clear how wall type HcA/A8.01 will provide two-hour fire -resistance as the 2nd layer of GWB needed for 2-hour <br />fire -resistance stops above the ceiling. <br />Response: Revised note for HcA wall type to be 1-HR rated, see sheet A8.01. All locations of this wall type within the project <br />occur at 1-HR rated walls. There are no 2-HR rated walls for this type. <br />3. The following comments apply to the horizontal shaft assemblies 17 & 21 /A8.01 Listing AER-09038): <br />a. The listing requires Type C GWB vs. the Type X GWB shown on the details. <br />b. Please verify that the studs chosen do not exceed Span Table 1 provided in the listing. <br />Response: Revised details 17 and 21 on A8.01 to indicate Type `C' gyp board. Revised note to reflect limits of Span Table 1 to <br />be met in performance design of studs. <br />4. Shaft detail 16/A8.01 appears to use both UL 469 for the vertical portions and AER-09038 for the horizontal portions of <br />the assembly. Please verify as UL 469.allows Type X GWB for walls however AER-09038 requires Type C for horizontal <br />applications. <br />Response: Revised detail 16/A8.01 to show Type `C' gyp board, please see revised sheet. <br />5. Listings and references should be provided for the partition STC's shown on Sheet A8.01 where required by Section <br />1207.2 <br />Response: References have been added for STC designated walls, please see revised sheet A8.01. <br />6. Walls separating the sleeping rooms from each other and sleeping rooms from the corridor/other rooms (FbA, NbA, NA, <br />etc.) shown with assemblies that have less than 50 STC on Sheet A8.01. Section 1207.2 <br />AD <br />