My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 13TH ST 9TH FLOOR 2022-01-20
>
Address Records
>
13TH ST
>
1700
>
9TH FLOOR
>
1700 13TH ST 9TH FLOOR 2022-01-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2022 3:05:06 PM
Creation date
5/4/2021 2:09:34 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1700
Tenant Name
9TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. The flushing mechanisms are shown on the near side of the toilet stalls on the typical <br />mounting location drawings of Sheet A7.01. ANSI Section 604.6 <br />2. The drains and hot water supply on the lav's should be shown protected or insulated to <br />prevent contact. ANSI Section 606.6 <br />3. The shower seat should be shown to be within 3" of the compartment entry (vs. the <br />shower entry) in detail 12/A6.01. ANSI Section 610.3 <br />4. Please clarify the intent of the 50" height of the vision lights in cross corridor doors C6 <br />shown on Sheet A8.42 vs. the 43" (or less) heights shown on the other doors on the sheet <br />per ANSI Section 404.2.10 <br />In order for the processing of your application to continue, it will be necessary to provide the <br />Building Division with two new sets of revised construction documents reflecting the corrections <br />requested. Please include a response letter which indicates how the corrections were resolved. <br />All codes cited refer to the 2015 International Building Code (IBC), 2015 International Existing <br />Building Code (IEBC), the 2015 International Fire Code (IFC), the 2015 International Mechanical <br />Code (IMC), and/or the 2015 Washington State Energy Code (WSEC), as amended by the State <br />of Washington and adopted by the City of Everett. The current IBC referenced standard for <br />accessible design is the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI <br />A117.1). Federal ADA regulations and standards may be more restrictive. <br />These comments address building issues only. Additional revisions or additions may be required <br />by other departments (such as Utilities, Traffic, Planning or Fire). All required submittals must <br />be of sufficient detail and information to ensure that the proposed structure will be constructed <br />in compliance with all adopted codes. <br />Sincerely, <br />--------------- <br />T Lee <br />Building Official <br />Q 3200 Cedar Street © 425.257.8810 © tlee@everettwa.gov <br />Everett, WA 98201 425.257.8857 fax everettwa.gov +� <br />
The URL can be used to link to this page
Your browser does not support the video tag.