Laserfiche WebLink
1" E MEMBER REPORT Upper Floor Framing, U-07 Door header PASSED <br /> T 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 <br /> Overall Length:3'2" <br /> + + <br /> o - .:. .�:, _, o <br /> 3'2' 9 <br /> CI L1 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual 6 Location Allowed Result . LOF Load:Combination(Pattern) System:Wall <br /> Member Reaction(Ibs) 3115 @ 0 3281(1.50") Passed(95%) -- 1.0 D+1.0 S(All Spans) I Member Type:Header <br /> Shear(Ibs) 2476 @ 8 3/4" 3502 Passed(71%) 1.15 1.0 D+1.0 S(All Spans) Building Use:Residential <br /> Moment(Ft-Ibs) 2677 @ 1' 3438 Passed(78%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC 2015 <br /> Live Load Defl.(in) 0.013 @ 1'6 3/16" 0.106 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) Design Methodology:ASD <br /> Total Load Defl.(in) 0.021 @ 1'6 3/16" 0.158 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(L/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 3'2"o/c unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 3'2"o/c unless detailed otherwise. <br /> •Applicable calculations are based on NDS. <br /> Bearing Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Snow Total Accessories <br /> Live <br /> 1-Trimmer-HF 1.50" 1.50" 1.50" 1169 63 1946 3178 None <br /> 2-Trimmer-HF 1.50" 1.50" 1.50" 540 63 779 1382 None <br /> fTributary Dead Floor Live Snow <br /> Loads Location(Side) Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 3'2" N/A 6.4 <br /> 1-Uniform(PSF) 0 to 3'2" 1' 10.0 40.0 - Residential-Living <br /> Areas <br /> 2-Uniform(PSF) 0 to 1' 20'9" 11.2 - 25.0 Snow <br /> 3-Uniform(PLF) 1'to 3'2" N/A 60.0 - - Wall <br /> 1 4-Uniform(PLF) 0 to 1' N/A 110.0 - - Wall <br /> Linked from:R-02 <br /> 5-Point(lb) 1' N/A 1185 - 2206 Window Header, <br /> Support 2 <br /> Member Notes <br /> Nook door header /� <br /> Weyerhaeuser Notes , O SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> I(www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need fora design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.cam/services/s_CodeReports.aspx. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Forte Software Operator Job Notes 1'6/2017 10:24:05 AM <br /> =:,oll Duplex 1470 Forte v5.2.Design Engine:V6.6.0.14 <br /> Duplex 1470.4te <br /> Page.' 35 <br />