Laserfiche WebLink
' 0 RIE MEMBER REPORT Upper Floor Framing. U-08 Window header PASSED <br /> 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 <br /> Overall Length:4'3" <br /> 0 0 <br /> 4,3„ <br /> X <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual tql Location Allowed Result LDF Load:Combination(Pattern) System:Wall <br /> Member Reaction(Ibs) 4206 @ 4'1 1/2" 6563(3.00") Passed(64%) -- 1.0 D+1.0 S(All Spans) Member Type:Header <br /> Shear(Ibs) 2797 @ 3'4 3/4" 3502 Passed(80%) _1.15 1.0 D+1.0 S(All Spans) Building Use:Residential <br /> Moment(Ft-Ibs) 2372 @ 3'6" 3438 Passed(69%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC 2015 <br /> Live Load Deft(in) 0.017 @ 2'4 3/16" 0.138 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) Design Methodology:ASD <br /> Total Load Defl.(in) 0.030 @ 2'3 7/8" 0.206 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(L/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 4'3"o/c unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 4'3"o/c unless detailed otherwise. <br /> • Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Snow Total Accessories <br /> Live <br /> 1-Trimmer-HF 1.50" 1.50" 1.50" 400 103 411 914 None <br /> 2-Trimmer-HF 3.00" 3.00" 1.92" 1675 205 2531 4411 None <br /> Tributary Dead Floor Live Snow <br /> Loads • Location(Side) Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 4'3" N/A 6.4 <br /> 1-Uniform(PSF) 0 to 4'3" 1' 10.0 40.0 - Residential-Living <br /> Areas <br /> 2-Uniform(PLF) 0 to 4'3" N/A 60.0 - - Wall <br /> 3-Uniform(PSF) 3'6"to 4'3" 20'9" 11.2 - 25.0 Snow <br /> 4-Uniform(PLF) 3'6"to 4'3" N/A 110.0 - - Wall <br /> Linked from:R-04 <br /> 5-Point(lb) 3'6" N/A 1494 138 2553 Window header, <br /> Support 2 <br /> Member Notes 1 <br /> Kitchen window header /� <br /> Weyerhaeuser Notes @ SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> i Forte Software Operator Job Notes <br /> 3110/2017 3:00:04 PM <br /> cel P:r ell Duplex talc Forte v5.2.Design Engine:V6.6.0.14 <br /> 0,si ,,t.in.^s I Duplex 1470.4te <br /> 31 <br /> .:.. . ,,,1: ,.. .. r Page 1 of 1 <br />