Laserfiche WebLink
FORTE MEMBER REPORT Upper Floor Framing, U-11 Door header PASSED <br /> 2 piece(s) 2 x 6 Hem-Fir No. 2 <br /> Overall Length:3'6" <br /> r� <br /> o -- o <br /> ' 3 6' X <br /> EI 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).AII dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual 0 Location Allowed Result LDF Load:Combination(Pattern) System:Wall <br /> Member Reaction(Ibs) 629 @ 0 1823(1.50") Passed(34%) -- 1.0 D+1.0 S(All Spans) Member Type:Header <br /> Shear(Ibs) 473 @ 7" 1898 Passed(25%) 1.15 1.0 D+1.0 S(All Spans) Building use:Residential <br /> Moment(Ft-Ibs) 600 @ 1'4" 1602 Passed(37%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC 2015 <br /> Live Load Defl.(in) 0.011 @ 1'8 3/8" 0.117 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) Design Methodology:ASD <br /> Total Load Deft.(in) 0.021 @ 1'8 7/16" 0.175 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(1./240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 3'6"o/c unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 3'6"o/c unless detailed otherwise. <br /> •Applicable calculations are based on NDS. <br /> Bearing .._Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Snow Total Accessories <br /> Live <br /> 1-Trimmer-HF 1.50" 1.50" 1.50" 318 70 310 698 None <br /> 2-Trimmer-HF 1.50" 1.50" 1.50" 186 70 177 433 None <br /> Tributary Dead Floor Live Snow <br /> Loads Location(Side) Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 3'6" N/A 4.2 <br /> 1-Uniform(PSF) 0 to 3'6" 1' 10.0 40.0 Residential-Living <br /> Areas <br /> 2-Uniform(PSF) 0 to 1'4" 3' 11.2 - 25.0 Snow <br /> 3-Uniform(PLF) 0 to 1'4" N/A 110.0 - - Wall <br /> 4-Uniform(PLF) 1'4"to 3'6" N/A 30.0 - - Wall <br /> 5-Uniform(PSF) 0 to 3'6" 1' 10.0 - 25.0 Snow(front porch <br /> roof) <br /> Linked from:R-01 <br /> 6-Point(lb) 1'4" N/A 163 - 300 Window Header, <br /> Support 1 <br /> Member Notes 1 <br /> Entry door header <br /> Weyerhaeuser Notes @SUSTAINABLE FORESTRY INrrLATNE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Forte Software Operator Job Notes 1/6/2017 10:24:05 AM <br /> F «r Duplex 1470 Forte v5.2.Design Engine:V6.6.0.14 <br /> Duplex 1470.4te <br /> Pagee 2 ,3b—: <br />