Laserfiche WebLink
rodl1 F A R T E MEMBER REPORT Upper Floor Framing, U-10 Window header PASSED <br /> 1 (� V ! 2 piece(s) 2 x 6 Hem-Fir No. 2 <br /> Overall Length:4'3" <br /> • <br /> 4'3" <br /> 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual <br /> Design Results Actual 0 Location Allowed Result LDF Loath Combination(Pattern) System:Wall <br /> Member Reaction(lbs) 1081 @ 0 1823(1.50") Passed(59%) — 1.0 D+0.75 L+0.75 S(All Spans) Member Type:Header <br /> I Shear(lbs) 718 @ 7" 1650 Passed(44%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential <br /> Moment(Ft-lbs) 985 @ 1'11 3/4" 1393 Passed(71%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2015 <br /> Live Load Defl.(in) 0.035 @ 2'1 1/8" 0.142 Passed(L/999+) -- 1.0 D+0.75 L+0.75 S(All Spans) Design Methodology:ASD <br /> Total Load Defl.(in) 0.061 @ 2'1 1/16" 0.213 Passed(L/834) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(L/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 4'3"o/c unless detailed otherwise. <br /> •Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 4'3"o/c unless detailed otherwise. <br /> •Applicable calculations are based on NDS. <br /> Bearing Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Snow Total Accessories <br /> Live <br /> 1-Trimmer-HF 1.50" 1.50" 1.50" 470 524 290 1284 None <br /> 2-Trimmer-HF 1.50" 1.50" 1.50" 344 524 99 967 None <br /> Tributary Dead Floor Live Snow <br /> Loads Location(Side) Width (0,90) (1.00) (1.15) Comments <br /> 0-Self Weigh:(PLF) 0 to 4'3' N/A 4.2 <br /> Residential-Living <br /> 1-Uniform(PSF) 0 to 4'3" 6'2" 10.0 40.0 Areas <br /> 2-Uniform(PLF) 0 to 1'4" N/A 110.0 - - Wall <br /> 3-Uniform(PSF) 0 to 1'4" 4'6" 11.2 - 25.0 Snow <br /> 4-Uniform(PLF) 1'4"to 4'3" N/A 70.0 - - Wall <br /> Linked from:R-07 <br /> 5-Point(lb) 1'4" N/A 116 - 239 Window header, <br /> Support 2 <br /> Member Notes <br /> Living room window <br /> ;:.Weyerhaeuser Notes • t} SUSTAINABLE FORESTRY INITIATIVE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. <br /> Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Forte Software Operator Job Notes 1/6/2017 10:24:05 AM <br /> Duplex 147 Forte v5.2.Design Engine:V6.6.0.14 <br /> Duplex 1470.4te <br /> • <br /> _.. _. Page 1 of 35 <br />