My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1913 HOYT AVE C D 2022-05-23
>
Address Records
>
HOYT AVE
>
1913
>
1913 HOYT AVE C D 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:58:47 AM
Creation date
5/4/2021 2:49:50 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
1913
Unit
C D
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLIC WORKS <br /> November 21, 2017 <br /> Andrew Echelbarger <br /> Hoyt Avenue Residences, LLC <br /> 18833 10th Drive SE <br /> Bothell, WA 98012 <br /> echelbargera@gmail.com <br /> Owner: Hoyt Avenue Residences LLC <br /> Job Address: 1913 Hoyt Ave C & D <br /> Plan Check No: B1711-024 <br /> RE: Building Permit Review Letter <br /> Dear Mr. Echelbarger, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> General <br /> 1. The cover sheet should show the occupancy types (R-3 & U), type of construction, floor <br /> area and pertinent construction codes. Section 107.2.1 <br /> 2. The type of sprinkler system to be installed in the building should be noted on the plans <br /> — they currently show an option between NFPA or NFPA 13-R. The different sprinkler <br /> types produce different outcomes in the plan review. Section 903.2.8 <br /> 3. An NFPA-72 fire alarm is required for this structure as it is over 3000 square feet in area. <br /> City of Everett Chapter 16.76 <br /> 4. The general notes that refer to the IRC should be revised to the IBC. Section 107.2.1 <br /> 5. The exterior walls (each story) facing the N & S property lines should be shown as <br /> minimum one-hour, fire-resistive construction (symmetrical) — the wall and building <br /> sections should reference the (un-marked) 1-hour exterior wall detail provided on Sheet <br /> 7. Sections 602 &705.5 <br /> 6. The outboard steel columns should be shown with minimum one-hour fire-resistive <br /> protection. A listing and detail should be provided. Section 705.5 <br /> 7. The steel beams and inboard steel column should be covered by minimum 1/2" GWB. A <br /> detail should be provided. Section 406.3.4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.