My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1622 E MARINE VIEW DR WHOLE SITE 2022-02-01
>
Address Records
>
E MARINE VIEW DR
>
1622
>
WHOLE SITE
>
1622 E MARINE VIEW DR WHOLE SITE 2022-02-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2022 2:59:04 PM
Creation date
5/5/2021 11:01:10 AM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
1622
Tenant Name
WHOLE SITE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
932
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Riverview Apartments December 12 2018 <br />Response to Design Review Comments, Public Works Page 2 of 3 <br />CPH No. 0024-17-037 <br />vii. Sheet C5.01. <br />Response: <br />• The 90° bend in the water main at the intersection of Drives B and C has been updated to <br />two 450 bends. <br />• Two gate valves have been added on either side of the fire hydrant connection near the <br />west end of Drive C. <br />• All construction notes referencing a I" fire service have been updated to reference a 2" <br />fire service. <br />• The thrust block will remain for the fire hydrant connection at STA 31 +95.20 along Drive <br />C in order to use an MJ tee. <br />• The water main near the intersection of Drives C and E has been adjusted in order to keep <br />the fire service lines for buildings C and D under the 70 foot maximum length. <br />• A note has been added to state that connection to the existing water main shall be <br />performed by City crews. <br />• A note has been added to state that COE utility crews shall have access to the mechanical <br />rooms from 7:30am to 4:OOpm, Monday through Friday. <br />viii. Sheet C5.02. <br />Response: <br />• All construction notes referencing a I" fire service have been updated to reference a 2" <br />fire service. <br />• The fire service for building H has been shifted to the east and a vault will be added in the <br />planter. <br />• A note has been added to state that connection to the existing water main shall be <br />performed by City crews. <br />• A note has been added stating the contractor shall pothole along Chestnut Street to verify <br />location of 8" water main. <br />ix. Sheet C7.00. <br />Response: Additional AutoTurn routes have been added to sheet C7.00. <br />2. Planning Department <br />3. Stormwater Reviewer <br />a. Sanitary Sewer <br />Minimum slope for sanitary sewer main is 0.75%, revise sewer main design so minimum <br />slope of new sewer main is 0.75%. <br />Response: Sanitary sewer main has been updated to a minimum slope of 0.75%. <br />b. Surface Water <br />Detention pipe - corrugated steel detention pipe is not allowed. See Drawing 418 of the <br />COE Design and Construction Standards and Specifications (DCSS) for acceptable pipe <br />materials. <br />Response: All references to CMP have been removed from the civil plans. A note has been <br />added to reference COE Std. Dwg. 418. <br />Minimum connecting pipe diameter is 48-inches between detention pipes. Connecting pipe <br />IE's shall be level with vault. <br />
The URL can be used to link to this page
Your browser does not support the video tag.