My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1622 E MARINE VIEW DR BUILDING B 2022-08-29
>
Address Records
>
E MARINE VIEW DR
>
1622
>
BUILDING B
>
1622 E MARINE VIEW DR BUILDING B 2022-08-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2022 9:54:22 AM
Creation date
5/5/2021 3:50:08 PM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
1622
Tenant Name
BUILDING B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> OLT CITY OF EVERETT <br /> Public Works Department <br /> March 22, 2019 <br /> Seth Terry <br /> Johnson Braund, Inc. <br /> 15200 52nd Ave. South, Suite 300 <br /> Seattle, WA 98188 <br /> sethtPjohnsonbraund.com <br /> Owner: Riverview I, LLC <br /> Job Address: 1622 East Marine View Drive <br /> Plan Check No: B1812-027, Building B <br /> RE: Building Permit Review Letter <br /> Dear Mr. Terry, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> NON STRUCTURAL <br /> General <br /> 1. Electric vehicle charging locations and infrastructure requirements should be shown on <br /> the plans. Section 427 <br /> 2. The special inspector qualifications, required inspections and reporting requirements of <br /> RCW 64.55 should be shown on the plans. <br /> 3. Smoke detectors should be noted to be interconnected within each unit. Section <br /> 907.2.11.5 <br /> 4. The smoke detector located in the hallway of unit types 1.1, 1.2, 1.3, 3.2 &3.3 should be <br /> shown to be minimum of 3' away from the bathroom doors. Section 907.2.11.4 <br /> 5. The insulation in floor/ceiling assembly 8D is not permitted to exceed 3" in thickness and <br /> must be attached directly to the underside of the sub-floor unless an additional layer of <br /> GWB is added per U.L. <br /> 6. The ceiling vents in details 8 &15/A500 are through one-hour fire-rated horizontal <br /> assemblies and should either be shown with listed membrane fire-stops, sleeved by metal <br /> 0 3200 Cedar Street © 425.257.8810 O tlee@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.