• • <br /> conduit and shown to be less than 100 square inches in 100 square feet or removed. <br /> Section 714.4.2 <br /> 7. The construction of the storerooms that are accessed via the unit decks should be shown <br /> on the plans: <br /> a. Load bearing walls should be minimum one-hour construction. Section 602.1 <br /> b. The floor/ceiling assemblies should minimum one-hour construction. 602.1 <br /> 8. The doors through the attic draftstops should be shown as self-closing with automatic <br /> latches. Section 718.4.2 <br /> 9. The sizing of the local exhaust fans should be shown on the plans. IMC Section 403.8.4 <br /> 10.The whole house fan requirements should be shown on the plans to include size of fan, <br /> sone rating, outdoor air and controls. IMC Section 403.8.5 <br /> Egress <br /> 1. Per Section 1019.3, the exterior exit stairs serving this four-story building should be shown <br /> to comply with Section 713: <br /> a. The walls separating the stairways from the dwelling units should be shown as <br /> minimum two-hour fire barriers. Sections 713.4 & 1027.6 <br /> b. The stairways include landings. On the first floor,the stairways/landings adjoin the <br /> deck storage units on two sides. The two-hour fire separation should be shown <br /> between the landings and storage units and to continue horizontally to the edge <br /> of the roof. Section 1027.6 <br /> c. The first story deck and storage units adjacent to the stair landings are less than <br /> 180 degrees from the stairs/covered landings. Minimum one-hour walls should <br /> extend for a minimum of 10 feet from the landings. Openings within the walls <br /> should be shown with minimum 3/4-hour opening protection. Sections 1027.6 & <br /> 1023.7 <br /> 2. The openings between the stairway treads should be shown to be less than 4". Section <br /> 1011.5.5.3 <br /> 3. The stair handrails that are not continuous between runs should be shown to return to a <br /> wall, guard or the walking surface. Section 1014.6 <br /> Accessibility/ANSI A117.1 <br /> 1. The hallway in Unit 1.3 should be shown to be a minimum of 48"wide clear due to the <br /> bathroom door opening into the hall. ANSI Section 404.2.3 <br /> STRUCTURAL <br /> 1. Under separate review letter. <br /> OO 3200 Cedar Street 0 425.257.8810 tlee@everettwa.gov <br /> Everett,WA 98201 ' 425.257.8857 fax O everettwa.gov <br />