Riverview E I WSEC Air Barrier Testing Report <br /> B G L I V I D A <br /> Table 10: Zone "ends" Depressurized Airflow Data <br /> Target dP (Pa) Corrected dP Measured Airflow(CFM) Leakage (CFM) <br /> -75.0 -74.9 4,942 4,905 <br /> -70.0 -70.3 4,736 4,701 <br /> -65.0 -65.4 4,523 4,489 <br /> -60.0 -60.4 4,278 4,246 <br /> -55.0 -55.3 4,029 3,999 <br /> -50.0 -50.4 3,831 3,802 <br /> -45.0 -45.3 3,571 3,544 <br /> -40.0 -40.0 3,143 3,119 <br /> Figure 1: Zone "ends" Graph of Standard Airflow vs Differential Pressure <br /> 6500 - <br /> Pressurization Trendline <br /> Pressurization Data <br /> 6000 - <br /> --- Depressurization Trendline <br /> E Depressurization Data <br /> 5500 - <br /> 5000 - <br /> g 4500 - • <br /> _•'- <br /> (o <br /> J .' <br /> 4000 - <br /> • <br /> 3500 -,•• <br /> .‘ <br /> 3000 <br /> 35 40 45 50 55 60 65 70 75 80 <br /> Differential Pressure (Pa) <br /> Page 7112 <br />