Laserfiche WebLink
• <br /> <1 1> <br /> JOHNSON BRAUND IN VE <br /> '( MAY 3 1 2019 <br /> May 28,2019 <br /> CITY OF EVERETT <br /> Permit Services <br /> Tony Lee <br /> Building Official <br /> City of Everett—Public Works Department <br /> 3200 Cedar Street <br /> Everett,WA 98201 <br /> RE: SHAFFER ASSEMBLAGE—RIVERVIEW APARTMENTS—BUILDING G <br /> NON-STRUCTURAL REVIEW LETTER#1 <br /> PERMIT#B1812-032 <br /> Mr. Lee, <br /> We are submitting the following response to your Building Permit Review Letter dated March 22, <br /> 2019, together with two complete sets of revised drawings for your review and approval. The <br /> responses below are grouped and numbered per your original letter,which is attached for reference. <br /> General <br /> 1. Code review and notes on A010 have been adjusted to match construction type V-B. See <br /> updated notes on sheet A010. <br /> 2. EV charging stations infrastructure in compliance with Section 427 to be provided. See <br /> notes added to sheet A010. <br /> 3. The special inspector qualifications, required inspections and reporting requirements of <br /> RCW 64.55 are shown on the envelope consultant's XBE series of sheets. <br /> 4. See revised note 7 on apartment unit plan sheets. Smoke detectors within dwelling units to <br /> be on same circuit(living room circuit)and are to be interconnected per 907.2.11.5. <br /> 5. Smoke detector locations have been revised as requested. Smoke detectors to be <br /> photoelectric type and will be located 3' from bathroom door except where this would <br /> prevent a smoke detector to be placed in locations required by 907.2.11.1 or 907.2.11.2 <br /> 6. Graphics for assembly 8D on page A040 have been revised to reflect requirements of UL <br /> assembly. <br /> 7. Sheet A042 has been added to the set to include construction details for assembly types <br /> 8D1 and 9A1. The tags for assembly types 8A1 and 8B1 as shown previously on plans <br /> have been updated to identify the appropriate assembly type described on the A04x sheets. <br /> Energy/Ventilation <br /> 1. Exhaust fans to be under separate permit. <br /> 2. Whole house fan to be under separate permit. <br /> 15200 52nd Avenue South,Suite 300,Seattle,Washington 98188 <br /> Phone 206.766.8300 <br /> www.johnsonbraund.com <br /> ARCHITECTURE INTERIOR DESIGN <br /> (_& <br />