Laserfiche WebLink
IIIIII <br /> zii <br /> PLAN NOTES �` <br /> MEANS OF EGRESS ILLUMINATION(IBC SECTION 1006): 1. SEE SHEET A040,A941 SHEETS `Y' <br /> COMPOSITIONEEASTD7158CHINGLE ROOFING FOR FIRE-RESISTIVE ASSEMBLIES JOHNSON BRAUNDuc. <br /> A TO MEET ASTM CLASS G OR A ILLUMINATION SHALL BE PROVIDED AT EVERY POINT IN THE MEANS OF 15200 52nd Ave.South <br /> H,OR ASTM D3161 CLASS F OVER 2"0 HOLES IN BIRD BLOCKING FOR EGRESS,THE ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT- H--- ASSEMBLY TAG <br /> ONE LAYER OF UNDERLAYMENT, ATTIC VENTING. CANDLE(11 LUX)AT THE WALKING SURFACE AT ALL TIMES THE SPACE Suite 300 <br /> TYP. 3 PER TRUSS BAY W/1/8"MESH SERVED BY THE MEANS OF EGRESS IS OCCUPIED.LUMINARIES SHALL SEE CS SHEETS FOR KEY PLANS Seattle,WA 98188 <br /> eroeen <br /> BE INSTALLED WHENEVER EXIT SIGNS ARE REQUIRED. Phone 206.766.8300 <br /> ROOF DIAPHRAGM 2. SEE ENLARGED UNIT PLAN v0.A0.hnsonbraund.com <br /> 6'PREFINISHED ALUMINUM All! B. POWER SUPPLY TO BE PROVIDED BY PREMISES'ELECTRICAL SUPPLY. ry <br /> K-STYLE GUTTERS,TYP. IN EVENT OF POWER SUPPLY FAILURE,AN EMERGENCY POWER SHEETS FOR INTERIOR <br /> � �r imix•i � DIMENSIONS,WINDOW AND DOOR ARCHITECTURE <br /> • <br /> DS DS "� " SYSTEM SHALL AUTOMATICALLY ILLUMINATE AREAS REQUIRED PER <br /> :u, .... �41) ,I IBC SECTION 1006.3 INCLUDING:CORRIDORS,EXIT ENCLOSURES,EXIT RATED WA,AND LOCATION OF INTERIOR DESIGN <br /> DS \���� ��`�'������� �� �� �������� ������� DS �'�r 'RP . PASSAGEWAYS,INTERIOR EXIT DISCHARGE ELEMENTS AND EXTERIOR Greg L.AIvuon.AIA <br /> \\\\\`"�;�`�``� �N NN N. �`\\' `�`\�"""" - LANDINGS FOR EXIT DISCHARGE DOORWAYS. 3 ELECTRICAL&MECHANICAL:/ ILD Jeffrey A.Williams,AtA <br /> \ TRUSS TOP CHORD RAFTER TAIL C EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A 1TRCFM EXHAUST <br /> \\\ V��\\�\ DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF <br /> I. <br /> I N I TRUSS BEYOND STORAGE BATTERIES,UNIT EQUIPMENT OR AN ON-SITE GENERATOR. FAN IN EACH. <br /> TRUSS REFER TO ELECTRICAL BIDDER/DESIGN PLANS FOR SYSTEM DESIGN. GARAGE <br /> n N I 4. RECESSED/1-HOUR FIRE <br /> BLOCKING PER F E.C. <br /> STRUCTURAL SEE STAR SECTIONS ON SHEET A621 FOR EMERGENCY LIGHT FIXTURE EXTINGUISHER-BEE SHEET _ <br /> ' A030,LOCATE PER IFC LS2J <br /> I LOCATION. TYPE 5L0 AC <br /> „_. ;.. RIDGE VENT WALL TOP SIZE 2A 10BC <br /> PLATE <br /> 1 • REFER TO DESIGN/BUILD <br /> --. -. 5. PLUMBING PLANS. <br /> RIDGE VENT RIDGE VENT REFER TO DESIGN/BUILD <br /> ' ' 6. ELECTRICAL PLANS. <br /> II c 1 n 0cl <br /> I / e \EAVE VFNTING DIAGRAM 7 REFER TOSHEETAD3OFOR oot <br /> b- <br /> 0 <br /> 0 1 12'-1'-O' PENETRATION REQUIREMENTS IN REGISTERED <br /> FIRE RATED CONSTRUCTION. ARCHITECT <br /> �\,\�\\ \\��1p;/12 70/12' \� \&N�\. 10'/12 10./12' \��\ N\� ATTIC VENTILATION CALCULATIONS 8 LEVELS 1-3 CONSTRUCTION TYPE VB, <br /> \�\\\\\\\�\x\`!1` I \`\\\�\ �\`_iwk\\\ ,1 \I`��\\\\\\\\\\\\` ATTIC AREA 1:250,042 S.I(1,736.4 SF) OCCUPANCIES R-2 S-2 \_. <br /> 1\`` \I� 1` 000 1 -- CEILING ASSEMBLY AT BOTTOM CHORD OF ROOF TRUSSES INCLUDES FFREY ARTHUR WILLIAM <br /> DS �\ -`i` 1 DS n ��\� m�` DS CLASS II VAPOR BARRIER.REQUIRED VENTILATION @ 1/300(IBC 9. ALL LEVELS FULLY SPRINKLERED PER STATE Or w HINGTON <br /> SECTION 1203.2 EXCEPTION):833.5 S.I.(5.8 S.F.) <br /> IBC SECTION 903.3.1.1(NFPA 13). <br /> 10. UNIT DEMISING WALLS ARE 1-HOUR <br /> EAVE VENTILATION 166'L.F.(1,176 L.I.) RATED PER IBC SECTION 708 W/ <br /> AI <br /> ICE E D 24 SHIELD,ACTIP. BIRD BLOCKING WITH THREE 2"DIAMETER HOLES PER TRUSS MINIMUM STC 50, <br /> VIP OF <br /> 24"BEYOND FACE BAY W/1/8"MESH SCREEN 2.50 S.I.(.0174 S.F.)NFA PER NOTCH. <br /> OF EXTERIOR WALL SEE SEE DIAGRAM 1/A501 3.75 S.I.(.026 S.F.)NET FREE AREA PER 11. DIMENSIONS ARE TO OUTSIDE EDGE OF <br /> 3BE4.0 LINEAL FOOT=622.5 S.I.(4.32 S.F.)TOTAL CONCRETE OR FACE OF STUD,TYP. <br /> / o \BSI DING H-ROOF CONTINUOUS RIDGE VENTILATION:34 L.F. 12. SEE STRUCTURAL DRAWINGS <br /> COR-A-VENT REVOLUTION @ 12 S.I.NET PER FT.=34 FT'12 FOR ROOF FRAMING. <br /> 1/8"=1'-0" S.I./FT=408 S.I.(3 S.F.)TOTAL <br /> 13. ALL ROOFING TO BE CLASS B <br /> TOTAL PROVIDED VENTILATION:367.5 S.I+504 S.I+318 S.I.+264 S.I.= MINIMUM PER IBC SECTION 1505 <br /> 1,453.5 S.I.(70.09 S.F.) AND TABLE 1505.1. <br /> T • <br /> SAVE&SOFFIT VENTS:(622.5/833.5)'100=74.7% 14. ALL ROOF SLOPES ARE 5/12 U.N.O. p <br /> HIGH VENTS:(408/833.5)'700=48.9% STEP GARAGE FOOTINGS&SLABS <br /> 15. DRAFTATTICS ORO ARE REQUIRED IN <br /> D n <br /> Aiii) O AS REQUIRED FOR GRADE CHANGE O ATTICS OTHER CONCEALED ° <br /> / 72•_1• / m <br /> ROOF SPACES PER IBC SECTION p <br /> 716.az. r 5 <br /> 72'-1" / / / / 16. PER IBC SECTION 708.4,IN COMBUSTIBLE <br /> 3'-1 12" 7 12" CONSTRUCTION WHERE THE FIRE E <br /> 5'-712" 6'-112" 3'-112" 6'-112" 5'- <br /> 11' 6" / / / / / / / / / / / E <br /> PARTITIONSCONTINUOUS <br /> NOTHE SHEET ITON b <br /> V / / 1 BE CONTINUOUS TO THE SHEATHING, <br /> UNE OF AIR BARRIER r __ DECK OR SLAB,THE SPACE E <br /> DS l_ - _ DECK OR SLAB a <br /> BETWEEN THE CEILING AND THE <br /> :may-a.R�a:= -:�: SHEATHING ABOVE <br /> :� H H �'v H H O SHALL BE FIRE BLOCKED OR <br /> • .5 /� DS O DS O 1`� © T O DS 7A O DS <br /> 7O iv Ilk <br /> L- --/ 1 17�\ _ _ _ DRAFTSTOPPED IN ACCORDANCE <br /> r / �'��..C1WITH IBC SECTIONS 718.2 AND o <br /> I� • 718.3 AT THE PARTITION LINE. <br /> ----0 o----' `--� _$___ �}- a 0-----� EXCEPTION WS:ATTIC FIREBLOCKING OR <br /> iiIFAIIMMI <br /> ^ IV 1 _ 7A DRAFTSTOPPING IS NOT REQUIRED AT THE <br /> PARTITION LINE IN GROUP R-2 BUILDINGShI' - pp_�___ 78 THAT DO NOT EXCEED FOUR STORIES ABOV711 <br /> -o a UNIT 5.1 - im UN © o GARAGE 1 GARAGE 2 _ 1 tli GARAGE 5 GARAGE 6 © S 3UBD V TED DRAFTSTOPPING INTOACE ISSUE DATE 07/19/19 <br /> AREAS I E <br /> -{ GARI."- GARAGE4 3,000 SF OR <br /> E <br /> ' 2N ' --_ 12/A150 J --- 1 I' LIT 5. - %IV I -- -- ry-- --- }� _ - - ----' ---- ® EVERY TWO DWELLING UNITS,WHICHEVERB <br /> TI <br /> N I 2/A150 m f b .. FACP\ IS SMALLER. <br /> + 1j 1 .�I 6,��P `I <br /> '� ��- „ -■. �' - -, -PRINKLER 17. 2"GYP,SHEATHING TOR 1/2"ERIALS TO BE <br /> PLYWOOD OR OSB SHEATHING PER <br /> MEN <br /> oS 11 6DS „ 11 6' -(/''�' 0 <br /> 0 <br /> 0 I=' - /''�I IBCSECTIONING S1. <br /> © .�1100 ' _ham � � �/ © -- _- }- O- �J O \l - �/ <br /> - ___ _ ui 79. DRAFTSTOPPING SHALL BE <br /> 'o -- `--'--- - - - -' d 2 u-.J T'a d INSTALLED ABOVE,AND IN UNE WITH <br /> e 4 2 <br /> is -- 41•• 5'-6" 5-6" 5'-6" 5'-6" 5'-fi" <br /> SLEEPING UNIT AND DWE W NG UNIT <br /> I <br /> /S .�' D / ,�' ,�' ,�' 4 DS/ SEPARATION WALLS THAT DO NOT <br /> 6-1" 33-0 EXTEND TO THE UNDERSIDE OF THE <br /> / 1 / / <br /> ROOF SHEATHING ABOVE PER IBC <br /> - 0 a 16'SIMPSON T18"R NGWA N SECTION 718.4.2. <br /> 0 0 STRONGWALL a a STRONGWALL L O EXCEPTION i13:IN OCCUPANCIES IN GROUPVP <br /> PER PER A THAT NOTEXCEED FOUR STORIES MY <br /> STRUCTURALVIV STRUCTURAL ABOVE GRADE PLANE,THE ATTIC SPACE <br /> SHALL BE SUBDIVIDED BY DRAFTSTOPS INTO <br /> AREAS NOT EXCEEDING 3,000 SF OR ABOVE 3 <br /> EVERY TWO DWELLING UNITS,WHICHEVER IS S <br /> C SMALLER. 1 <br /> ��BUILDING H-FLOOR 3 0/2�BUILDING H-FLOOR 1 <br /> V 1/8'=1'-0' \I`n>V 1/8"=1'-0" 20. PER IBC SECTION 1203.2 EXCEPTION: V <br /> THE NET FREE CROSS-VENTILATION AREA <br /> o O OT SHALL BE PERMITTED TO BE REDUCED TO w 3 <br /> 1/300 PROVIDED BOTH OF THE FOLLOWING <br /> CONDITIONS ARE MET: <br /> / / 1.IN CLIMATE ZONES 6,7,AND 8,A CLASS I g <br /> w 72'-I" OR II VAPOR RETARDER IS INSTALLED ON > 6 <br /> c / / I I THE WARM-IN-WINTER SIDE OF THE CEILING. N 6 <br /> O LINE OF AIR BARRIER / 72-1 / 2.AT LEAST 40 PERCENT AND NOT MORE <br /> cap - 33'-6" 5'-1" 33'-6' THAN 50 PERCENT OF THE REQUIRED = w & <br /> IE <br /> / / / / VENTING AREA IS PROVIDED BY j <br /> - 7A�1 VENTILATORS LOCATED IN THE UPPER L' w <br /> ' °r EMERGENC Il GI ESS t ~� o PORTION OF THE ATTIC A RAFTER SPACE. G ? g 0I I <br /> MI 'off __'----.-o-__ �-_ ,.-�.,_ 1 UPPER VENTILATORS SHALL BE LOCATED �Q a <br /> tV /1 DS _ _ - _ _ _ - _ DS __ O _ _ /� NOT MORE THAN 3 FEET BELOW THE RIDGE 3 pg <br /> p ( 1 `"� r--- I I•- C 1 1 \ -__ ___ __ _ ___ __ --( 1 ) OR HIGHEST POINT OF THE SPACE, OS <br /> yk €g <br /> rn II•��•iY - - -- -- - - - �- - ,_ - - - - -- - - - �J MEASURED VERTICALLY,WITH THE BALANCE �w $: <br /> 1 ppp 1 OF THE VENTILATIO NPROVIDED BY SAVE OR <br /> _ 0 } LIGHTING ;!, �p LIGHTING LITHONIA } II I Q n'w N rA <br /> M pp CORNICE VENTS.WHERE THE LOCATION OF R.> P <br /> LITHONIA EL 2 1 VGR1 I _ r!W <br /> E ;I II I WALL OR ROOF FRAMING MEMBERS rn o0 <br /> to UNIT 5.1 1 7C f 1 7C UNIT 5.1 CONFLICTS WITH THE INSTALLATION OF rn z = o ff B <br /> U ( IIi. 1 II UPPER VENTILATORS,INSTALLATION MORE _d w a m§LL 6 0 <br /> 1/A150 I 1/A150 THAN 3 FEET BELOW THE RIDGE OR p a u ; <br /> 1 Inn <br /> © III HIGHEST POINT OF THE SPACE SHALL BE •� Q J gam <br /> 1 3 [fill] <br /> 1 PERMITTED. <br /> ' •�� MY m II \ If d w 3mzv< o <br /> um (0 �[Z] ' O o r 21. BATHROOMS SHALL BE 3 'm N >H= <br /> In yp-- LZ] I "• .yp-- II MECHANICALLY VENTILATED IN 2N <br /> --- --- 'II - - I ACCORDANCE WITH THE IMC PER IBC Lat. u O rc m ag <br /> _ct--- m . v ---- 1 cO b a I SECTION 1203.6.2.1. <br /> ���-os J - Ds. l� i -- L- ( L J' _ ___ LIGHTING LEGEND <br /> E 2 �J _ __�- _-O O.\ --_��---.��--}-Fl _ _-P_�----�_�_-_�_ _ i- 2 PROJECT#. 1705 <br /> V 1 ry DS LITHONIA VGRI,3.7"DEEP PER DRAWN BY: AT <br /> O "'\ hi' 1„ 'I r MANUFACTURER. <br /> CHECKED BY: ST <br /> t I23'-1" 7'-6" 17'-0" / / / / TO BE USED AS EGRESS <br /> • H / / / LIGHTING PER IBC SECTION <br /> w O a O O B PHOTOCELL TO <br /> T ENSURE S BY <br /> LEVELS OUREUGHT BUILDING PLANS- <br /> Li OF 1 <br /> VP ___/ <br /> J FOOTCAND EIN.AT THE WALKING CARRIAGE H <br /> UTHONIA ELM 2-LED,3 5/8" <br /> �� 1 DEEP PER MANUFACTURER. <br /> (r i\ BUD DING H-FLOOR 2 0( '\BUILDING H-FOUNDATION �''- TO BE USED AS EMERGENCY <br /> \I`n>V 7/8'=1'-0" FLIXTURE TOP R PROVBC IDE <br /> MIIPI ON <br /> A217 <br /> 1008.3.BATTERY BACK-UP IN <br /> w FIXTURE PROVIDE MIN.90 <br /> MINUTES OF ILLUMINATION IN <br /> ,� FAILURE,NT OF A POWER BID/CONSTRUCTION <br />