<br /> PLAN NOTES �`
<br /> MEANS OF EGRESS ILLUMINATION(IBC SECTION 1006): 1. SEE SHEET A040,A941 SHEETS `Y'
<br /> COMPOSITIONEEASTD7158CHINGLE ROOFING FOR FIRE-RESISTIVE ASSEMBLIES JOHNSON BRAUNDuc.
<br /> A TO MEET ASTM CLASS G OR A ILLUMINATION SHALL BE PROVIDED AT EVERY POINT IN THE MEANS OF 15200 52nd Ave.South
<br /> H,OR ASTM D3161 CLASS F OVER 2"0 HOLES IN BIRD BLOCKING FOR EGRESS,THE ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT- H--- ASSEMBLY TAG
<br /> ONE LAYER OF UNDERLAYMENT, ATTIC VENTING. CANDLE(11 LUX)AT THE WALKING SURFACE AT ALL TIMES THE SPACE Suite 300
<br /> TYP. 3 PER TRUSS BAY W/1/8"MESH SERVED BY THE MEANS OF EGRESS IS OCCUPIED.LUMINARIES SHALL SEE CS SHEETS FOR KEY PLANS Seattle,WA 98188
<br /> eroeen
<br /> BE INSTALLED WHENEVER EXIT SIGNS ARE REQUIRED. Phone 206.766.8300
<br /> ROOF DIAPHRAGM 2. SEE ENLARGED UNIT PLAN v0.A0.hnsonbraund.com
<br /> 6'PREFINISHED ALUMINUM All! B. POWER SUPPLY TO BE PROVIDED BY PREMISES'ELECTRICAL SUPPLY. ry
<br /> K-STYLE GUTTERS,TYP. IN EVENT OF POWER SUPPLY FAILURE,AN EMERGENCY POWER SHEETS FOR INTERIOR
<br /> � �r imix•i � DIMENSIONS,WINDOW AND DOOR ARCHITECTURE
<br /> •
<br /> DS DS "� " SYSTEM SHALL AUTOMATICALLY ILLUMINATE AREAS REQUIRED PER
<br /> :u, .... �41) ,I IBC SECTION 1006.3 INCLUDING:CORRIDORS,EXIT ENCLOSURES,EXIT RATED WA,AND LOCATION OF INTERIOR DESIGN
<br /> DS \���� ��`�'������� �� �� �������� ������� DS �'�r 'RP . PASSAGEWAYS,INTERIOR EXIT DISCHARGE ELEMENTS AND EXTERIOR Greg L.AIvuon.AIA
<br /> \\\\\`"�;�`�``� �N NN N. �`\\' `�`\�"""" - LANDINGS FOR EXIT DISCHARGE DOORWAYS. 3 ELECTRICAL&MECHANICAL:/ ILD Jeffrey A.Williams,AtA
<br /> \ TRUSS TOP CHORD RAFTER TAIL C EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A 1TRCFM EXHAUST
<br /> \\\ V��\\�\ DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF
<br /> I.
<br /> I N I TRUSS BEYOND STORAGE BATTERIES,UNIT EQUIPMENT OR AN ON-SITE GENERATOR. FAN IN EACH.
<br /> TRUSS REFER TO ELECTRICAL BIDDER/DESIGN PLANS FOR SYSTEM DESIGN. GARAGE
<br /> n N I 4. RECESSED/1-HOUR FIRE
<br /> BLOCKING PER F E.C.
<br /> STRUCTURAL SEE STAR SECTIONS ON SHEET A621 FOR EMERGENCY LIGHT FIXTURE EXTINGUISHER-BEE SHEET _
<br /> ' A030,LOCATE PER IFC LS2J
<br /> I LOCATION. TYPE 5L0 AC
<br /> „_. ;.. RIDGE VENT WALL TOP SIZE 2A 10BC
<br /> PLATE
<br /> 1 • REFER TO DESIGN/BUILD
<br /> --. -. 5. PLUMBING PLANS.
<br /> RIDGE VENT RIDGE VENT REFER TO DESIGN/BUILD
<br /> ' ' 6. ELECTRICAL PLANS.
<br /> II c 1 n 0cl
<br /> I / e \EAVE VFNTING DIAGRAM 7 REFER TOSHEETAD3OFOR oot
<br /> b-
<br /> 0
<br /> 0 1 12'-1'-O' PENETRATION REQUIREMENTS IN REGISTERED
<br /> FIRE RATED CONSTRUCTION. ARCHITECT
<br /> �\,\�\\ \\��1p;/12 70/12' \� \&N�\. 10'/12 10./12' \��\ N\� ATTIC VENTILATION CALCULATIONS 8 LEVELS 1-3 CONSTRUCTION TYPE VB,
<br /> \�\\\\\\\�\x\`!1` I \`\\\�\ �\`_iwk\\\ ,1 \I`��\\\\\\\\\\\\` ATTIC AREA 1:250,042 S.I(1,736.4 SF) OCCUPANCIES R-2 S-2 \_.
<br /> 1\`` \I� 1` 000 1 -- CEILING ASSEMBLY AT BOTTOM CHORD OF ROOF TRUSSES INCLUDES FFREY ARTHUR WILLIAM
<br /> DS �\ -`i` 1 DS n ��\� m�` DS CLASS II VAPOR BARRIER.REQUIRED VENTILATION @ 1/300(IBC 9. ALL LEVELS FULLY SPRINKLERED PER STATE Or w HINGTON
<br /> SECTION 1203.2 EXCEPTION):833.5 S.I.(5.8 S.F.)
<br /> IBC SECTION 903.3.1.1(NFPA 13).
<br /> 10. UNIT DEMISING WALLS ARE 1-HOUR
<br /> EAVE VENTILATION 166'L.F.(1,176 L.I.) RATED PER IBC SECTION 708 W/
<br /> AI
<br /> ICE E D 24 SHIELD,ACTIP. BIRD BLOCKING WITH THREE 2"DIAMETER HOLES PER TRUSS MINIMUM STC 50,
<br /> VIP OF
<br /> 24"BEYOND FACE BAY W/1/8"MESH SCREEN 2.50 S.I.(.0174 S.F.)NFA PER NOTCH.
<br /> OF EXTERIOR WALL SEE SEE DIAGRAM 1/A501 3.75 S.I.(.026 S.F.)NET FREE AREA PER 11. DIMENSIONS ARE TO OUTSIDE EDGE OF
<br /> 3BE4.0 LINEAL FOOT=622.5 S.I.(4.32 S.F.)TOTAL CONCRETE OR FACE OF STUD,TYP.
<br /> / o \BSI DING H-ROOF CONTINUOUS RIDGE VENTILATION:34 L.F. 12. SEE STRUCTURAL DRAWINGS
<br /> COR-A-VENT REVOLUTION @ 12 S.I.NET PER FT.=34 FT'12 FOR ROOF FRAMING.
<br /> 1/8"=1'-0" S.I./FT=408 S.I.(3 S.F.)TOTAL
<br /> 13. ALL ROOFING TO BE CLASS B
<br /> TOTAL PROVIDED VENTILATION:367.5 S.I+504 S.I+318 S.I.+264 S.I.= MINIMUM PER IBC SECTION 1505
<br /> 1,453.5 S.I.(70.09 S.F.) AND TABLE 1505.1.
<br /> T •
<br /> SAVE&SOFFIT VENTS:(622.5/833.5)'100=74.7% 14. ALL ROOF SLOPES ARE 5/12 U.N.O. p
<br /> HIGH VENTS:(408/833.5)'700=48.9% STEP GARAGE FOOTINGS&SLABS
<br /> 15. DRAFTATTICS ORO ARE REQUIRED IN
<br /> D n
<br /> Aiii) O AS REQUIRED FOR GRADE CHANGE O ATTICS OTHER CONCEALED °
<br /> / 72•_1• / m
<br /> ROOF SPACES PER IBC SECTION p
<br /> 716.az. r 5
<br /> 72'-1" / / / / 16. PER IBC SECTION 708.4,IN COMBUSTIBLE
<br /> 3'-1 12" 7 12" CONSTRUCTION WHERE THE FIRE E
<br /> 5'-712" 6'-112" 3'-112" 6'-112" 5'-
<br /> 11' 6" / / / / / / / / / / / E
<br /> PARTITIONSCONTINUOUS
<br /> NOTHE SHEET ITON b
<br /> V / / 1 BE CONTINUOUS TO THE SHEATHING,
<br /> UNE OF AIR BARRIER r __ DECK OR SLAB,THE SPACE E
<br /> DS l_ - _ DECK OR SLAB a
<br /> BETWEEN THE CEILING AND THE
<br /> :may-a.R�a:= -:�: SHEATHING ABOVE
<br /> :� H H �'v H H O SHALL BE FIRE BLOCKED OR
<br /> • .5 /� DS O DS O 1`� © T O DS 7A O DS
<br /> 7O iv Ilk
<br /> L- --/ 1 17�\ _ _ _ DRAFTSTOPPED IN ACCORDANCE
<br /> r / �'��..C1WITH IBC SECTIONS 718.2 AND o
<br /> I� • 718.3 AT THE PARTITION LINE.
<br /> ----0 o----' `--� _$___ �}- a 0-----� EXCEPTION WS:ATTIC FIREBLOCKING OR
<br /> iiIFAIIMMI
<br /> ^ IV 1 _ 7A DRAFTSTOPPING IS NOT REQUIRED AT THE
<br /> PARTITION LINE IN GROUP R-2 BUILDINGShI' - pp_�___ 78 THAT DO NOT EXCEED FOUR STORIES ABOV711
<br /> -o a UNIT 5.1 - im UN © o GARAGE 1 GARAGE 2 _ 1 tli GARAGE 5 GARAGE 6 © S 3UBD V TED DRAFTSTOPPING INTOACE ISSUE DATE 07/19/19
<br /> AREAS I E
<br /> -{ GARI."- GARAGE4 3,000 SF OR
<br /> E
<br /> ' 2N ' --_ 12/A150 J --- 1 I' LIT 5. - %IV I -- -- ry-- --- }� _ - - ----' ---- ® EVERY TWO DWELLING UNITS,WHICHEVERB
<br /> TI
<br /> N I 2/A150 m f b .. FACP\ IS SMALLER.
<br /> + 1j 1 .�I 6,��P `I
<br /> '� ��- „ -■. �' - -, -PRINKLER 17. 2"GYP,SHEATHING TOR 1/2"ERIALS TO BE
<br /> PLYWOOD OR OSB SHEATHING PER
<br /> MEN
<br /> oS 11 6DS „ 11 6' -(/''�' 0
<br /> 0
<br /> 0 I=' - /''�I IBCSECTIONING S1.
<br /> © .�1100 ' _ham � � �/ © -- _- }- O- �J O \l - �/
<br /> - ___ _ ui 79. DRAFTSTOPPING SHALL BE
<br /> 'o -- `--'--- - - - -' d 2 u-.J T'a d INSTALLED ABOVE,AND IN UNE WITH
<br /> e 4 2
<br /> is -- 41•• 5'-6" 5-6" 5'-6" 5'-6" 5'-fi"
<br /> SLEEPING UNIT AND DWE W NG UNIT
<br /> I
<br /> /S .�' D / ,�' ,�' ,�' 4 DS/ SEPARATION WALLS THAT DO NOT
<br /> 6-1" 33-0 EXTEND TO THE UNDERSIDE OF THE
<br /> / 1 / /
<br /> ROOF SHEATHING ABOVE PER IBC
<br /> - 0 a 16'SIMPSON T18"R NGWA N SECTION 718.4.2.
<br /> 0 0 STRONGWALL a a STRONGWALL L O EXCEPTION i13:IN OCCUPANCIES IN GROUPVP
<br /> PER PER A THAT NOTEXCEED FOUR STORIES MY
<br /> STRUCTURALVIV STRUCTURAL ABOVE GRADE PLANE,THE ATTIC SPACE
<br /> SHALL BE SUBDIVIDED BY DRAFTSTOPS INTO
<br /> AREAS NOT EXCEEDING 3,000 SF OR ABOVE 3
<br /> EVERY TWO DWELLING UNITS,WHICHEVER IS S
<br /> C SMALLER. 1
<br /> ��BUILDING H-FLOOR 3 0/2�BUILDING H-FLOOR 1
<br /> V 1/8'=1'-0' \I`n>V 1/8"=1'-0" 20. PER IBC SECTION 1203.2 EXCEPTION: V
<br /> THE NET FREE CROSS-VENTILATION AREA
<br /> o O OT SHALL BE PERMITTED TO BE REDUCED TO w 3
<br /> 1/300 PROVIDED BOTH OF THE FOLLOWING
<br /> CONDITIONS ARE MET:
<br /> / / 1.IN CLIMATE ZONES 6,7,AND 8,A CLASS I g
<br /> w 72'-I" OR II VAPOR RETARDER IS INSTALLED ON > 6
<br /> c / / I I THE WARM-IN-WINTER SIDE OF THE CEILING. N 6
<br /> O LINE OF AIR BARRIER / 72-1 / 2.AT LEAST 40 PERCENT AND NOT MORE
<br /> cap - 33'-6" 5'-1" 33'-6' THAN 50 PERCENT OF THE REQUIRED = w &
<br /> IE
<br /> / / / / VENTING AREA IS PROVIDED BY j
<br /> - 7A�1 VENTILATORS LOCATED IN THE UPPER L' w
<br /> ' °r EMERGENC Il GI ESS t ~� o PORTION OF THE ATTIC A RAFTER SPACE. G ? g 0I I
<br /> MI 'off __'----.-o-__ �-_ ,.-�.,_ 1 UPPER VENTILATORS SHALL BE LOCATED �Q a
<br /> tV /1 DS _ _ - _ _ _ - _ DS __ O _ _ /� NOT MORE THAN 3 FEET BELOW THE RIDGE 3 pg
<br /> p ( 1 `"� r--- I I•- C 1 1 \ -__ ___ __ _ ___ __ --( 1 ) OR HIGHEST POINT OF THE SPACE, OS
<br /> yk €g
<br /> rn II•��•iY - - -- -- - - - �- - ,_ - - - - -- - - - �J MEASURED VERTICALLY,WITH THE BALANCE �w $:
<br /> 1 ppp 1 OF THE VENTILATIO NPROVIDED BY SAVE OR
<br /> _ 0 } LIGHTING ;!, �p LIGHTING LITHONIA } II I Q n'w N rA
<br /> M pp CORNICE VENTS.WHERE THE LOCATION OF R.> P
<br /> LITHONIA EL 2 1 VGR1 I _ r!W
<br /> E ;I II I WALL OR ROOF FRAMING MEMBERS rn o0
<br /> to UNIT 5.1 1 7C f 1 7C UNIT 5.1 CONFLICTS WITH THE INSTALLATION OF rn z = o ff B
<br /> U ( IIi. 1 II UPPER VENTILATORS,INSTALLATION MORE _d w a m§LL 6 0
<br /> 1/A150 I 1/A150 THAN 3 FEET BELOW THE RIDGE OR p a u ;
<br /> 1 Inn
<br /> © III HIGHEST POINT OF THE SPACE SHALL BE •� Q J gam
<br /> 1 3 [fill]
<br /> 1 PERMITTED.
<br /> ' •�� MY m II \ If d w 3mzv< o
<br /> um (0 �[Z] ' O o r 21. BATHROOMS SHALL BE 3 'm N >H=
<br /> In yp-- LZ] I "• .yp-- II MECHANICALLY VENTILATED IN 2N
<br /> --- --- 'II - - I ACCORDANCE WITH THE IMC PER IBC Lat. u O rc m ag
<br /> _ct--- m . v ---- 1 cO b a I SECTION 1203.6.2.1.
<br /> ���-os J - Ds. l� i -- L- ( L J' _ ___ LIGHTING LEGEND
<br /> E 2 �J _ __�- _-O O.\ --_��---.��--}-Fl _ _-P_�----�_�_-_�_ _ i- 2 PROJECT#. 1705
<br /> V 1 ry DS LITHONIA VGRI,3.7"DEEP PER DRAWN BY: AT
<br /> O "'\ hi' 1„ 'I r MANUFACTURER.
<br /> CHECKED BY: ST
<br /> t I23'-1" 7'-6" 17'-0" / / / / TO BE USED AS EGRESS
<br /> • H / / / LIGHTING PER IBC SECTION
<br /> w O a O O B PHOTOCELL TO
<br /> T ENSURE S BY
<br /> LEVELS OUREUGHT BUILDING PLANS-
<br /> Li OF 1
<br /> VP ___/
<br /> J FOOTCAND EIN.AT THE WALKING CARRIAGE H
<br /> UTHONIA ELM 2-LED,3 5/8"
<br /> �� 1 DEEP PER MANUFACTURER.
<br /> (r i\ BUD DING H-FLOOR 2 0( '\BUILDING H-FOUNDATION �''- TO BE USED AS EMERGENCY
<br /> \I`n>V 7/8'=1'-0" FLIXTURE TOP R PROVBC IDE
<br /> MIIPI ON
<br /> A217
<br /> 1008.3.BATTERY BACK-UP IN
<br /> w FIXTURE PROVIDE MIN.90
<br /> MINUTES OF ILLUMINATION IN
<br /> ,� FAILURE,NT OF A POWER BID/CONSTRUCTION