Laserfiche WebLink
46.28.130". Location shall be approved by the Fire Code Official. Per Fire Marshal site <br />visit. <br />5. Premise Identification - Premises shall be clearly identified by the correct address at the <br />street entry. Buildings shall be clearly identified so as to be visible and legible from the <br />access road. Individual apartments and suites, where applicable, shall be clearly and legibly <br />identified from the access road. EMC 16.03, Section 505.1.1 (Address Posting Policy). 16" <br />numbers to be placed on building. <br />6. Fire Hydrants - Locations as planned are acceptable. <br />7. Fire flow for this project is 1,500 GPM. <br />8. Portable Fire Protection -A portable fire extinguisher with a minimum U.L. rating of 2-A:10- <br />B:C shall be provided within 75 feet of travel on all floors of each building during <br />construction and prior to occupancy. 2015 IFC, Section 906 <br />9. Kitchens - Install a K-type fire extinguisher within 30 feet of the grill and deep fryers. 2015 <br />IFC, 904.12.5.2 <br />10. Commercial Cooking Operations - A ventilating hood and duct system with an approved <br />automatic fire -extinguishing system shall be provided in accordance with the Mechanical <br />Code for commercial -type food heat -processing equipment that produces grease -laden <br />vapors. Note: If class 1 hood system is installed. <br />11. Fire Alarm System - An approved automatic fire detection system shall be provided as <br />required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. <br />Plans for such system shall be submitted to the Fire Code Official for review and approval <br />prior to installation. Submittal shall include cut sheets of all equipment intended for use. <br />Appropriate trip tests, witnessed by a Fire Department Inspector, shall be performed, along <br />with a certificate of completion, prior to final acceptance of the system. , <br />Fire alarm systems shall be installed according to NFPA Chapter 72, 2013 Edition. <br />Installation of fire alarm components, including basic wiring, may not commence <br />before plans are approved by the Fire Department Plan Reviewer. Fire alarm drawings <br />must be professionally rendered, in sufficient detail, and must be internally consistent. Riser <br />diagrams must match installation plans and load calculations. Components must be listed <br />and approved for use together. Changes to plans must include new drawings and calculations <br />and must be approved by the Fire Department Plan Reviewer prior to installation. Fire alarm <br />installation is subject to field inspection by a Fire Department Inspector. An approved set of <br />plans and the Engineering & Public Services Department electrical permit must be present <br />for any installation inspection. <br />Fire alarm systems shall be installed under permit of the City of Everett Engineering & <br />Public Services Department. Electrical inspections and approval are required prior to calling <br />for acceptance tests. Call (425) 257-8810 for permit information. <br />The absence of monitoring for the alarm system will be cause for postponing Fire <br />Department inspection and testing and shall result in denial of occupancy. <br />SP 008 <br />Page 5 of 10 � <br />