My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2514 RAINIER AVE 2022-03-01
>
Address Records
>
RAINIER AVE
>
2514
>
2514 RAINIER AVE 2022-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2022 10:45:56 AM
Creation date
6/9/2021 10:17:56 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
2514
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
other equipment. For details, call the Everett Fire Department Plan Reviewer at (425) 257- <br />8124. <br />15. Floors and sub -floors at or above grade in buildings (other than parking garages) shall be <br />marked with numbers, in ascending order, beginning with the number "1" (for the ground <br />floor or first floor), then "2", "3", etc. Letters shall be used only to designate specific areas <br />as detailed below. <br />Floors below grade in buildings (other than parking garages) shall be marked with the letter <br />"B" (when there is only one floor below grade). When there is more than one floor below <br />grade, they shall be marked with the letter "B" followed by numbers, in descending order, <br />beginning with the number "1" (for the floor immediately below the ground floor or first <br />floor), then "2", "3", etc. Example — "B 1 ", "13213, "133 ", in descending order. <br />Mezzanines shall be marked with the letter "M". When there is more than one mezzanine, <br />they shall be marked with the letter "M" followed by numbers, in ascending order. Example <br />—"M1", "M2", etc. <br />Parking garages shall use the letter "P" to designate floors. <br />When there is only one parking level at or above grade, it shall be marked with the letter "P". <br />When there is more than one parking level at or above grade, they shall be marked with the <br />letter "P" followed by numbers, in ascending order. Example — "Pl" "P2", etc. <br />When there is only one parking level below grade, it shall be marked "P01 When there is <br />more than one parking level below grade, they shall be marked with the letter "P" followed <br />by numbers, in descending order. Example — "PO1 ", "P02", etc. <br />Large parking structures may use letters to designate columns for ease of locating <br />automobiles. I Example —"Floor P3, Column E". <br />16. A floor map shall be included at each stair landing (I I" x 17" size) and at each elevator <br />landing (16" x 20" size) showing the layout and room numbering of the floor. <br />17. Stairwell signs shall be designed per Everett Fire Marshal Policy. Go to www.everettfire.org <br />to view the policy. <br />18. All fire alarm control panels (FRCP) and sprinkler valves shall be in heated rooms or closets <br />with standard man door access. Locations shall be approved by the Fire Code Official <br />(NFPA 13, 2013 edition, section 8.16.4.1.3). <br />19. The location of Fire Department connections (FDC) and post indicator valves (PIV) shall be <br />determined by the Fire Code Official. If immediate outside man door access is available to <br />the sprinkler valves (risers), a PIV will not be required. Location on site plan is approved. <br />20. Trash Collection - Dumpsters over 1.5 cubic yards capacity shall be located a minimum of 5 <br />feet from the building (2015 IFC 304.3.3 and 304.3.4). <br />21. Where elevators are provided in buildings, at least one elevator shall be provided for fire <br />department emergency access to all floors. The elevator car shall be of such a size and <br />SPU17-008 <br />-17 <br />Page 7 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.