My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6009 FLEMING ST 2021-06-09
>
Address Records
>
FLEMING ST
>
6009
>
6009 FLEMING ST 2021-06-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2021 2:47:03 PM
Creation date
6/9/2021 2:44:51 PM
Metadata
Fields
Template:
Address Document
Street Name
FLEMING ST
Street Number
6009
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
160
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Popach Short Plat—2 Lots <br /> Table V-4.5.2(5) Maintenance Standards - Catch Basins (continued) <br /> Results <br />• <br /> Maintenance Conditions When Maintenance is Expected <br /> Defect When Main- <br /> Component Needed tenance is <br /> performed <br /> Frame not sitting flush on top slab, i.e., sec- ting flush on <br /> aration of more than 3/4 inch of the frame the riser rings <br /> from the top slab.Frame not securely or top slab <br /> attached and firmly <br /> attached. <br /> Basin <br />• Maintenance person judges that structure is replaced or <br /> unsound. repaired to <br /> Fractures or design stand- <br /> Cracks in Grout fillet has separated or cracked wider <br /> Basin Walls/ <br /> ands. <br /> than 1/2 inch and longer than 1 foot at the <br />• Bottom joint of any inlet/outlet pipe or any evidence Pipe is <br /> of soil particles entering catch basin through regrouted <br /> cracks. and secure at <br /> basin wall. <br /> Basin <br />• Settlement/ If failure of basin has created a safety,func- replaced or <br /> Misalignment tion, or design problem. repaired to <br /> design stand- <br /> ards. <br /> No veget- <br />• Vegetation growing across and blocking anion block <br /> more than 10% of the basin opening. ing opening <br /> to basin. <br /> Vegetation Vegetation growing in inlet/outlet pipe joints No veget- <br /> that is more than six inches tall and less <br /> than six inches apartation or root <br />• growth <br /> present. <br /> Contamination „ No pollution <br /> and Pollution See Detention Ponds (No. 1). present. <br /> Cover Not in Cover is missing or only partially in place. Catch basin <br />• Catch Basin Place Any open catch basin requires main- cover is <br /> Cover tenance. closed <br /> Locking Mech-Mechanism cannot be opened by one main- Mechanism <br /> anism Not tenance person with proper tools. Bolts into opens with <br />• <br /> 2014 Stormwater Management Manual for Western Washington <br /> Volume V- Chapter 4 -Page 839 <br /> WESTERN ENGINEERS,INC. 21 PROJECT:15-1463-A <br />
The URL can be used to link to this page
Your browser does not support the video tag.