My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7505 SEAWAY BLVD BUS SHELTER 2 2021-06-10
>
Address Records
>
SEAWAY BLVD
>
7505
>
BUS SHELTER 2
>
7505 SEAWAY BLVD BUS SHELTER 2 2021-06-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2021 1:18:35 PM
Creation date
6/10/2021 1:14:29 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
7505
Tenant Name
BUS SHELTER 2
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> SYMBOLS: <br /> ABBREVIATIONS: GENERAL NOTES: <br /> ALUM ALUMINUM SIM SIMILAR DETAIL DESIGNATOR <br /> AFF ABOVE FINISHED FLOOR SJ SCORE JOINT 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 2015 INTERNATIONAL BUILDING CODE. A COPY OF THE APPROVED PLAN SHALL BE <br /> ARCH ARCHITECT,ARCHITECTURE SOG SLAB ON GRADE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. <br /> @ AT SST STAINLESS STEEL r 1 <br /> AVE AVENUE STRUCT STRUCTURE OR STRUCTURAL I I 2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN <br /> BATT BATTEN THK THICK,OR THICKNESS I I AND TO FURTHER DISCOVER AND AVOID HARM TO ANY OTHER BUILDING UTILITIES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY <br /> BLD BUILDING TOC TOP OF CURB J THE IMPLEMENTATION OF THIS PLAN. <br /> B.O.S. BOTTOM OF STRUCTURE TOR TOP OF RAIL <br /> BOT BOTTOM TRD TREAD 0C AREA OF IMAGE 3. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS REQUIRED TO PROTECT EXISTING UTILITIES,EQUIPMENT OR BUILT-IN FURNISHINGS <br /> CAB CABINET TYP TYPICAL REMAINING IN THE WORK AREA DURING CONSTRUCTION. <br /> CCTV CLOSED CIRCUIT TELEVISION UNO UNLESS NOTED OTHERWISE SHEET NUMBER WHERE <br /> CES CUSTOMER EMERGENCY STATION VERT VERTICAL THE DETAIL IS SHOWN 4. ALL DEMOLITION DEBRIS SHALL BE LEGALLY DISPOSED OF,OFF SITE. <br /> CIP CAST IN PLACE VIF VERIFY IN FIELD (DASH IF ON SAME SHEET ONLY) <br /> CJ CONSTRUCTION JOINT W/ WITH 5. DO NOT SCALE THE DRAWINGS. <br /> COL COLUMN W/O WITHOUT <br /> COMM COMMUNICATION(S) 9. OVERALL DIMENSIONS INDICATED ARE TO FINISH SURFACES OR STRUCTURAL GRID-LINES AND OTHER DIMENSIONS ARE TO FACE OF <br /> CONC CONCRETE CAST IN PLACE CONCRETE,OR FACE OF STRUCTURE UNLESS NOTED OTHERWISE. <br /> CONST CONSTRUCTION <br /> CONT CONTINUOUS SYMBOLS: 10. DRAWING SCALES SHOWN ARE BASED ON A SHEET-SIZE OF 34 X 22 INCHES.IF THE PRINTED SHEET SIZE IS 17 X 11 INCHES,THEN THE • <br /> D DEPTH DRAWINGS HAVE BEEN REDUCED TO HALF THE SCALE INDICATED. <br /> DET,DTL DETAIL DIA DIAMETER DRAWING DESIGNATOR 11. THE DRAWINGS AND SPECIFICATIONS TOGETHER COMPRISE THE CONSTRUCTION DOCUMENTS. ANY DISCREPANCIES BETWEEN THEM <br /> DIM DIMENSION . • OR BETWEEN TWO OR MORE DRAWINGS SHALL BE REFERRED TO THE RESIDENT ENGINEER BEFORE ANY WORK AFFECTED IS <br /> DN DOWN PERFORMED. <br /> �( <br /> DWG(S) DRAWING(S) DRAWING TITLE/NAME <br /> EA EACH XXXXX SCALE: 12. SEE CIVIL DRAWINGS FOR LAYOUT AND DETAILS OF PAVEMENTS AND CURBS. <br /> EJ EXPANSION JOINT �� <br /> ELEV ELEVATION SHEET NUMBER WHERE DRAWING 13. SEE DRAINAGE DRAWINGS FOR UNDERGROUND PIPING INFORMATION. <br /> ELEC ELECTRICAL IS CALLED OUT GRAPHICS LEGEND: <br /> EQ EQUAL 14. SEE STRUCTURAL DRAWINGS FOR STRUCTURAL ELEMENTS AND ATTACHMENT INFORMATION. <br /> EXIST EXISTING -- <br /> EXT EXTERIORCIP CONCRETE(PLAN,SECTION,AND 15. SEE MECHANICAL DRAWINGS FOR MECHANICAL AND PLUMBING INFORMATION. 'DESIGNATORFE FIRE EXTINGUISHERELEVATION) <br /> FEC FIRE EXTINGUISHER CABINET16. SEE ELECTRICAL DRAWINGS FOR TYPE OF INTERIOR LIGHTING LOCATION,SEE CIVIL DRAWINGS FOR EXTERIOR LIGHTING LOCATIONS <br /> FIXT FIXTURE <br /> FT FOOT OR FEETPRECAST CONCRETE(PLAN,SECTION, 17. FOR COLORS AND FINISHES,SEE SPEC 090600 COLORS AND FINISHES SCHEDULE.BRING ANY DISCREPANCIES BEWEEN <br /> F.O.C. FACE OF CONCRETE OR FACE OF CURB D1DRAWING <br /> WING TITLE/NAME AND ELEVATION) SPECIFICATION SECTIONS AND BETWEEN SPECS AND DRAWINGS TO THE ATTENTION OF THE OWNER. <br /> F.O.I.C. FURNISHED BY OWNER,INSTALLED BY CONTRACTOR SC <br /> F.O.S. FACE OF STEEL 18. PROVIDE 8 FOOT MINIMUM CLEARANCE FROM GRADE TO UNDERSIDE OF CANOPY STRUCTURE. <br /> GA GAUGE MORTAR/GROUT FILL <br /> GALV GALVANIZED DRAWING SHOWN ON <br /> z GL GLASS SAME SHEET ONLY <br /> 0 GWB GYPSUM WALL BOARD <br /> HDWR HARDWARE //// STEEL SHEET LIST TABLE PROJECT INFORMATION <br /> m HORZ HORIZONTAL SECTION DESIGNATOR 2015 INTERNATIONAL BUILDING CODE <br /> m HR HOUR Sheet Number Sheet Title <br /> ¢ % OCCUPANCY <br /> �a HM HOLLOW METAL A0.1 LEGEND&ABBREVIATIONS <br /> 9 HSS HOLLOW STRUCTURAL SECTION(STEEL) jjj� ALUMINUM <br /> w HT HEIGHT A1.0 SITE PLAN BUILDINGh. CONSTRUCTION:Vf <br /> W IBC INTERNATIONAL BUILDING CODE X)()()(XX A3.0 FULL SHELTER ��� " <br /> ,E, IN INCH �/``—SHEET NUMBER WHERE THE PROJECT INCLUDES: <br /> Z RIGID INSULATION (PLAN AND SECTION) A3.1 NARROW SHELTER <br /> • INFO INFORMATION SECTION IS SHOWN 2 FULL SHELTERS: <br /> R INSUL INSULATION A3.2 SHELTER SECTIONS 432 SF <br /> JB JUNCTION BOX A3.3 SHELTER DETAILS <br /> -F JT JOINT CONTINUOUS BLOCKING A3.4 SHELTER DETAILS J OW-5HEIXE3S. <br /> 8 LED LIGHT-EMITTING DIODE ELEVATION DESIGNATOR - ,k2t--5- <br /> MAX MAXIMUM A4.0 PLANS AND ELEVATIONS <br /> P MECH MECHANICAL A4.1 WIND SCREEN DETAILS <br /> MFR MANUFACTURER \ NON CONTINUOUS BLOCKING <br /> a MIN MINIMUM <br /> — MOW MAINTENANCE OF WAY J <br /> MT <br /> XX‘ <br /> N/A NOT APPLICABLE <br /> 3 METAL SHEET NUMBER WHERE THE SEALANT AND BACKER ROD <br /> N/A <br /> NIC NOT IN CONTRACT ELEVATION IS SHOWN <br /> NO NUMBER <br /> S N.T.S NOT TO SCALE <br /> `" 0/ OVER GLASS/GLASS BLOCK <br /> in OC ON CENTER DETAIL DESIGNATOR <br /> OPNG OPENING <br /> OPP OPPOSITE <br /> H PET PHONE&TELEPHONE DETAIL TACTILE WARNING TILE <br /> PC PRECAST XXXXX SCALE: <br /> PERF PERFORATED ��� <br /> PERIM PERIMETER <br /> PGL PROFILE GRADE LEVEL SHEET NUMBER WHERE THE <br /> .1. PLYWD PLYWOOD DETAIL IS SHOWN <br /> o PLAT PLATFORM <br /> PRV PRESSURE REDUCING VALVE <br /> 3 PT PAINT DETAIL DESIGNATOR <br /> AI <br /> R RADIUS OR RISER CITI( OF EVERETT <br /> o R- R-VALUE <br /> f RCP REFLECTED CEILINGPLAN X DETAIL REVIEWED FOR PERMIT <br /> REQD REQUIRED SCALE: <br /> RO ROUGH OPENING <br /> SECT SECTION DETAIL SHOWN ON THE <br /> SHT SHEET SAME SHEET ONLY <br /> E COMMUNITY TRANSIT Drawing No. <br /> 3507 Drawn By Date SCALE <br /> r� IBIGROUP --- REGISTER KC 9/30/19 A0. 1 <br /> 801 Second Avenue-Suite 1000 0' 0 o 1 ARC I PERMIT Designed By Hora SEAWAY TRANSIT CENTER — SHELTER—ADDITIONS <br /> Seattle WA 98104 USA communitytrarl5lt MM 9/30/19 NTS Sheet No. <br /> ""--- o GR RY L HILL SET Checked By Vert <br /> S - tel 206 521 9091 fax 208 521 9095 •x GH 9/30/19 N/A <br /> c 1 1 ibi rou com Sti1j),,&:'' STAT F WASHINGTON 1 <br /> —• No. Dote — Revision By Appr. 9 P Approved By Project Number <br /> LEGEND & ABBREVIATIONS of g tel <br /> O <br />
The URL can be used to link to this page
Your browser does not support the video tag.