My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7505 SEAWAY BLVD BUS SHELTER 8 2021-06-10
>
Address Records
>
SEAWAY BLVD
>
7505
>
BUS SHELTER 8
>
7505 SEAWAY BLVD BUS SHELTER 8 2021-06-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2021 2:15:34 PM
Creation date
6/10/2021 2:10:36 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
7505
Tenant Name
BUS SHELTER 8
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYMBOLS: <br /> ABBREVIATIONS: GENERAL NOTES: <br /> ALUM ALUMINUM SIM SIMILAR DETAIL DESIGNATOR <br /> AFF ABOVE FINISHED FLOOR SJ SCORE JOINT 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 2015 INTERNATIONAL BUILDING CODE. A COPY OF THE APPROVED PLAN SHALL BE <br /> ARCH ARCHITECT,ARCHITECTURE SOG SLAB ON GRADE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. <br /> @ AT SST STAINLESS STEEL r 1 <br /> AVE AVENUE STRUCT STRUCTURE OR STRUCTURAL I I 2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN <br /> BATT BATTEN THK THICK,OR THICKNESS I I AND TO FURTHER DISCOVER AND AVOID HARM TO ANY OTHER BUILDING UTILITIES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY <br /> BLD BUILDING TOC TOP OF CURB aa J THE IMPLEMENTATION OF THIS PLAN. <br /> B.O.S. BOTTOM OF STRUCTURE TOR TOP OF RAIL N-AREA OF IMAGE <br /> BOT BOTTOM TRD TREAD XX.XXXJC� 3. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS REQUIRED TO PROTECT EXISTING UTILITIES,EQUIPMENT OR BUILT-IN FURNISHINGS <br /> CAB CABINET TYP TYPICAL REMAINING IN THE WORK AREA DURING CONSTRUCTION. <br /> CCTV CLOSED CIRCUIT TELEVISION UNO UNLESS NOTED OTHERWISE SHEET NUMBER WHERE <br /> CES CUSTOMER EMERGENCY STATION VERT VERTICAL THE DETAIL IS SHOWN 4. ALL DEMOLITION DEBRIS SHALL BE LEGALLY DISPOSED OF,OFF SITE. <br /> CIP CAST IN PLACE VIF VERIFY IN FIELD (DASH IF ON SAME SHEET ONLY) <br /> CJ CONSTRUCTION JOINT W/ WITH 5. DO NOT SCALE THE DRAWINGS. <br /> COL COLUMN W/O WITHOUT <br /> COMM COMMUNICATION(S) 9. OVERALL DIMENSIONS INDICATED ARE TO FINISH SURFACES OR STRUCTURAL GRID-LINES AND OTHER DIMENSIONS ARE TO FACE OF <br /> CONC CONCRETE CAST IN PLACE CONCRETE,OR FACE OF STRUCTURE UNLESS NOTED OTHERWISE. <br /> CONST CONSTRUCTION <br /> CONT CONTINUOUS SYMBOLS: 10. DRAWING SCALES SHOWN ARE BASED ON A SHEET SIZE OF 34 X 22 INCHES.IF THE PRINTED SHEET SIZE IS 17 X 11 INCHES,THEN THE <br /> D DEPTH DRAWINGS HAVE BEEN REDUCED TO HALF THE SCALE INDICATED. <br /> DET,DTL DETAIL <br /> DIA DIAMETER DRAWING DESIGNATOR 11. THE DRAWINGS AND SPECIFICATIONS TOGETHER COMPRISE THE CONSTRUCTION DOCUMENTS. ANY DISCREPANCIES BETWEEN THEM <br /> DIM DIMENSION OR BETWEEN TWO OR MORE DRAWINGS SHALL BE REFERRED TO THE RESIDENT ENGINEER BEFORE ANY WORK AFFECTED IS <br /> DN DOWN X DRAWING TITLE/NAME PERFORMED. <br /> DWG(S) DRAWING(S) <br /> EA EACH XXXXX SCALE: 12. SEE CIVIL DRAWINGS FOR LAYOUT AND DETAILS OF PAVEMENTS AND CURBS. <br /> EJ EXPANSION JOINT �/ <br /> ELEV ELEVATION SHEET NUMBER WHERE DRAWING 13. SEE DRAINAGE DRAWINGS FOR UNDERGROUND PIPING INFORMATION. <br /> ELEC ELECTRICAL IS CALLED OUT GRAPHICS LEGEND: <br /> EQ EQUAL 14. SEE STRUCTURAL DRAWINGS FOR STRUCTURAL ELEMENTS AND ATTACHMENT INFORMATION. <br /> EXIST EXISTING <br /> EXT EXTERIOR DRAWING DESIGNATOR CIP CONCRETE(PLAN,SECTION,AND 15. SEE MECHANICAL DRAWINGS FOR MECHANICAL AND PLUMBING INFORMATION. <br /> FE FIRE EXTINGUISHER ELEVATION) <br /> FEC FIRE EXTINGUISHER CABINET 16. SEE ELECTRICAL DRAWINGS FOR TYPE OF INTERIOR LIGHTING LOCATION,SEE CIVIL DRAWINGS FOR EXTERIOR LIGHTING LOCATIONS <br /> FIXT FIXTURE <br /> FT FOOT OR FEET PRECAST CONCRETE(PLAN,SECTION, 17. FOR COLORS AND FINISHES,SEE SPEC 09 06 00 COLORS AND FINISHES SCHEDULE.BRING ANY DISCREPANCIES BETWEEN <br /> F.O.C. FACE OF CONCRETE OR FACE OF CURB DRAWING TITLE/NAME AND ELEVATION) SPECIFICATION SECTIONS AND BETWEEN SPECS AND DRAWINGS TO THE ATTENTION OF THE OWNER. <br /> F.O.I.C. FURNISHED BY OWNER,INSTALLED BY CONTRACTOR SCALE: <br /> F.O.S. FACE OF STEEL 18. PROVIDE 8 FOOT MINIMUM CLEARANCE FROM GRADE TO UNDERSIDE OF CANOPY STRUCTURE. <br /> GA GAUGE MORTAR/GROUT FILL <br /> GALV GALVANIZED DRAWING SHOWN ON <br /> on GL GLASS SAME SHEET ONLY <br /> s GWB GYPSUM WALL BOARD <br /> HDWR HARDWARE / STEEL SHEET LIST TABLE PROJECT INFORMATION <br /> m HORZ HORIZONTAL SECTION DESIGNATOR 2015 INTERNATIONAL BUILDING CODE <br /> m HR HOUR Sheet Number Sheet Title <br /> HM HOLLOW METAL A0.1 LEGEND&ABBREVIATIONS OCCUPANCY 4j/�j ALUMINUM <br /> w HSS HOLLOW STRUCTURAL SECTION(STEEL) BUILDING CONSTRUCTION:V <br /> l7w HT HEIGHT A1.0 SITE PLAN aCC.- ® L 2-(1 <br /> ▪ IBC INTERNATIONAL BUILDING CODE XXXXXX A3.0 FULL SHELTER <br /> IN INCH \.�'. —SHEET NUMBER WHERE THE }kx� <br /> RIGID INSULATION (PLAN AND SECTION) A3.1 NARROW SHELTER PROJECT INCLUDES: <br /> INFO INFORMATION SECTION IS SHOWN2.4.14/1.66HELIF.R5d <br /> INSUL INSULATION A3.2 SHELTER SECTIONS <br /> JB JUNCTION BOX A3.3 SHELTER DETAILS <br /> JT JOINT CONTINUOUS BLOCKING A3.4 (4)NARROW SHELTERS: <br /> LED MAX MAXIMUM LIGHT-EMITTING DIODE ELEVATION DESIGNATOR SHELTER DETAILS 120 SF <br /> Zi V° A4.0 PLANS AND ELEVATIONS <br /> MECH MECHANICAL A4.1 WIND SCREEN DETAILS ' <br /> s 1 <br /> MFR MANUFACTURER A�j \ NON CONTINUOUS BLOCKING <br /> • MIN MINIMUM ir <br /> ▪ MOW MAINTENANCE OF WAY <br /> 3 MTL METAL .•. � <br /> N/A NOT APPLICABLE SHEET NUMBER WHERE THE ( SEALANT AND BACKER ROD <br /> NIC NOT IN CONTRACT ELEVATION IS SHOWN <br /> - NO NUMBER <br /> S N.T.S NOT TO SCALE <br /> 0/ OVER GLASS/GLASS BLOCK <br /> u OC ON CENTER DETAIL DESIGNATOR <br /> OPNG OPENING <br /> m OPP OPPOSITE <br /> • PET PHONE&TELEPHONE DETL TACTILE WARNING TILE <br /> PC PRECAST ( > AI <br /> XXX SCALE: <br /> e PERF PERFORATED N..-./� <br /> PERIM PERIMETER <br /> Ten PGL PROFILE GRADE LEVEL SHEET NUMBER WHERE THE <br /> 3 PLYWD PLYWOOD DETAIL IS SHOWN <br /> o PLAT PLATFORM <br /> • PRV PRESSURE REDUCING VALVE <br /> 2 PT PAINT DETAIL DESIGNATOR <br /> N R RADIUS OR RISER <br /> .,▪i RCP REFLECTED CEILING PLAN X DETAIL CITY OF EVERETT <br /> READ REQUIRED <br /> RO ROUGH OPENING SCALE: REVIEWED FOR PERMI <br /> SECT SECTION DETAIL SHOWN ON THE <br /> SHT SHEET SAME SHEET ONLY <br /> x COMMUNITY TRANSIT Drawing No. <br /> : II IBI GROUP ��� REGISTER Drawnig By 9/30/19 Date SCALE <br /> 801 Second Avenue—Suite 1000 0"" `---....o c i ARC I PERMIT Designed By Nor; SEAWAY TRANSIT CENTER — SHELTER DDITIONS A0. 1 <br /> I I Seattle WA 98104 USA cammUn>Ityt ra nec 9/30/19 NTS <br /> N B tel 206 521 9091 fax 206 521 9095 as GR RY L HILL SET Checked By vent /1 sheet No. <br /> NS <br /> O SNItlA `� STAT F WASHINGTON Approved oveBy 9/30/19 , N/A D A �� A O f 0 Total <br /> ibigroup.com d Pruett Number <br /> �, No. Date Revision By Appr. 20110155.016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.