Laserfiche WebLink
P22 P23 P24 GENERAL & ASSEMBLY NOTES <br /> INTERIOR PARTITION _ ill <br /> TYP. INTERIOR PARTITION FURRING WALL GENERAL NOTES: <br /> ,�\' ' 5/8" TYPE 'X' GWB 1. PROVIDE MOISTURE REISTANT GWB @ KITCHEN WEL WALLS AND I r' �i <br /> 5/8" TYPE 'X' GWB 5/8" TYPE 'X' GWB BATHROOMt,BR �� ; RaER„ INTERIORS. 2 CO N <br /> NR PLYWOOD FRT SHEATHING PER STRUCT NR I NR 2. USE PLYWOOD ADJACENT TO SHEAR WALLS AS NEEDED TO MAINTAIN in o <br /> 9OWTMO Rn,:. R„ F FLUSH WALL FINISHEDZ a o "! <br /> STC MIN 35-39 SOUND BATT INSULATION • n/ u) 0u- <br /> I :/ R-15 BATT INSULATION 3. ALL WALLS SEPARATING LIVING UNITS FROM PUBLIC AREAS SHALL BE LL `C c c <br /> u`"�"Ms,w 'IS <br /> .,�.° STC 50 MINIMUM CL c� N N <br /> �:a sEnrien m . <br /> ASSEMBLY NOTES: ;i < < m CO <br /> 3 5/8" MTL STUD �, 1 . PWALROVIDE FIRE BLOCKING PER IBC 718.2 AT ALL WALLS AND FURRING m o <br /> 2X4 STUD FRAMING PER STRUCT. FURRING -- FIN FLOOR AND BASE PER IFI 2. FIRE RATED ASSEMBLIES ARE BASED ON IBC, UL, ICC, OR US GYPSUM W r w 1 - <br /> �. � � <br /> • <br /> 1. <br /> INTERIOR 2X4 WOOD 2X4 STUD FRAMING PER STRUCT. INTERIOR 2X4 WOOD PARTITION INTERIOR N <br /> PARTITION, DOUBLE SIDED � <br /> SHEAR WALL / M ASSOCIATION (GA) TEST DATA & ARE TO BE CONSTRUCTED IN U ' <br /> / 1 - ACCORDANCE WITH THE REQUIREMENTS OF THE TESTING AGENCIES. <br /> I �� - --- 3 5/8" MTL STUD FRAMING PER STRUCT. REFER TO SPECIFIC TEST REPORTS INCUBATED FOR REQUIRED <br /> � � r <br /> ���1 FIN FLOOR AND BASE PER IFI FIN FLOOR AND BASE PER IFI <br /> � r I ! '�, ' COMPONENTS & ASSEMBLIES. Po I <br /> I� 3. EXTENTS OF ASSEMBLIES ARE SHOWN ON THE PLANS & SECTIONS. to - <br /> 1 4. FIRE RATED ASSEMBLIES FORM A SEPARATION THAT SHALL BE ` ' � <br /> I CONTINUOUS FROM FLOOR TO STRUCTURE ABOVE WITH NO BREAKS AT ®c ARKIeARNEs • <br /> P25 P26 _ R P27 _ COLUMNS, WALL TRANSITIONS, OR OTHER OBSTRUCTIONS. <br /> I►T �� � -' ACOUSTIC SEALANT EACH SIDE �r� ACOUSTIC SEALANT EACH SIDE 5. ALL PENETRATIONS IN FIRE RATED ASSEMBLIES REQUIRED TO HAVE ¢ <br /> INTERIOR PARTITION �� PROTECTED OPENINGS SHALL BE FIRESTOPPED OR PROVIDED WITH • <br /> r� - 5/8" TYPE X' GWB 5/8" TYPE 'X' GWB PARTY WALL 5/8" TYPE 'X' GWB APPROVED SMOKE AND/OR FIRE DAMPERS. • , <br /> PARTY WALL <br /> PLYWOOD- FRT SHEATHING PER STRUCT are KW6. ALL GWB IS TYPE 'X U.N.O. <br /> 1 HR • {' PLYWOOD FRT SHEATHING PER STRUCT 1 HR R-21 BATT INSULATION 1 HR �. iII� 7. SUBSTITUTE TILE BACKER BOARD AT CERAMIC TILE FINISHES. <br /> m� ° I �� _ R 21 BATT INSULATION 8. BLOCKING IS REQUIRED AT THE FOLLOWING LOCATIONS: CASEWORK, <br /> STC 40 44 I SOUND BATT INSULATION STC 55 1" AIR GAP STC 55 <br /> SHELVING & PANELING; ACCESSORIES & EQUIPMENT; DOOR HARDWARE; (` <br /> i <br /> ME <br /> Wirth <br /> i� � �MY B, 1" AIR GAP TOILET PARTITIONS & ACCESSORIES; ACOUSTICAL PANELS; OTHER <br /> GA FILE NO: GA WP 3661 (SIM) ► Et <br /> �t GA FILE NO: GA WP 3370 GA FILE NO: GA WP 3370 (SIM) I'ikraI LOCATIONS WHERE REQUIRED PER MANUFACTURER'S <br /> UL DESIGN U305 DESIGN U305 (SIM) RECOMMENDATIONS OR INDUSTRY STANDARDS. , <br /> ACOUSTIC SEALANT EACH UL `� / ACOUSTIC SEALANT EACH 9. ALL WALL AND FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS <br /> ►' ` • <br /> ` <br /> INTERIOR 2X6 WOOD . { i1 2X6 STUD FRAMING PER STRUCT. I� ® SIDE OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA WITHIN et <br /> PARTIT2X6 STUD FRAMING PER STRUCT. r <br /> SHEAR IWALLINGLE SIDED 410 / ®i, li' . <br /> , EXCEEDTHE 50.CTURE SHALL HAVE STC AND IIC RATINGS TO MEET OR <br /> S�/ � r �� 2X6 STUD FRAMING PER STRUCT. LLI <br /> k Irai ' / 10. WHERE CLADDING/ FURRING ATTACHMENT WILL NOT BE INTO aI iii r'� SCHEDULED FRAMING, ADDITIONAL FRAMING AND/OR BLOCKING- FIN FLOOR AND BASE PER IFI FIN FLOOR AND BASE PER IFI � I r Wl.I A��I ; FIN FLOOR AND BASE PER IFI SHOULD BE PROVIDED FOR ATTACHMENT, AS REQUIRED BY THE <br /> ��� or p►���jif���� MANUFACTURER. W r- <br /> 11.WHERE CABINETS ARE MOUNTED TO CORRIDOR WALLS WITH RESILIENT W < O <br /> P28 P29 P30 I CHANNEL ON THE INSIDE USE GUIDANCE PROVIDED BY USG SA-923 FOR W CV <br /> �_� MOUNTING CABINETS ON RESILIENT CHANNELS. W <br /> • ---- ACOUSTIC SEALANT EACH SIDE - ,- C. ' <br /> W W Q <br /> • <br /> PARTY WALL A - 5/8" TYPE 'X' GWB TYP. INTERIOR PARTITION INTERIOR PARTITION .t`� Lw <br /> I 4 _ -- 5/8" TYPE 'X' GWB 5/8" TYPE 'X' GWB - <br /> • <br /> PLYWOOD FRT SHEATHING PER STRUCT R�R,R� W <br /> 1-HR <br /> I R-21 BATT INSULATION NR I, E1 HR • <br /> 0 W <br /> srcann"s i / sir I <br /> STC 58 SOUND BATT INSULATION <br /> STC 55 • r 1' AIR GAP �— SOUND BATT INSULATION STC 58 \. O <br /> GA FILENO: GA WP 3370 (SIM) Af 'r �~GA FILE NO: GA WP 3661 (SIM) __ L.L `- <br /> `! O W <br /> UL DESIGN U305 (SIM) — ACOUSTIC SEALANT EACH SIDE r` <br /> co.. n�� cw�wrs �' Ic�u,cxrs • �- r" C <br /> INTERIOR 2X6 WOOD PARTITION INTERIOR 2X6 WOOD PARTITION <br /> AI <br /> i 2X6 STUD FRAMING PER 2X6 STUD FRAMING PER STRUCT. 0 <br /> ' S �� . 2X6 STUD FRAMING PER STRUCT. � . / STRUCT. / <br /> � � K <br /> �o. - �JN <br /> '� FIN FLOOR AND BASE PER IFI / _,: / FIN FLOOR AND BASE PER IFI . FIN FLOOR AND BASE PER IFI <br /> re <br /> ►� ��►�� bt:11/1.111/1,,', <br /> iP31 - P32 - P33I -<: : III <br /> INTERIOR PARTITION / INTERIOR PARTITION 'rINTERIOR PARTITION(2) LAYERS 5/8" TYPE 'X' GWB EA SIDE - (2) LAYERS 5/8" TYPE 'X' GWB EA SIDE' : � 5/8" TYPE 'X' GWBE <br /> 2 HR :\ % �2 HR — PLYWOOD FRT SHEATHING PER STRUCT NR '191, 1 <br /> PLYWOOD FRT SHEATHING PER STRUCT <br /> w .0 STC STC 40 44 <br /> STC 40-44 SOUND BATT INSULATIONSOUND BATT INSULATION ' • <br /> •40�4 e- SOUND BATT INSULATION <br /> M^1'CIkiLY l6l I ru �` , I I AStELBLYt6!"O ' �� ll I <br /> GA FILE NO: GA WP 4135 (SIM) A` GA FILE NO: GA WP 4135 (SIM) • <br /> -.111119 <br /> INTERIOR 2X6 WOOD PARTITION 2X6 STUD FRAMING PER STRUCT. INTERIOR 2X6 WOOD 2X6 STUD FRAMING PER STRUCT. INTERIOR 2X6 WOODNiall <br /> 2X6 STUD FRAMING PER STRUCT. <br /> PARTITION, SINGLE SIDED �111000-� PARTITION, DOUBLE SIDED • <br /> rao_kail SHEAR WALL ;M , SHEAR WALL Ir.; <br /> �pall <br /> 1 lira, FIN FLOOR AND BASE PER IFI ian / FIN FLOOR AND BASE PER IFI FIN FLOOR AND BASE PER IFI <br /> P34 i __P35 ___ <br /> P36 <br /> INTERIOR PARTITION ___ <br /> -1 <- <br /> -��A INTERIOR PARTITION1 . <br /> 5/8" TYPE 'X' GWB - FURRING WALL <br /> —.. _ - .. - 5/8" TYPE 'X' GWB <br /> � 'r _ -- 5/8" TYPE 'X' GWB i <br /> 6611 . <br /> NR IL PLYWOOD FRT SHEATHING PER STRUCT NR NR \ \REGISTEREDT <br /> STC 40114 1 SKR\M1B R B° <br /> y SOUND BATT INSULATION �, r �..•�_ <br /> wstaBMruanxc (i. <br /> A4sB1"Lr USING <br /> W SCOTt CIARK <br /> n VS__TATE OF WASHING^TON <br /> INTERIOR 2X6 WOOD 2X6 STUD FRAMING PER STRUCT. " INTERIOR 2X6 WOOD PARTITION 2X6 STUD FRAMING PER STRUCT. INTERIOR 2X4 WOOD FURRING FIN FLOOR AND BASE PER IFI <br /> PARTITION, SINGLE SIDED / DATE: 01/25/21 <br /> SHEAR WALL / <br /> Ii _�\ 1 <br /> JOB NO. 19-48 <br /> 12X4 STUD FRAMING PER STRUCT. PERMIT N0.62006-044 <br /> y FIN FLOOR AND BASE PER IFI <br /> — FIN FLOOR AND BASE PER IFI <br /> B2009-016 <br /> rl =c REVISIONS: <br /> DATE DESCRIPTION <br /> P37 P38 P39 1 01/19/21 PERMIT REV 1 <br /> firwi <br /> TYP. INTERIOR PARTITION INTERIOR PARTITION / 2X6 STUD FRAMING PER STRUCT. INTERIOR PARTITION � �` �- - 2X6 STUD FRAMING PER STRUCT. <br /> ' SOUND BATT INSULATION INSULATION <br /> SOUND BATT SU „ <br /> (2) LAYERS 5/8" TYPE 'X' GWB EA SIDE <br /> 1 HR • ` (2) LAYERS 5/8" TYPE 'X' GWB EA SIDE 2 HR 4: • <br /> _ _ 5/8" TYPE 'X' GWB EA SIDE 2 HR <br /> STC MIN 35-39 STC 55 • 1/2" AIR GAP <br /> A4SEnBLY 4ATM5 ��.. STC 55. �:- <br /> GA FILE NO: GA WP 3661 (SIM) �� <br /> I GA FILE NO: GAWP 3812 (SIM) EGA FILE NO: GA WP 3812 (SIM) . 1 ` � s:: SOUND BATT INSULATION ISSUE • <br /> : <br /> _ Mil <br /> FEE:::TRE <br /> INTERIOR 2X4 WOOD PARTITION FIN FLOOR AND BASE PER IFI INTERIOR 2X6 WOOD PARTITION �!6-1/2 AIR GAPINTERIOR 2X6 WOOD PARTITION I - FIN FLOOR AND BASE PER IFI <br /> ` } d , <br /> 2X4 STUD FRAMING PER STRUCT. - FIN FLOOR AND BASE PER IFI ���� � <br /> PHASE II 08/31/20 <br /> P / , 2X4 STUD FRAMING PER STRUCT. GMP 09/30/20 <br /> 2X4 STUD FRAMING PER STRUCT. PERREV1 iiiiiiiMMI <br /> j. __7\1K .1 ] <br /> �ng ` IFC SET 01/25/21 • <br /> A I " PERMIT REV 2 02/19/21 <br /> IFC SET 02/19/21 <br /> P40 P41 P42 PERMIT REV 3 05/26/21 <br /> FURRING WALL FURRING WALL FURRING WALL I <br /> — INTERIOR <br /> NR N <br /> R R`NR i WALL TYPES <br /> s<anrun -- - - -- - --- (1) LAYERS 5/8" TYPE 'X' GWB - - ---- (1) LAYERS 5/8" TYPE 'X' GWB I <br /> "`" "° p iN0 � (1) LAYERS 5/8" TYPE 'X' GWB <br /> ASSEMBLY USING <br /> f- __\/ CITY OF EVERETT <br /> EVIEWED FOR PERMIT <br /> COIb!"" -- --- 1 3/8" STEEL CH STUD °`B'tJ"° - -- - --- 2" STEEL CH STUD <br /> INTERIOR HAT CHANNEL INTERIOR HAT CHANNELINTERIOR HAT CHANNEL - 1/2" STEEL CH STUD . SHEET NO: <br /> FURRING FURRING 11-----7-- <br /> FURRING <br /> -- ---- FIN FLOOR AND BASE PER IFI <br /> FIN FLOOR AND BASE PER IFI 1111 :� FIN FLOOR AND BASE PER IFI <br /> A8 . 10 <br />