P43 P44 P45 GENERAL & ASSEMBLY NOTES • <br /> ACOUSTIC SEALANT EACH SIDEco <br /> '_' / <br /> PARTY WALL .' ® INTERIOR PARTITION .( V GENERAL NOTES: <br /> i. 3 HR PARTITION <br /> (2) LAYERS 5/8" TYPE 'X' GWB EA SIDE (3) LAYERS 5/8" TYPE 'X' GWB EA SIDE 1. PROVIDE MOISTURE REISTANT GWB @ KITCHEN WEL WALLS AND I 1 ' r' �i <br /> �� (2) LAYERS 5/8" TYPE 'X' GWB EA SIDE.^- BATHROOM INTERIORS. ` W 2 °n° <br /> 1'RC RAMS <br /> �L <br /> 1 HR �- �� � 2 HR _ PLYWOOD FRT SHEATHING PER STRUCT 3 HR I ' 2. USE PLYWOOD ADJACENT TO SHEAR WALLS AS NEEDED TO MAINTAIN CO °' o <br /> $cSTC 55 �� '� 1 AIR GAP STC 40-44 SOUND BATT INSULATION STC 49 SOUND BATT INSULATION 3 ED m <br /> MONO FLUSH WALL FINISH <br /> ALL WALLS SEPARATING LIVING UNITS FROM PUBLIC AREAS SHALL BE ^ ' C 0 <br /> — R-19 BATT INSULATION A. ' r w rc,.a-.nv • <br /> GA FILE NO: GAWP 3370 ell GA FILE NO: GAWP 4135 (SIM) V i GA FILE NO. WP 2750 `�q STC 50 MINIMUM <br /> V <br /> UL DESIGN U305 ASSEMBLY NOTES: < < 4°) 3 m <br /> 1. PROVIDE FIRE BLOCKING PER IBC 718.2 AT ALL WALLS AND FURRING °' N- <br /> CIX,.GNT9 <br /> FIRE RETARDANT FRAMING AT IL <br /> ACOUSTIC SEALANT EACH SIDE INTERIOR 2X8 WOOD INTERIOR 6" MTL STUD WALLS. o <br /> 2X8 STUD FRAMING PER STRUCT. 6" MTL STUD PER STRUCTURAL f6 <br /> TYPE 1 .1 CONSTRUCTION PER PARTITION, SINGLE SIDED PARTITION 2. FIRE RATED ASSEMBLIES ARE BASED ON IBC, UL, ICC, OR US GYPSUM COuJ in F- <br /> IBC 603.1.1 ® 6" MTL STUD FRAMING PER STRUCT. SHEAR WALL IS404 U <br /> rai <br /> IHAI-41 <br /> ASSOCIATION (GA) TEST DATA & ARE TO BE CONSTRUCTED IN- ACCORDANCE WITH THE REQUIREMENTS OF THE TESTING AGENCIES.FIN FLOOR AND BASE PER IFIFIN FLOOR AND BASE PER IFIREFER TO SPECIFIC TEST REPORTS INCUBATED FOR REQUIRED <br /> rr...,,,,_. <br /> / FIN FLOOR AND BASE PER IFICOMPONENTS & ASSEMBLIES. <br /> I` 3. EXTENTS OF ASSEMBLIES ARE SHOWN ON THE PLANS & SECTIONS. i A.'t •. 4 $ „h ,: f <br /> P46 P47 p48 4. FIRE RATED ASSEMBLIES FORM A SEPARATION THAT SHALL BE r <br /> CONTINUOUS FROM FLOOR TO STRUCTURE ABOVE WITH NO BREAKS AT CG ARKi BARNES <br /> UMNS, WALL <br /> NS, OR OTHER OBSTRUCTIONS. <br /> _~ = ACOUSTIC SEALANT EACH SIDE i ; 5. ALL LPENETRATIONS IN FIRE ORATED ASSEMBLIES REQUIRED TO HAVE <br /> TYP. CORRIDOR WALL 'I f TYP. INTERIOR PARTITION ACOUSTIC SEALANT EACH SIDE 7�p_ INTERIOR PARTITION PROTECTED OPENINGS SHALL BE FIRESTOPPED OR PROVIDED WITH <br /> PLYWOOD FRT SHEATHING PER STRUCT 5/8" TYPE 'X' GWB APPROVED SMOKE AND/OR FIRE DAMPERS. <br /> (2) LAYERS 5/8" TYPE GWB EA SIDE " R, 2X8 STUD FRAMING PER STRUCT. — 6. ALL GWB IS TYPE 'X' U.N.O. <br /> 2HR <br /> i 1 HR ' Rom,"�NR 7. SUBSTITUTE TILE BACKER BOARD AT CERAMIC TILE FINISHES. • <br /> 5!8" TYPE 'X' GWB EA SIDE — 8. BLOCKING IS REQUIRED AT THE FOLLOWING LOCATIONS: CASEWORK, <br /> 9TC MTNC - - STC Writ' <br /> STC 49 STC 55 �ISTC 45 • - SOUND BATT INSULATION SHELVING & PANELING; ACCESSORIES & EQUIPMENT; DOOR HARDWARE; <br /> '� ti•r :v s M, — SOUND BATT INSULATION w. „R TOILET PARTITIONS & ACCESSORIES; ACOUSTICAL PANELS; OTHER <br /> GA FILE NO: GA WP 3812 (SIM) r- 2x4 STUD & 2x6 MTL STUD GA FILE NO: GA WP 3661 (SIM) / LOCATIONS WHERE REQUIRED PER MANUFACTURER'S <br /> 11111114. <br /> g STAGGERED WITH 2x8 STUD <br /> A 8" i 8;- , RECOMMENDATIONS OR INDUSTRY STANDARDS. <br /> « "« D- Li- BOTTOM PLATE cow Ts l <br /> ..;:Ns Y 1,4l <br /> 9. ALL WALL AND FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS <br /> INTERIOR 2X8 WOOD PARTITION INTERIOR 8" MTL STUD 8" MTL STUD PER STRUCTURAL OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA WITHIN12 <br /> PARTITION THE STRUCTURE SHALL HAVE STC AND IIC RATINGS TO MEET OR I <br /> . EXCEED 50. W <br /> - ACOUSTIC SEALANT EACH .0.a._ All / <br /> • 10. WHERE CLADDING/ FURRING ATTACHMENT WILL NOT BE INTO <br /> — ACOUSTIC SEALANT EACH SIDEAO W <br /> SIDE • <br /> SCHEDULED FRAMING, ADDITIONAL FRAMING AND/OR BLOCKING <br /> FIN FLOOR AND BASE PER IFI FIN FLOOR AND BASE PER IFI likili 1 <br /> j FIN FLOOR AND BASE PER IFI SHOULD BE PROVIDED FOR ATTACHMENT, AS REQUIRED BY THE <br /> • <br /> MANUFACTURER. > r <br /> 11.WHERE CABINETS ARE MOUNTED TO CORRIDOR WALLS WITH RESILIENT W Q O <br /> CHANNEL ON THE INSIDE USE GUIDANCE PROVIDED BY USG SA-923 FOR N <br /> MOUNTING CABINETS ON RESILIENT CHANNELS. J co <br /> W JQ <br /> W <br /> i.fC.) UI- <br /> O ° w <br /> W r > <br /> 0 <br /> O (NI <br /> NI <br /> I <br /> 1 <br /> k <br /> • <br /> a, <br /> I <br /> 4 <br /> I <br /> • <br /> g <br /> 6611 <br /> - - } 1 REGISTERED <br /> . �/ ARCHITECT <br /> u.'. %C0r CAA . <br /> a W SCOTT CLANK <br /> a, STATE OF WASHINGTON <br /> • <br /> t <br /> • <br /> DATE: 01/25/21 . <br /> JOB NO. 19-48 <br /> $ PERMIT NO.B2006-044 <br /> B2009-016 <br /> REVISIONS: <br /> r Alk <br /> I. . DATE DESCRIPTION • <br /> 1 01/19/21 PERMIT REV I <br /> 2 02/19/21 PERMIT REV 2 <br /> • <br /> - O <br /> I <br /> ISSUE <br /> SHORING/EX 05/08/20 <br /> PHASE I 06/22/20 <br /> #. BID PROG SET07/13/20 <br /> - - PHASE II 08/31/20 ' <br /> REVIEWEDPt i <br /> GMP <br /> FO 09/30/20 <br /> 9. <br /> I <br /> PERMIT REV 1 01/19/21 • <br /> IFC SET 01/25/21 <br /> PERMIT REV 2 02/19/21 <br /> IFC SET 02/19/21 <br /> PERMIT REV 3 05/26/21 <br /> • INTERIOR <br /> WALL TYPES <br /> CITY OF EVERETT <br /> R PERM <br /> I <br /> SHEET NO: <br /> L A8 . 11 <br /> - -- _ -- <br />