My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
840 N BROADWAY B 2021-07-12
>
Address Records
>
N BROADWAY
>
840
>
840 N BROADWAY B 2021-07-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2021 9:25:45 AM
Creation date
7/12/2021 9:24:36 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
840
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 4 <br /> C <br /> Ms. Clover Schuler <br /> Magellan Architects <br /> Plan Check Number: B1810-012, First Review <br /> November 7, 2018 <br /> C8Means o ress illumination shall be provided in the room and in the hallways leading :: <br /> to the exits. " C Section 1008.3.1. The lighting shall require an emergency power ,,, <br /> supply per IBC Sectio 008.3.4. <br /> MA response: Thi s been addressed on sheet A0.4 <br /> 0 The exterior landings for exit doors serving the room shall be provided with emergency <br /> x <br /> lighting. The lighting shall require an emergency power supply=per IBC Section <br /> 1008.3.4. See IBC Sections 1008.3.2 Item 5 and 1010.1.6. <br /> MA response: This has been addressed on sheet A0.4 <br /> `-k CThe occupant load shall be posted near the main exit per IBC Section 1004.3. <br /> MA response: This has been addressed on sheet A0.4 <br /> __., g The doors shall be provided with panic hardware per IBC Section 1010.1.10. <br /> MA response: This has been addressed on sheet A7.1 <br /> 9C. Continuing with the prey us-coi ment, all doors in the exit access shall similarly be <br /> provided with panic hardware. See ' n 202 for the definition of the exit access. <br /> MA response: This has been address heet A7.1 <br /> 5. The egress for the 2nd Story office area shown on Sheet A0.4 is affected by the alterations <br /> to the waiting and counter areas. The office area has an occupant load of over 100 and <br /> requires two exits per IBC Section 1006.2.1 and Table 1006.2.1. See also IEBC Section <br /> 805.4.1.1. The following comments shall be addressed: <br /> a�. Exit si s shall be provided at each door. In addition, exit signs shall be provided along <br /> the exit acc '.e., hallways and stairs), including intervening doors. Direction arrows <br /> shall be provided a required., Additional signs shall be provided where the path of <br /> egress travel is not visib e.g., room corners, etc.). See IBC Section 1013.1. <br /> MA response: This been addressed on sheet A0.4 <br /> 0 Means of egress illumination shall be provided in the room, stairways, and hallways <br /> leading to the exits. See IBC Section 1008.3.1. The lighting shall require an emergency <br /> power supply per IBC Section 1008.3.4. <br /> MA response: This has been addressed on sheet A0.4 <br /> CO The exterior landings for exit doors serving the room shall be provided with emergency <br /> lighting. The lighting shall require an emergency power supply per IBC Section <br /> 1008.3.4. See IBC Sections 1008.3.2 Item 5 and 1010.1.6. <br /> MA response: This has been addressed on sheet A0.4 <br /> OThe doors shall be provided with panic hardware per IBC Section 1010.1.10. <br /> MA response: This has been addressed on sheet A7.1 <br /> 6 Continuing with the previous comment, all doors in the exit access shall similarly be . <br /> provided with panic hardware. See Section 202 for the definition of the exit access. <br /> MA response: This has been addressed on sheet A7.1 (]3 <br /> C 3200 Cedar Street 425.257.8800 0 everettpw@everettwa.gov <br /> �% <br /> Everett,WA 98201 425.257.8882 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.