rit- : " SOUND STRUCTURAL SOLIINS <br /> ENGINEERSVile 0. <br /> 23.The east retaining wall on the north end of the building is an existing cantilevered <br /> retaining wall and will be connected to a cantilevered diaphragm at the main floor <br /> level. The proposed cantilevered diaphragm will not be rigid enough to restrain the <br /> existing cantilevered retaining wall at the top of the concrete. Thus, the lateral <br /> earth pressures and associated seismic surcharge will be resisted solely by the <br /> existing wall and the proposed diaphragm will not receive any earth pressures. <br /> 24.Please see detail FL1/S-2 which includes a redesigned steel ledger capable of <br /> resisting both out-of-plane and in-plane shear loading along with gravity load. <br /> Please see pages 97-109 of the revised calculation package for the analysis of the <br /> new floor ledger connection. <br /> 25.Detail FL2/S-2 which includes a redesigned steel ledger capable of resisting both <br /> out-of-plane and in-plane shear loading along with gravity load. <br /> 26.The seismic overstrength factor need not be applied to the holdown anchorage as <br /> the holdown capacity is approximately 25% less than the anchorage for both the <br /> cast-in-place and post-installed situations. The anchorage need only be designed <br /> for the maximum tension that can be transmitted to the anchors by a non-yielding <br /> attachment per ACI 318-14 Section 17.2.3.4.3 (c). <br /> 27.Holdowns have been added to wall line 2. The loading on wall lines 4 and D are light <br /> and have been checked as perforated shear walls on page 26 of the revised <br /> calculation package — no holdowns are required at either of these wall lines. <br /> 28.No holdowns are required at the main floor for wall line 4 per the perforated shear <br /> wall analysis on page 26 of the revised calculation package. <br /> 29.Please see detail FL1/S-2 which includes a redesigned steel ledger capable of <br /> resisting the added vertical loads including the seismic overstrength factor from the <br /> upgraded shear walls above. This calculation also includes the combined axial and <br /> flexural check as the new ledger is also being used to bolster the existing concrete <br /> collector. <br /> 30.Please see detail FL1/S-2 which includes a redesigned steel ledger capable of <br /> resisting the added drag forces. This calculation also includes the combined axial <br /> and flexural check from the gravity/overturning loads from above. <br /> If you have any questions, require additional information, or believe we have <br /> misinterpreted your requests, please call us at 425-778-1023, and we'd be happy to <br /> discuss them. <br /> 24113 56th Ave W - Mountlake Terrace,WA 98043 - Ph:425-778-1023 - Fax: 206-260-7490 )+ <br />