Laserfiche WebLink
WRB SIDING ° SIDING SIDING < - �[t SIDING I <br /> WRB WRB n r, 1 J_�___ NEW DRYVIT FINISH COAT OVER FACE <br /> �I — I �.II WRB �1NEW <br /> FURRING I ! t I\ ' , FURRING FURRING . FURRING ' BLEND WITHEXISTING FINISH TO <br /> BACKER ROD &SEALANT I ? I ' <br /> NEW 5/4X4 CEDAR- I < , \ I BACKER ROD &SEALANT BACKER ROD &SEALANT I i / BACKER ROD &SEALANT I <br /> EXISTING DRYVIT FINISH COAT I S O m I t h <br /> PAINT TO MATCH DRYVIT I NEW 5/4X4 CEDAR- SEAL NEW WRB TO A I / EiE1 \II2\/ K <br /> R- 1II $;: <br /> RYVIFORCINGH DRI EDDEXISTING TOSE COC 0 X <br /> ` ITHNSUL BOARD -.IrR4" x 1/8" Y FOR I\ \ <br /> j DR COMPATIBLE \ I3MIN. archite? s <br /> AIBLEICOATSH DRAINED 2-STAGE JOINT ` -STAGE JOINT <br /> I <br /> (' 'II = REPAIR EXISTING II f IST. BASE COAT BY <br /> REPAIR EXISTING ' I <br /> ))'X, ;I a I �. DRYVIT PER 4/A8.02 m I I DRYVIT PER 4/A8.02 \_ )\---=- HOT KNIFE METHOD I 1928 43rd Ave E., Ste A <br /> } I :"; ::� : ` \ -J \ `� r I Seattle , WA 981 1 2 <br /> J _ 1 u ` X�s } W , - :. ;` . ›- : I = I ( 206 ) 453 . 4053 <br /> m0 � " •••�• - .. l \ \\\ `�\ \ -J U) B- - - -� A J - � shoesmithcox. com <br /> I <br /> W2 Lil IlliKir <br /> w < - ___ 2( -- 4'/,'/- f <br /> QZ �u) Z ZLL T / u) z % \ \ % ------- <br /> C7 >- c'Q E- W Qz K)/( <br /> Z Z X Z L}i.a�' 3" COMPATIBLE SEALANT <br /> w \ W W f WITH CLOSED CELL <br /> X { (A \ , / \ U) /V\ NEW DRYVIT DETAIL MESH BACKER ROD <br /> _}\,._ EMBEDDED IN NEW DRYVIT <br /> \ I i ' G REAR SEAL <br /> \ \ � . W - i BASE COAT BEHIND EXISTING <br /> SEAL NEW WRB TO I !' _ _.__. IL BASE COAT <br /> EXISTING WRB WITH <br /> SAM-OVERLAP 4" <br /> _i_ <br /> 1 <br /> 20 INTERSECTION OF NEW WALL AT EXIST. 16 INTERSECTION OF NEW WALL AT EXIST. A INTERSECTION OF NEW WALL AT EXIST. INTERSECTION OF NEW WALL AT EXIST. DRYVIT REPAIR AT NEW CONSTRUCTION <br /> 3" = 1'-0" 3"= 1'-0" 3"= 1'-0" 8 4 <br /> 3' = 1'-0" 6" = 1' 0" <br /> 0.2 <br /> 18 A " SIDING SYSTEM PER _ <br /> LAP W.R.B. OVER FLASHING 8 02 •.'. WALL ASSEMBLY SIDING ST-1 PER !Will �- <br /> .. : • <br /> .. NEW DRYVIT FINISH COAT OVER FACE ELEVATION i , ` 'i' FILL STUD CAVITY <br /> &TAPE (W.R.B. NOT SHOWN :>; I ';, OF PATCH - FEATHER NEW FINISH TO / (1 ABOVE SCUPPER WITH <br /> FOR CLARITY) INSTALL SELF-ADHERING FLEX. ' <br /> R� : "•r- .�-�•-� • - • :•�,-. .•..;,�:�I.�•`' � BLEND WITH EXISTING I M I AIR IMPERMEABLE <br /> FLASHING OVER BRACKET FLANGES. 1 •} •' <br /> :r-!' ,. ``` EXISTING DRYVIT FINISH COAT 6"WIDE OVERFLOW CLOSED CELL SPRAY <br /> JAMBS FIRST, THEN HEAD. " ✓ 1/2" JOINT W/ SEALANT <br /> 'v I INSULATION A bethany <br /> Q����S ' • •- •• EXISTING DRYVIT REINFORCING <br /> :, a, BACKER ROD ALL MESH EMBEDDED IN EXISTING NEW DRYVIT FINISH COAT <br /> ��-S00 GALV. SHEET MTL. VENT BASE, ::::3: ' ' r <br /> JP�� SOLDER ALL SEAMS ;+. • .,�.:.. :.:.1':..: 4.:. .;4. ...,: ,* AROUND AROUND VENT BASE DRYVIT BASE COAT NEW DRYVIT REINFORCING --�..,, :.-- - <br /> • • Ir— �-- _ skilled nursing <br /> I`` .1". .. '.::, : BOX MESH EMBEDDED IN NEW <br /> D. �J .y. _,,.' :; ' .,.. .: : ' EXISTING INSULATION BOARD <br /> 1!°Ili <br /> ' ,•" DRYVIT BASE COAT(BACK <br /> 1#,_;; <br /> ": : `'': `.•. �.n . : .. , L ..:.,, 1/8"CAVITYFOR 24 WIDE SCUPPER 24 x 40"SUMP, <br /> •. CREATE 3"x 3/4" MIN <br /> �• ���•��°'- �•�' • % :: • -- ` WRAP INSULATION BOARD additions <br /> • !I ' ' I. : I:::':'.< .: PREFINISHED VENT NEW BASE COAT&MESH / / SIM TO 1/A8.02 <br /> 4j000 r, <br /> • <br /> `� " :� :: �` BEHIND EXIST. BASE COAT BY (TYP.) I / <br /> ► I `.: `.: ' . °.. . . I. SHROUD, ATTACH W/ HOT KNIFE METHOD <br /> '" ` •''' I NEW INSULATION BOARD I <br /> , ..'.. ' ' . • . `. . ST. STL. SCREWS DRYVIT A TO DECK AT SCUPPER - <br /> % , I .. I.. .:. ,',. ADHESIVE l. - - - - - N 2235 Lake Heights Drive <br /> INSTALL BACKDRAFT DAMPER I: .,.::::: • I SEE ROOF PLAN <br /> 4 I W/SEALANT ALL AROUND : :. `:I • "G:,. . I �I I { I . - - -Ira& <br /> , � 1---_.-ssi=pilarrwp.�_ SOLDERED FOLDED SEAM I / / N <br /> I I "� "' lk I I ,�,'-' METAL FLASHING, EXTENDl/ Everett WA 98208 <br /> 1111? <br /> .1� � II �� III � >.:..II ` I � 6 AT SCUPPER )n' I :. h . , :: I �� % \ \ \\\ SHINGLE ROOF PER ����.>,�-1 i . \ <br /> rn w �.: :.I ,... OF <br /> ROOF PLAN , �. <br /> w m I: ~ .- �� 1 <br /> CUT HOLE IN BASE SHEET TO MATCH 18 B 3" COMPATIBLE SEALANT .���' <br /> j z VENT PIPE SEAL ALL AROUND PIPE \A8.02 , . :}.,: .- `I< ' :,I .: ` / / WITH CLOSED CELL -.+".'`"�� <br /> IN ` :.I. _ o NEW DRYVIT DETAIL MESH BACKER ROD ����"� :-:\\\1 <br /> ST-1 �. <br /> I '� <br /> SLIP BASE SHEET OF W.R.B. UNDER EMBEDDED IN NEW DRYVIT SIDING PANEL, ST-1 <br /> BOTTOM FLANGE PRIOR TO :I:::: �` BASE COAT EHIND EXISTING REAR SEAL <br /> = OP <br /> B <br /> SET FLANGE IN CONT. BED OF V FLASHING I '� .I'.. o BASE COAT FLAS PT-1 <br /> „r/ SEALANT(AIR BARRIER) WOOD, -� <br /> O , ST-6 <br /> STEP 1 �� �'��i:���'�.�:,:�-. : '•.'.::..�:..�=�.-�-'•.::: .,:: : :•: ...:.,.. <br /> NOTE: SEE DETAIL 10 THIS SHEET ::`'::'' : / o SIDING ST-1,PER <br /> T +� <br /> VENT SHROUD FOR TYPICAL VENT SHROUD SIZES. STEP 2 •:'.' STEP.�?.+ : ;`'•: JOINT NEW DRYVIT TO EXISTING ELEVATIONBethany <br /> 19 _ 7 - 3 <br /> MECHANICAL WELL SCUPPER <br /> 1 1/2"= 1' o" '. 6„ = 1'-0",. :.:. ::". /2"= 1' 0" of the Northwest <br /> Yt fl West <br /> 11 - <br /> EXHAUST DUCT(S) II NO. DATE REVISION <br /> FLEX. FLASHING LAP OVER NOTE: CEMENT PANEL <br /> FLANGE TYP. SIDING SHOWN -LAP <br /> SIDING SIM. 2" A OVE) SIM.VENTED PARAPET CAP I\ - - -CRICKET <br /> : <br /> CONTINUOUS BED OF _TO 2/A8.01 f <br /> _ _ A°3292019 <br /> CITY RESPONSE#1 <br /> SEALANT BETWEEN \ CONTINUOUS BEAD CF 1 -O 2" 2 2'-0" <br /> 2 I <br /> _ <br /> 4" FLANGE AT SHROUD BASEA SEALANT BETWEEN - _ 05.30.2019 CITY RESPONSE#2 <br /> SHROUD AND WRB TYP. SHROUD AND WRB \ _ — -- _ <br /> 5 — -� \ —I �-� �- �� PROVIDE (3) 1-1/2"x5" _ _ <br /> SEALANT& BACKER S _ SLOTS IN BLOCKING FOR `�' <br /> \� / ROD, TYP. <br /> o LEI o I- J i — I ICI VENTILATION PER - f� <br /> \ - J L� JL - J 10/A8.01 <br /> N Illoo , 'iN <br /> \ ,4o SINGLE VENT ELEV TRIPLE VENT ELEV METAL FLASHING, EXTEND <br /> PLASTIC LOUVERED �I © 6"AT SCUPPER <br /> I :'''' <br /> ' I i 5" BACKDRAFT DAMPER. _, <br /> SHINGLE ROOF PER , w�`�'a \:,...,\J\(--, <br /> I I y ( I / SEAL ALL SIDES(TYP.) \ , \ 2„ 1'-6" <br /> �j ,,� 2' ROOF PLAN w <br /> I I � II I N 1 <br /> RI � 1:416- <br /> AN.�,� <br /> EHAUST DUCT _ METAL CAP, �►�' � ' , <br /> I I I I o cf\ SEALANT& 2 1'-6" 2 \ l- = Fr--1 PAINT ���� ST-1 •�! -, - <br /> I 6 r BACKER ROD I I �TO PARAPET - \ ' SIDING PANEL, ST-1 '„`� `� <br /> I I I — GALV. SHROUD BASE- \ (-\ <br /> 4--- --= +11'-9 1/2" r d• ROOFING PROJECT MANAGER <br /> \ � L — JL — / �`� MEMBRANE FLAS •� , PT-1 JS <br /> I I SLOPE SOLDER ALL SEAMS / // <br /> I— I - `� f/.�/f'. WRAP OVER WOOD, ST-6J PROJECT ARCHITECT <br /> I TO EXTDUCT I I I I I GALV. PRE-FINISHED N (3)ST. STL. o LEI I � I L J_) I I <br /> ' SHROUD, COLOR TO SCREWS EA. SIDE L — J L--- J 4 r,,, ' //` e CURB JS <br /> @ 4"O.C, _ �', SIDING ST-1,PER PROJECT TEAM MEMBERS <br /> `�I \ d MATCH SIDING TYP. 1" 8"OR 16" OR 24"OR 32" \ \ y r ELEVATION <br /> I \ DOUBLE VENT �,/ OMECHTS <br /> SIZE PER NUMBER OF VENTS ELEV QUAD VENT ELEV // WELL FRAMING FOR VENTING CHECK <br /> \ HEM ALL EDGES,TYP. -SEE VENTING DIAGRAM <br /> /,//.' �/` 1 1/2" = 1'-0" OF <br /> � "-MIN. DIM. TO ALLOW FOR MIN. 3'-0"CLEAR TO 10"OR 18" OR 26"OR 34" f/// 0 \IN <br /> \ SEALANT INSTALLATION OPERABLE WINDOWS OR ,� / /' /// Qti O <br /> -_ // " QARCHITECTSEAL <br /> DOORS SIZE PER NUMBER OF VENTS- / �PVENT SHROUD A - SECTION v B- PLAN SEE VENTING DIAGRAM VENT SHROUD3" = 1' 0" '1 0 <br /> 6X6 POST REGISTERED <br /> SEE STRUCTURAL FOR POST 7534 <br /> 2.0 j/'////s '� FILL STUD CAVITY SEALANT BEAD @ ARCHITECT <br /> CONNECTIONS TOP&BOT. f_�/ /20 <br /> -/ ABOVE SCUPPER& \ I \__ <br /> FLANGE '` 1 <br /> l -.,--* OVERFLOW WITH <br /> SLOPE CMU SILL 2:12 \ _ / - -\ AIR IMPERMEABLE JOHN A. SHOESMITH <br /> • <br /> 2X6X16 CMU SILL CUT TO FIT 6"WIDE OVERFLOW <br /> &SLOPE PER 17/A8.02 24X24 DRAIN �--�� I d CLOSED CELL STATE OF WASHINGTON <br /> SUMP A <br /> SPRAY INSULATION <br /> f....... f / - 2"CANT STRIP I \ <br /> / 4 , / 3 COURSES 4X8X16 SPLIT FACE 6X6 POSTS @SUMP ( •c .� <br /> CMU -RUNNING BOND, TYP. PERIMETER. I <br /> - LINE OF BEAM ABOVE + OUTLINE OF 24 X 24 SUMP 2'-0„ <br /> / / o SCUPPER /,'' N / 6" / FLANGE. - — C° SOLDERED FOLDED <br /> I <br /> r '1 y " L I I r `�' �� — — -- $TODECKATSCUPPER SEAM <br /> >___\,. _" Af - - — 1 SEE ROOF PLAN TITLE <br /> L ,�s`�#/ ,�'.DA• ;�Ails' Ay I,l� .sY�l� lX3s'ONO 44 ., \X < • o J \ - - - - - N I EXTERIOR DETAILS <br /> SOLDERED FOLDED SEAM <br /> I i <br /> ��� CONCRETEPIER-SEE STRUCT kr <br /> FORREINFORCING&FOOTING 1.- <br /> � I' <br /> J 11J <br /> Ill <br /> a FINISH GRADE z \ <br /> / <br /> ,_ <br /> `7 LINE OF CMU BASE BELOW Q li PROJECT NO. <br /> O n \ / SOLDERED DOWN <br /> z • <br /> SPOUT FLANGE 18.03-01 <br /> CT, 4 SODERED FOLDED SEAM <br /> _ 8 X 10 X 16 DEEP DATE <br /> R ` _ _ \ SOLDERED DOWN PIPE SLEEVE I PREFINISHED METAL n I\ <br /> 1 O s= DOWN SPOUT SLEEVE 12/21/2018 <br /> 4 ✓ �`� CONDUCTOR BOX A <br /> _.._--- r; , / n / " ,�'n FLANGE. .•...I. ('. .:. 1,'.1..1 ... . . ........r : r .... .: . I -� vQ O PROJECT NETWORK PATH <br /> 9 3/4' 4 9 3/4 1 OVERRAN ► G 1 I <br /> �, 1' 11 1/2" II G N \ _ VERFLOW 2 ABOVE BASE OF `=~ ,Ii SOLDERED DOWN SPOUT O��'< <br /> EACH WAY LINE OF BEAM ABOVE -�,�, / / �XSCUPPER. FLANGE. 0 0 60 _ 4" DIA PREFINISHED <br /> 3" 2" 2" 3" <br /> METAL <br /> DOWNSPOUT <br /> 1/2" 1/2" ,� 4"0 PREFINISHED METAL f SHEET NUMBER <br /> EXTERIOR COLUMN BASE - SECTION EXTERIOR COLUMN - PLAN SCUPPER DETAILS ` DOWNSPOUT r <br /> 0-7) _,__ <br /> 1 1/2"= 1'-0" 1 1/2"= 1'-0" 1 1/2" = 1'-0" <br /> A8 . 02 <br /> COPYRIGHT©2019 shoesmith cox architects <br />