My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2235 LAKE HEIGHTS DR 2018 Plans 2022-11-22 (2)
>
Address Records
>
LAKE HEIGHTS DR
>
2235
>
Plans
>
2235 LAKE HEIGHTS DR 2018 Plans 2022-11-22 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 3:36:30 PM
Creation date
7/22/2021 8:28:05 AM
Metadata
Fields
Template:
Address Document
Street Name
LAKE HEIGHTS DR
Street Number
2235
Permit
B1812-021
Year
2018
Notes
Addition of 7,165 SF To North / And 6,900 SF to South
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4„ NOTE: h <br /> 1. GENERAL CONTRACTOR SHALL BE RESPONSIBLEVERIFYING THE <br /> FOR S o e s m t h <br /> FLASHING OVER END L7---- <br /> THROAT SIZE REQUIREMENTS <br /> OF PANEL � _ <br /> 4SiallSION POINT I 2. DOOR AND FRAME FINISHES PER DOOR SCHEDULE <br /> LAP MOISTURE BARRIER II 3. HARDWARE,WEATHER STRIPPING, SMOKE SEALS,AND ACCESSORIES PER ■ <br /> OVER FLASHING &TAPE NI DOOR SCHEDULE. �]Q r r h I <br /> CONT. SEALANT BED V totsQBTWN MTL. FLASHING& 4. WALL AND FLOOR FINISHES PER FINISH SCHEDULE. <br /> WRB I 1928 43rd Ave E., Ste A <br /> CEMENT FIBER SIDING 5. SEE STRUCTURAL FOR ALL HEADER AND JAMB POST SIZES. Seattle , WA 9 8 1 1 2 <br /> �1 ( 2 0 6 ) 453 . 4053 <br /> CONT. INSECT SCREEN -- JI / HEADER PER s h o e s m i t h c o x . c o m <br /> OPEN FOR DRAINAGE / STRUCTURAL <br /> ..... \ / <br /> EN \ / \/ 1 <br /> Lam-®* <br /> 24 GA MTL FLASHIING WI \ ,>rt <br /> 1/4" HEMMED EDGE, END <br /> 2" <br /> DAMS&4"VERTICAL LEG <br /> EXTEND TO OUTER EDGE SPRAY FRAME <br /> OF JAMB TRIM TYP. WITH CLOSED <br /> CONT. SEALANT CELL <br /> INSULATION <br /> DOOR FRAME W/INTEGRAL FOR AIR <br /> WELDED METAL FLANGES PER II BARRIER <br /> SCHEDULE <br /> 12 EXTERIOR DOOR HEAD AT TRANSOM <br /> SEE 1/A10.05 FOR ADDITIONAL NOTES AND SEQUENCING. 3"= 1-0" <br /> PER WALL TYPE <br /> if, X PER WALL TYPE <br /> EXIST. WALL I I <br /> HEADER PER STRUCTURAL \ II 1 - � \t <br /> LAP MOISTURE BARRIER �r-�,. -R i <br /> - ( bethany <br /> OVER FLASHING&TAPE ~ PER STRUCTURAL <br /> \II -------..._ / -4 ' <br /> CONT. SEALANT BED I ' ii <br /> WRB <br /> MTL FLASHING & \� Iri I ,i skilled nursing <br /> -- <br /> xPAINTED WOOD TRIM XI \ - <br /> CEMENT FIBER SIDING II -- ' — _ — _ additions <br /> CONT. INSECT SCREEN <br /> \ ��" , -- — -HOLLOW METAL FRAME,FINISH a co <br /> f \ PER SCHEDULE <br /> - \ a `�- . 2235 Lake Heights Drive <br /> 24 GA MTL FLASHIING W/ 2, ' \� � \~ 1 Q Everett, WA 98208 <br /> 1/4 HEMMED EDGE, END N 1 <br /> DAMS &4"VERTICAL LEG /4/ <br /> EXTEND TO OUTER EDGE FLUSH METAL DOOR FRAME- FINISH <br /> OF JAMB TRIM TYP. PER SCHEDULE SILENCERS OR SMOKE GASKET, <br /> PER SCHEDULE <br /> CONT. SEALANT <br /> DOOR FRAME W/INTEGRAL DOOR PER SCHEDULE <br /> WELDED METAL FLANGES PER <br /> DOOR PER SCHEDULE <br /> SCHEDULE <br /> DOOR PER SCHEDULE <br /> SPRAY FRAME WITH CLOSED CELL <br /> INSULATION FOR AIR BARRIER Bethany <br /> 011 EXTERIOR HOLLOW METAL DOOR HEAD 7 INTERIOR DOOR JAMB / HEAD AT EXIST. INTERIOR HM DOOR JAMB / HEAD <br /> 3 1 0 3 = 1-0 PER WALL TYPE 3"= 1'-0" of the Northwest <br /> PER WALL TYPE PER WALL TYPEx NO. DATE REVISION <br /> I HEADER PER STRUCTURAL <br /> PER STRUCTURAL BARN DOOR HARDWARE I\\/ -..---7 <br /> I N. <br /> / 1 , N I _ ,s, <br /> ›...<----- 1 <br /> II ,. 'y <br /> _____� ,-__ 1x4 PAINTED WOOD TRIM - <br /> it I \ <br /> CEMENT FIBER SIDING II —>�— �■ <br /> ,\ r <br /> ALIGN ;NI <br /> METAL F CLOSURE \ �E. �� \` \ <br /> m / S DOOR PER SCHEDULE-NOTE THAT ; <br /> BACKER ROD&SEALANT ))�I ��_ Q `- n: DOOR LEAF IS 6 INCHES WIDER THAN <br /> �� ,,�, -' �� < OPENING, SIZE BARN DOOR <br /> / I- Q HARDWARE ACCORDINGLY- <br /> CV <br /> r T;` <br /> \ \ <br /> FLUSH METAL DOOR FRAME- FINISH <br /> PROJECT MANAGER <br /> 11 PER SCHEDULE BASE PER SCHEDULE JS <br /> PROJECT ARCHITECT <br /> PER STRUCTURAL <br /> VERIFY SLOT DIMENSION WITH JS <br /> DOOR PER SCHEDULE PROJECT TEAM MEMBERS <br /> DOOR FRAME W/INTEGRAL TRACK MANUFACTURER <br /> WELDED METAL FLANGES PER �- TS <br /> SCHEDULE <br /> CHECK <br /> DOOR PER SCHEDULE FLOOR TRACK ALONG WALL- <br /> \"----. <br /> SPRAY FRAME WITH CLOSED CELL <br /> NONE AT OPENING __„, g <br /> INSULATION FOR AIR BARRIER ..;'` <br /> EXTERIOR HOLLOW METAL DOOR JAMB c INTERIOR DOOR JAMB / HEAD BARN DOOR HEAD / TRACK ARCHITECT SEAL <br /> CD 3"= 1'-0" 3" = 1'-0" 1 2 <br /> 3"= 1'-0" 7534 <br /> PER WALL TYPE <br /> ,' ,t REGISTERED <br /> PER WALL TYPE _PER <br /> FLOOR STOP TO PREVENT \ <br /> OVERRUN <br /> A. SMITH <br /> GLAZING PER SCHEDULE STATENOF WASOHENGTON <br /> FLUSH METAL RELITE S`` <br /> FRAME-PAINT DOOR PER SCHEDULE <br /> DOOR PER SCHEDULE (2)STUDS AT JAMB <br /> CITY EVERETT <br /> N' 1x4 PAINTED WOOD TRIM ` REVIEWED FOR PERMIT <br /> ■ C ■ <br /> FLOOR FINISH PER FINISH SCHEDULE d m fill TITLE <br /> Q __- �_i , PER STRUCTURAL I` r----------__`_ DOOR <br /> STOP STRIP _ f- - ' GWB WRAP <br /> WEATHERSTRIP \ ,:r < <br /> N <br /> J-BEAD AT ALL CORNERS,TYP. "-- <br /> DETAILS <br /> SWEEP <br /> % '_ -_. <br /> DOOR PULL EACH SIDEilMINNIIMIIIIMIIIIIIMEMI PROJECT NO. <br /> THRESHOLD FLUSH METAL DOOR N 18.03-01 <br /> FRAME - PAINT <br /> DATE <br /> kr <br /> _ II II 'f rI' II II+ DOOR PER SCHEDULE ( ) \ 12/21/2018 <br /> 2 U MIMI I. IIII11I1IN1111IIIIAAA�II PROJECT NETWORK PATH <br /> EN <br /> SMALL BACK DAM AND FF SAM . .g' <br /> SHEET NUMBER <br /> 3'-0"CLEAR TO <br /> °THRESHOLD AT HOLLOW METAL DOOR 5 INTERIOR DOOR / RELITE E9BARN DOOR JAMB OPPOSITE JAMB <br /> 3 1 0 3 = 1-0 3"= 1-0" Al 0 . 03 <br /> COPYRIGHT©2019 shoesmith cox architects <br />
The URL can be used to link to this page
Your browser does not support the video tag.