ROOF FRAMING PLAN NOTES <br /> 1. GENERAL 2. ROOF 2.2. TYPICAL RIM JOISTS SHALL BE MINIMUM 1 1/2" LSL, UNO. REFER TO SHEAR WALL SCHEDULE f� <br /> FOR ADDITIONAL REQUIREMENTS AT RIMS. till <br /> 2.1. ROOF SHEATHING SHALL BE 19/32" APA RATED SHEATHING (32/16), EXPOSURE 1. UND <br /> 1.1. ELEVATION AT TOP OF SHEATHING SHALL BE PER ARCH. <br /> REFERENCE ARCHITECTURAL PLANS FOR FIREPROOF SHEATHING REQUIREMENTS. 2.3. TYPICAL HEADER SHALL BE 4x10 DF NO. 2, UNO. <br /> 1.2. GRID LINES ARE TO FACE OF STUD AND CENTERLINE OF COLUMN. REFER TO ARCHITECTURAL <br /> 3 r SAHL <br /> DRAWINGS FOR DIMENSIONS NOT SHOWN. NAIL SHEATHING AS FOLLOWS: 2.4. SHEATH INSIDE OF PARAPET WALLS WITH 15/32" SHEATHING WITH 10d @ 6" AT PANEL EDGES <br /> /� AND AT ALL FRAMING MEMBERS. <br /> ROOF BOUNDARY(BN) 10d @ 6" \ 1201 First Avenue South, Suite 310 <br /> PANEL EDGES (EN) 10d @ 6" 2.5. TRUSSES SHALL BE PREFABRICATED WOOD TRUSSES ENGINEERED BY OTHERS. REFER TO <br /> OTHER SUPPORTS, FIELD NAILING 10d @ 12" STRUCTURAL GENERAL NOTES FOR ADDITIONAL REQUIREMENTS. Seattle, Washington 98134 <br /> 206-402-5156 www lundopsahl.com <br /> BLOCKING, INTERIOR RIM JOISTS &STRUTS 10d @ 6" <br /> 2.6. TRUSSES SHALL BE DESIGNED FOR A 500 LB BOTTOM CHORD LOAD AT LOCATIONS NOTED. <br /> NAILS SHALL BE FLUSH WITH THE FACE OF SHEATHING. 3., REFERENCE MECHANICAL DRAWINGS FOR EXACT LOCATION AND EXTENTS. REFER TO <br /> STRUCTURAL GENERAL NOTES FOR ADDITIONAL REQUIREMENTS. <br /> g 7 6 0 0 3 q <br /> 1.1 10.80 E3Engineer's Stamp <br /> 0 0Q 0Q0 <br /> I k <br /> / / i 13' 6" 2 1/8" 13' 3 7/8" 14' 7" 26' S 1/8" 8' 2" 26' S 1/8" <br /> / / X <br /> 12' 6" 13' 0" 13' 6" 8' 6 3/4" 1 <br /> N.4r. <br /> I I , A• °ASS' <br /> 11 <br /> /� r,��ss r 1���, <br /> F-:---401 <br /> Nz � <br /> 2 b/ til i'i/P > 5 — — — <br /> i I I li 11'..* 1,-- <br /> H \ — — — r — _ 1 _ _ 23— — J _,�,i `— — — — — — — — — 4111 <br /> :Q. L sty <br /> c,T 24234 G��� � <br /> Fr 1 <br /> 0 CMSTC16 A�2' - 01 CMST �P `':t ��. <br /> � � � �� i_ • G O ALA <br /> 41.1 1 2 I <br /> / a a / f ' GT <br /> 1: o i' <br /> A, > N/ Ln : b <br /> t, Project Title <br /> ' GT o o Om Q , + + + + + I I N <br /> N S6.02 ++ + + + <br /> ,!_,_,:, <br /> "' `" TYP 8 TYP ROOF SHEATHING u ,�.,;« + ++* * ++*+ <br /> m UNO PER NOTE 2.1. Qt , +++ + 10'+ <br /> � ��' - U 0 S6.o5 S6.05C <br /> N ^ + S6b-5 + <br /> 5 1/ 10 1/2 GLB 5 1/2 x 10 1/2 GLB ^ 5 1/2 x 10 1/2 GLB ^ 2.6 =F +++'++ . I I I <br /> `-0 • ...... <br /> Ora , -- —. _— "-___ __ / '::*++++ +++++*+* - <br /> O\ rr___ — - -- -- — —cc I-' 3 `\ H- 1/; oI 'M+*+*+* * *+++ <br /> SOME <br /> CD�\ _ _ + + + + \ 0 <br /> 5 /2 x 10 1/2 GLB 5 1/2 x 10 1/2 GLB 5 1/2 x 10 1/2 GLB 5 1/2 x 10 1/2 GLB 1• E. ' ` ;*++++++±++++ + — — — — — — — — v\ <br /> 0 <br /> O <br /> \ � _ 56.03 i/ I+I++'++***++ HDR LOW <br /> 2----- <br /> dirk <br /> re• a) <br /> + + + + + + <br /> + + + + + <br /> ,.., F., z\ G).. i , <br /> , 2' - '" I I Al1p++ +'1 1+*+++ �,, oo <br /> j \ N C STC16 , Alt <br /> n <br /> b GT <br /> ^ o ` ++* ++* ;*+* ++*+*+* HDR LOW <br /> // ///' I , — — — — — - - • 0 •— <br /> Nr _c, > / 7/////7 CMSTC16 � � ( ) I I I <br /> _JT I _ / _ o16" TJI 360`� _ _ - 0/ o\ @24" OC�// /\////, <br /> % _W— ADD OR REPLACE SHEATHING CD <br /> iv / / ���\ '. N'r 8 ' ' AT(E) ROOF PER PER 9/S6.02, I C O 01 <br /> �f� � 4 56.02 11/S6.02, SEE NOTE 2.1. • = Q <br /> _ it _1r v !%� , , �, — 56.04 _ 3� • <br /> �� <br /> O \ — I <br /> „ 2xBLKG VL`� �� _ 2' 0 H2O"" DT(2.5 kips) <br /> / 1 3/4 x 16 L ^ <br /> CMSTC16 N CMSTC16 0 8 ' I I I n) mg <br /> m L_ <br /> \ N S6.o4 M N > <br /> `° W N L LJ <br /> , fV <br /> o / / ROOF SHEATHING iJi, o16"TJI 210 <br /> /2ASf "Pt- -re PQavrdC @ 24" OC <br /> N � <br /> PER NOTE 2.1. II I I I Project Information <br /> AD L /r/L4fitri✓4 so SAPPoit / Nl 10 <br /> �2Ays7C J'/ �rNrivE',� 7'S�i° //// /// Project No. 18 098 01 <br /> 13/4x16LVL 56.04 j- DT(2.5 kip ) m- - — \ J/ I I Checked By BB <br /> �;J � 4 I I I <br /> b /' r/. S6.04 I Issue <br /> o -.1 / RT <br /> m <br /> m CMSTC16 b PERMIT SET 12/21/2018 <br /> I I I A DOH CRS RESPONSE#1 01/28/2019 <br /> \ o N -2' 1" <br /> CITY RESPONSE#1 03/29/2019 <br /> CD1 DT(2.1 ip ) di: 3/4 6 LVL� — /\ CITY RESPONSE#2 05/31/2019 <br /> v — — — — — — — — GT — 2' - 0' X �' C TC16 OPP <br /> ^. 6 <br /> „JT <br /> m J - <br /> T� 56.04 <br /> in J <br /> o,CI \ i its ,_ <br /> 2' 0„i 2' 0" <br /> I I I I <br /> 1- CMSTC16 <br /> O > <br /> 8 I <br /> 5 <br /> o @ 16" OC ' I <br /> 5 <br /> LEGEND 5 0 <br /> 12 7 Department Approval <br /> s STRUCTURAL WALL BELOW WITH LS90 1 + * + +++++ <br /> I <br /> HEADER(CONT WALL PLATES) 2x10 INFILL @ 16FRA"MOCING w/ I S6.05 S6.1' ' + 1i++ + +++++++++ it I I <br /> + +S5�+ + + + + + II <br /> r== STRUCTURAL WALL BELOW WITH FLUSH0 Pr 2x10 FASCIA \' * +*�++`++ ++`+++�+ — — — 11 I i— — I — — 4 — I — — — — <br /> BEAM (BREAK WALL PLATES) + ++ _ ++`+++++`+ + + + ++ + + + + + + + + + + - +:� �• + + + + + + <br /> + + + + + + + + + + + + + + + + + + + + + + CIT�� U� EVE <br /> FLOORJOIST & EXTENTPERNOTE 2.X. N � + * + 1++++>+- <br /> H2.5A,TYP 11 ++' I + REVIEWED- +�+ + *+'++ * + '+`+* `+++1-*+*++++++*+*+*+++ +++ + <br /> E) R�. ORS' <br /> BEAM PER PLAN OR HEADER PER NOTE 2.X. ,NI <br /> �+ + + * * * * * * * * * * + + + *++ + + + + I I I <br /> 4x12 DF#2 HEADER ' ++ ++:.tiFA/fING + ++++++++*+++++ ++*+++*+ +*+ ++++*+*+*+ +* ++++++++*+*+*+*+++++*+* <br /> 1 JOIST HANGER PER NOTE 2.X. 3,, <br /> �— ADD ORREPLACESHEATHING <br /> AT(E) ROOF PER PER 9/S6.02, + + * '. + -- * * + * �* + + + + *_ * + + + Vail 'qire <br /> * * + + + • + + + + + + + + + * <br /> j/ A INDICATES OVERFRAMING (3 psf SUPER-IMPOSED) 11/S6.02, SEE NOTE N <br /> Sheet Title <br /> LS90 .. <br /> ... D <br /> ++++++++++++ ADD OR REPLACE SHEATHING AT EXISTING /3,. . NORTH ADDITION <br /> + + + + + + Eri <br /> ROOF FRAMING <br /> RT INDICATES PRE-ENGINEERED ROOF TRUSS REMOVE (E) BEAMS <br /> @ 24" OC. PLAN <br /> GT INDICATES PRE-ENGINEERED GIRDER TRUSS. <br /> DT INDICATES PRE-ENGINEERED DRAG TRUSS. Sheet Number <br /> SEE DETAIL 5/S6.05. <br /> JT INDICATES PRE-ENGINEERED JACK TRUSS <br /> @ 24" OC. <br /> \l/ / <br /> ROOF FRAMING PLAN - NORTH ADDITION S2 • O4 <br /> Scale: 1/8" = 1,_0,. <br /> North <br />