My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-22 Plans 2022-11-30
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-22
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-22 Plans 2022-11-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 3:00:33 PM
Creation date
7/22/2021 1:02:57 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-22
Permit
B1910-007
Year
2019
Notes
New Trenches To Support (2) New 767 Final Assembly Positions
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br /> MECHANICAL LEGEND MECHANICAL LEGEND GENERAL CONSTRUCTION NOTES <br /> LEI <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION 1 . PLANS ARE DIAGRAMMATIC 8c DO NOT SHOW ALL BRANCHES, En <br /> VALVES, SPECIALTIES & EQUIPMENT. L <br /> L <br /> A COMPRESSED AIR NC NORMALLY CLOSED <br /> AAV AUTOMATIC AIR VENT NIC NOT IN CONTRACT 2. ALL PIPING, VALVES & EQUIPMENT ARE TO BE REMOVED IN U <br /> AD ACCESS DOOR NO NORMALLY OPEN / NUMBER DEMOLITION AREAS. / <br /> ADD ANGULAR DOWN DISCHARGE NTS NOT TO SCALE <br /> AF AIR FOIL WHEEL NPSH NET POSITIVE SUCTION HEAD 3. VALVES INDICATED FOR SHUT-OFF ISOLATION ARE SHOWN IN IQ <br /> AFF ABOVE FINISHED FLOOR OA OUTSIDE AIR APPROXIMATE LOCATIONS. REFER TO REFERENCED BLDG. DRAWINGS <br /> AP ACCESS PANEL <br /> AUD ANGULAR UP DISCHARGE OBD OPPOSED BLADE DAMPER FOR DETAILED SYSTEMS. <br /> AVG AVERAGE OF OVERFLOW 1` <br /> OS&Y OUTSIDE SCREW AND YOKE 4. FIELD VERIFY EXACT LOCATIONS VALVES, EQUIPMENT 8c PIPING. CD <br /> BI BACKWARD INCLINED WHEEL OD OUTSIDE DIAMETER BDD BACK DRAFT DAMPER 5. CONTRACTOR TO VERIFY SYSTEM SHUT DOWN PRIOR TO ANY <br /> BFP BACKFLOW PREVENTER PBD PARALLEL BLADE DAMPER REMOVAL WORK. <br /> BHD BOTTOM HORIZONTAL DISCHARGE PD/o P PRESSURE DROP OR DIFFERENTIAL PRESSURE I- <br /> BHP BRAKE HORSE POWER POS POSITION 6. CONTRACTOR TO RE-OPEN VALVES AFTER COMPLETION OF REMOVAL, <br /> BOD BOTTOM OF DUCT PRESS PRESSURE CAP, & CUT TO RESTORE SYSTEM OPERATION WHERE REQUIRED. CY <br /> BOP BOTTOM OF PIPE PRV PRSSURE REGULATING VALVE W <br /> BOS BOTTOM OF STEEL PS PRESSURE SWITCH 7. SYSTEM SHUT DOWN REMOVAL, CUT & CAP SHALL ONLY BEGIN n <br /> BTU BRITISH THERMAL UNIT PSIG PRESSURE - POUNDS PER SQUARE INCH, GAUGE AFTER NEW, RE-ROUTED SYSTEM IS IN PLACE FOR SERVICE <br /> BTUH BRITISH THERMAL UNIT PER HOUR PSV PRESSURE RELIEF (SAFETY) VALVE CONTINUITY WHERE REQUIRED. O <br /> BW BUTTWELD <br /> RA REVERSE ACTING (CONTROLLER) / RETURN AIR 8. ALL SYSTEMS SHALL BE DRAINED & DISPOSAL OF FLUIDS HANDLED <br /> C COMMON RECT RECTANGULAR W <br /> Cv FLOW COEFFICIENT REF REFERENCE AS REQUIRED PER BOEING STANDARDS. UD <br /> `C TEMPERATURE - DEGREES CELSIUS RH RELATIVE HUMIDITY 9. AN ATTEMPT WAS MADE TO SHOW MAJOR MECHANICAL UTILITY WORK (I) <br /> CAP CAPACITY RM ROOM <br /> CC COOLING COIL ROT ROTATION WITHIN THE PROJECT'S BOUNDARIES. THE CONTRACTOR IS <br /> CCW COUNTER CLOCKWISE ROTATION RPM REVOLUTIONS PER MINUTE RESPONSIBLE FOR REMOVAL/DISPOSAL OF ALL MECHANICAL WORK <br /> CFM CUBIC FEET PER MINUTE RQD REQUIRED <br /> WITHIN THE PROJECT'S BOUNDARY. <br /> CI CAST IRON RTN RETURN <br /> CENTER LINE <br /> CONN CONNECTION SA SUPPLY AIR <br /> CPLG COUPLING SCFM CUBIC FEET OF AIR, AT STANDARD CONDITIONS <br /> CW CLOCKWISE ROTATION SCV SAFETY CHECK VALVE <br /> SHC SENSIBLE HEAT CAPACITY <br /> DA DIRECT ACTING SHE SENSIBLE HEAT FACTOR <br /> DB DRY BULB TEMPERATURE SO SCREENED OPENING <br /> DBD DOWN BLAST DISCHARGE SOV SOLENOID OPERATED VALVE <br /> DIA, DIAMETER SP STATIC PRESSURE <br /> DN DOWN SQ SQUARE <br /> DS DOWNSPOUT SS STAINLESS STEEL <br /> DWG DRAWING STL STEEL <br /> dB DECIBELS SW SOCKET WELD <br /> EA EXHAUST AIR / EACH SUCT SUCTION <br /> EAT ENTER AIR TEMPERATURE (`F) SV SAFETY RELIEF VALVE <br /> EFF EFFICIENCY TDH TOTAL DYNAMIC HEAD (FEET OF WATER) <br /> ELL ELBOW TEMP TEMPERATURE <br /> ELEV, EL ELEVATION TH TOTAL HEAD (FEET OF WATER) <br /> ESP EXTERNAL STATIC PRESSURE THC TOTAL HEAT CAPICITY <br /> EVAP EVAPORATOR THD TOP HORIZONTAL DISCHARGE <br /> EWT ENTERING WATER TEMPERATURE THRD THREADED <br /> EXH EXHAUST TOD TOP OF DUCT <br /> EXIST EXISTING TOS TOP OF STEEL <br /> EXT EXTERIOR / EXTERNAL TOP TOP OF PIPE <br /> TP TOTAL PRESSURE <br /> `F TEMPERATURE - DEGREES FAHRENHEIT TS TEMPERATURE SWITCH <br /> FC FORWARD CURVE WHEEL TSP TOTAL STATIC PRESSURE <br /> FLR FLOOR TV TURNING VANE <br /> FOB FLAT ON BOTTOM TYP TYPICAL <br /> FOF FACE OF FLANGE <br /> FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR UBD UP BLAST DISCHARGE <br /> FOT FLAT ON TOP ° <br /> FPM FEET PER MINUTE VAV VARIABLE AIR VOLUME <br /> FS FLOW SWITCH VD VOLUME DAMPER <br /> FT FEET VP VELOCITY PRESSURE <br /> FV FACE VELOCITY FPM VERT VERTICAL <br /> VTA VENT TO ATMOSPHERE <br /> GAL GALLONS VTR VENT THROUGH ROOF <br /> GPM GALLONS PER MINUTE <br /> GALV GALVANIZED WB WET BULB TEMPERATURE <br /> GA GAGE, GAUGE WG WATER GAUGE (INCHES OF WATER) <br /> W/ WITH <br /> HC HEATING COIL <br /> HD HEAD - FEET OF WATER <br /> HORIZ HORIZONTAL <br /> HP HORSEPOWER <br /> HPC HIGH PRESSURE CONDENSATE NOTES: <br /> HR HOUR <br /> HVAC HEATING, VENTILATING AND AIR CONDITIONING 1 . DESIGNATES EQUIPMENT APPEARING ON MECHANICAL <br /> EQUIPMENT SCHEDULES, SEE DRAWINGS STARTING <br /> ID INDIRECT DRAIN <br /> IE INVERT ELEVATION 2. SEE <br /> NM1B F RPABBREIVIATIONS OF PIPING, <br /> IGV INLET GUIDE VANE <br /> IN INCHES 3. SEE CONTROL SCHEMATIC(S) FOR ADDITIONAL ABBREVIATIONS <br /> KW KILOWATT AND SYMBOLS RELATING TO CONTROL SYSTEMS. <br /> KVA KILOVOLT-AMPERE 4. DIFFUSERS WITHOUT ARROWS TO INDICATE AIR FLOW DIRECTION <br /> ARE FOR FLOW IN ALL DIRECTIONS (TWO DIRECTIONS FOR <br /> LAT LEAVING AIR TEMPERATURE (`F) LINEAR DIFFUSERS). ARROWS ARE USED TO INDICATE <br /> LBS, # POUNDS DESIRED AIR FLOW DIRECTIONS IN OTHER CASES. <br /> LWT LEAVING WATER TEMPERATURE CO <br /> MA MIXED AIR <br /> MAX MAXIMUM ala 6,- '' ''‘., <br /> MBH HEAT CAPACITY BTU PER HOUR X 1000 <br /> MCC MOTOR CONTROL CENTER <br /> MIN <br /> MINIMUM <br /> MOV MOTOR OPERATED VALVE <br /> } <br /> MID, MTG MOUNTED, MOUNTING www.brph.com Copyright©2019 <br /> Architects Engineers, Inc. <br /> 19020 33rd Ave W,Suite 530 State of Washington <br /> PROFESSIONAL STAMP 6c SIGNATURE Lynnwood,Washington,98036 Certificate of Authorization <br /> APPLIES TO WORK WITHIN THE CLOUDED 425-921-3500 Architecture No.603235512 <br /> REVISION AREAS ONLY AS INDICATED Engineering No.3137 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY DCS 09/17/19 MECHANICAL LEGEND & ABBREVIATIONS - A 09/17/2019 <br /> A ISSUE FOR PERMIT — 767 RATE INCREASE FA DCS KMB 09/17/19 ��`Sx wa � THIS DESIGN AND/OR CHECKED <br /> ~~ °� f'rt�' SPECIFICATION IS APPROVED DCS 09/17/19 SHEET <br /> ri i' ' <br /> ® enf1 e' rigr. � APPROVED BY DEPT. DATEKMBNEER 09/17/1g TITLE 767 RATE INCREASE - FA. CHECKED <br /> �. ,: 218 BUILDING 40-022 <br /> � JOB NO. COMP NO. <br /> '� , ,rsTv' .� 4 APPROVED EVE-18-30055-602 <br /> � �rsTc <br /> of I F� �F. \,v <br /> s`foivAL E`c APPROVED DWG NO. <br /> MECHANICAL MASTER EVERETT, WA 40-022-MOa-602 <br />
The URL can be used to link to this page
Your browser does not support the video tag.