Laserfiche WebLink
Q <br /> vECHA\ICAL LEGE\ D MECHA\ ICAL LEGE\D NECHA\ICAL LEGE\ D NEC— A\ ICAL LEGE\D NECHA\ICAL LEGE\D VECHA\ ICAL LEGEND Li__ <br /> w <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION r (f) <br /> it FLEXIBLE DUCT CONNECTION W <br /> -I RWL I- RAIN WATER LEADER —0 FCO FLOOR CLEAN OUT FIE P O TE C TI O\ H VA C IIII <br /> GE\E�AL c.) <br /> --I S I SPRINKLER LINE U CO CLEAN OUT, EXPOSED 0 SPRINKLER HEAD, UPRIGHT, NEW <br /> NEW WORK 24/1 2 RECTANGULAR DUCT, FIRST NUMBER r SIDEWALL SUPPLY AIR DIFFUSER, GRILLE, <br /> INDICATES SIZE FOR SIDE SHOWN 100 CFM OR REGISTER AND CFM AIR FLOW <br /> EXISTING WORK -i SAN I- SANITARY WASTE BELOW GRADE OR FLOOR I WASTE PIPING BEND SPRINKLER HEAD, PENDENT, IN LINE, NEW ) 24/12 f w <br /> - Q <br /> ///////// EXISTING TO BE REMOVED -I SAN H-- SANITARY WASTE ABOVE GRADE OR FLOOR I LATERAL -----ICt- SPRINKLER HEAD, PENDENT, OFFSET, NEW 24/12 DUCT SHOWN IN SECTION, ARROW POINTS SIDEWALL RETURN/EXHAUST AIR GRILLE OR <br /> HIDDEN OR BELOW GRADE --I STM r-- STEAM SUPPLY 14 SANITARY WYE AND 1/8TH BEND SPRINKLER HEAD, SIDEWALL, PENDENT, NEW �, TO SIDE CALLED OUT FIRST _ <br /> 100 CFM REGISTER AND AIR FLOW <br /> C..O <br /> I <br /> CROSSING LINES, NO CONNECTION -I STS I-- STORM DRAIN V SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW b 24 S 1—` <br /> 241ROUND DUCT, NUMBER INDICATES DIAMETER I I10�M <br /> T SCREENED OPENING AND CFM AIR FLOW <br /> CONNECTING LINES ---H VAC H- VACUUM I P I\G SPECIALTIES SPRINKLER HEAD, DRY PENDENT ff <br /> AHU EQUIPMENT MARK NUMBER ----EV ---- VENT -Da-/ GATE VALVE, OPEN / CLOSED - SPRINKLER HEAD, OVER AND UNDER b 24/12i 9 OVAL DUCT, FIRST HUMBER INDICATES I _ 1 SUPPLY OUTLET, CEILING TYPE, DIFFUSER <br /> 1111/ MAJOR DIAMETER, SECOND NUMBER 1 II - -- - OR GRILLE, SQUARE OR RECTANGULAR > <br /> -Da ANGLE GLOBE VALVE, ELEVATION / PLAN - EXISTING SPRINKLER HEADS (TO REMAIN) f 24/121 f INDICATES MINOR DIAMETER I L - -. 1400 CFM AND CFM AIR FLOW (SEE NOTE 4) I i <br /> �� PUMP W <br /> b ) INSULATED PIPE PIPE FI TTI\G S _4:) GATE VALVE OUTSIDE SCREW AND YOKE X EXISTING SPRINKLER HEADS (REMOVE) <br /> SUPPLY AIR DUCT, SQUARE OR RECTANGULAR I SUPPLY OUTLET, CEILING TYPE, ROUND <br /> Illin <br /> ELBOW FACING TOWARDS AND CFM AIR FLOW (SEE NOTE 4) rY <br /> GATE VALVE WITH HOSE CONNECTION FHC FIRE HOSE CABINET 400 CFM O <br /> --b T— INSULATED PIPE WITH ELECTRIC HEAT TRACING X I Y PIPING MATERIAL CHANGE, X TO Y - -_ <br /> L� <br /> POINT OF CONNECTION I <br /> I SCREWED FITTING OR AS SPECIFIED -DOQ-/ GLOBE VALVE, OPEN / CLOSED FDC FIRE DEPARTMENT CONNECTION, WALL TYPE SUPPLY AIR DUCT, SQUARE OR RECTANGULAR <br /> ELBOW FACING AWAY - - _INEAR DIFFUSER AND CFM AIR FLOW I I <br /> 11 a FLANGED FITTING I>r4 BALANCE VALVE PLUG FDC, „ FIRE DEPARTMENT CONNECTION, YARD TYPE - 100 CFM ;SEE NOTE 4) <br /> P 19 E I D E\ TI FI C A TI 0\ ® a WELDED FITTING C +i PRESSURE REGULATING VALVE u <br /> FDC FIRE DEPARTMENT CONNECTION, FLUSH EXHAUST, RETURN OR SUPPLY AIR DUCT - T _ <br /> ROUND ELBOW FACING TOWARDS I I ^� RETURN/EXHAUST REGISTER OR GRILLE, <br /> � 100 CFM CEILING DUCT TYPE AND CFM AIR FLOW <br /> - Al-- COMPRESSED AIR, PLANT 1+1 PIPE TEE, STRAIGHT ‘ 1 PRESSURE RELIEF VALVE / SAFETY VALVE OH FH FIRE HYDRANT - 2 HOSE OUTLET <br /> I AW' - ACID WASTE -I 0 FIRE HYDRANT - 2 HOSE OUTLET I PIPE TEE, OUTLET UP OR TOWARD I PETCOCK FH AND PUMPER CONNECTION EXHAUST, RETURN OR SUPPLY DUCT, RETURN/RELIEF GRILLE, CEILING TYPE, <br /> ROUND, ELBOW FACING AWAY --� NON-DUCTED <br /> —I C I CONDENSATE RETURN (GRAVITY) 18 1 PIPE TEE, OUTLET DOWN OR AWAY DKl <br /> -1 -BALANCE VALVE WITH METERING PORTS ASR AUTOMATIC SPRINKLER RISER <br /> 1 CF I -- — <br /> CHEMICAL FEED —III PIPE UNION 41 <br /> - SOLENOID OPERATED VALVE ¶ WMG WATER MOTOR GONG EXHAUST AIR OR RETURN AIR DUCT SQUARE <br /> �,� - --a.- UNIT HEATER, HORIZONTAL <br /> OR RECTANGULAR, ELBOW FACING TOWARDS - <br /> -I CHWR 1- CHILLED WATER RETURN II PIPE CROSS ---D% MOTOR OPERATED VALVE , ELECTRIC BELL <br /> - CHWS {- CHILLED WATER SUPPLY 1SR PIPE ELBOW, 90' SHORT RADIUS ---m SWING CHECK VALVE WITH FLOW -0 DRY PIPE VALVE <br /> EXHAUST AIR OR RETURN AIR DUCT, SQUARE O <br /> LIFT CHECK VALVE ALV ALARM VALVE, WET 1=1 OR RECTANGULAR, ELBOW FACING AWAY UNIT HEATER, VERTICAL PROJECTION <br /> - I CRV {- CORROSION RESISTANT VENT -�-- PIPE ELBOW, 90' LONG RADIUS / <br /> -I CRW I- CORROSION RESISTANT WASTE PIPE ELBOW, REDUCING -rO-I-/ BALL VALVE, OPEN / CLOSED El MONITOR SWITCH <br /> TRANSITION RECTANGULAR TO RECTANGULAR m SUPPLY AIR FLOW DIRECTION <br /> ( \ PIPE ELBOW, 45' '-J' BUTTERFLY VALVE 0FLOW SWITCH <br /> I CTFR I COOLING TOWER FILTER RETURN <br /> CTES-I-- COOLING TOWER FILTER SUPPLY 10 PIPE ELBOW, TURNED UP OR TOWARD t Z1 2 WAY CONTROL VALVE ® GC GC <br /> ® GROOVED COUPLING, GROOVED CAP <br /> RETURN, OUTSIDE OR EXHAUST AIR FLOW <br /> 'II TRANSITION AT TAKE OFF ___N_____ .. DIRECTION <br /> —re- 1-- COOLING TOWER RETURN I a PIPE ELBOW, TURNED DOWN OR AWAY A 3 WAY CONTROL VALVE - e. THRUST BLOCK <br /> -I CTS I- COOLING TOWER SUPPLY ] PIPE CAP SCREWED OR SOLDER JOINT 11III PLUG VALVE / STOP COCK ¢ PIV POST INDICATOR VALVE, YARD <br /> - 4/ TRANSITION SQUARE OR RECTANGULAR O THERMOSTAT, WALL <br /> 1 TO ROUND OR OVAL <br /> --CWI-- DOMESTIC COLD WATER D PIPE CAP, WELDED OR GROOVED D FLOAT VALVE 1WIV -+__X WALL INDICATOR VALVE, PLAN / ELEVATION OT N NIGHT THERMOSTAT <br /> -SDI DEIONIZED WATER II BLIND FLANGE <br /> QUICK OPENING VALVE O HALON SYSTEM AUTOMATIC DISCHARGE STATION UP T THERMOSTAT, CEILING <br /> I -4---- - I DUCT OFFSET UP OR DOWN <br /> WYE STRAINER (WITH DRAIN VALVE) A HALON SYSTEM, MANUAL DISCHARGE STATION R THERMOSTAT, REMOTE, CEILING <br /> I DWi DISTILLED WATER I4 PIPE PLUG DOWN <br /> I F FIRE LINE, AHEAD OF ALARM VALVE ID REDUCING PIPE FLANGE -K"\cI-- COOLING COIL CHILLED WATER I 2 WAY EARTHQUAKE BRACING - H HUMIDISTAT, WALL <br /> iiiin OPPOSED BLADE DAMPER <br /> I FOR I FUEL OIL RETURN D PIPE REDUCER CONCENTRIC DN4 HEATING COIL X 4 WAY EARTHQUAKE BRACING H HUMIDISTAT CEILING <br /> ---FTUS FUEL OIL SUPPLY b PIPE REDUCER ECCENTRIC - AAV AUTOMATIC AIR VENT (WITH DRAIN) <br /> - - Riff PARALLEL BLADE DAMPER 4D DUCT TYPE SMOKE DETECTOR <br /> [FOV 1 FUEL OIL VENT 0 X PIPE ANCHOR - MAV MANUAL AIR VENT (WITH DRAIN) CO\TOOLS <br /> IGI NATURAL GAS / PIPE HANGER PRESSURE GAUGE WITH VALVE EMCS ENERGY MANAGEMENT CONTROL SYSTEM <br /> I - 171114VOLUME DAMPER H D DUCT TYPE HEAT DETECTOR <br /> SPRING HANGER C THERMOMETER, LINE MOUNT MCC MOTOR CONTROL CENTER f \ f <br /> I HGD) REFRIGERANT HOT GAS DISCHARGE I I <br /> PIPE GUIDE 0 THERMOMETER, SEPARABLE WELL MOUNT MOTOR OPERATOR DUCT DAMPER, MOTOR OPERATED <br /> -IHPR �- CONDENSATE RETURN (PRESSURE) L; STATIC PRESSURE REGULATOR <br /> �1� (ELECTRIC OR PNEUMATIC) SR <br /> -I HPS I-- STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) FLEXIBLE PIPE CONNECTION II TEST PLUG P PRESSURE TRANSMITTER 11, <br /> I HWI DOMESTIC HOT WATER SUPPLY -WI-- 0 EXPANSION JOINT A / ® AIR DROP, SIMPLEX / DUPLEX AP DIFFERENTIAL PRESSURE TRANSMITTER <br /> T H <br /> - -D'°- BACK DRAFT DAMPER (ALLOWS TEMPERATURE SENSOR , HUMIDITY SENSOR, <br /> ttom� FLOW IN DIRECTION OF ARROW) DUCT MOUNTED <br /> (HWC I DOMESTIC HOT WATER CIRCULATING DIRECTION OF FLOW e / e AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX RCU REMOTE CONTROL UNIT BDD <br /> I HWR I HEATING WATER RETURN SLOPE .- DIRECTION OF SLOPE, DOWN :H I{ PETE'S PLUG, WITH BALL VALVE OT TEMPERATURE TRANSMITTER AD OR AP <br /> ACCESS DOOR (AD) OR ACCESS PANEL (AP) LINED DUCT <br /> ----I HWS I- HEATING WATER SUPPLY HB HOSE BIBB TRAP SEAL PRIMER VALVE CO © ■ OPERATOR WITH POSITIVE POSITIONER <br /> FILTER DIFFERENTIAL FD <br /> - NON FREEZE HOSE BIBB -- I BFPI- BACKFLOW PREVENTER ' <br /> ___ <br /> - + <br /> ---I IA I-- INSTRUMENT AIR NFHB PRESSURE SENSOR/TRANSMITTER I FIRE DAMPER ( 1 HOUR ) __= SOUND ATTENUATOR <br /> --I ID I INDIRECT DRAIN - =1 FLOW METER, VENTURI TYPE ® MAIN CONTROL AIR 20 PSIG f IFD f --- <br /> FD2 <br /> --I IW INDUSTRIAL WASTE WASTE FI TTI\GS T TRAP, FLOAT IL <br /> I + FIRE DAMPER ( 2 HOUR ) (31 <br /> 0ENTRIFUGAL FAN <br /> ---I LPG I--- LIQUID PETROLEUM GAS 0 FD FLOOR DRAIN O VALVE BOX NECHA\ICAL LEGE\D f 1FD2 f <br /> 400 AUTOMATIC FLOW CONTROL VALVE <br /> --I LPS I- STEAM SUPPLY (LOW PRESS, 0-15 PSIG) 0 FS FLOOR SINK -V (NUMBER INDICATES GPM) 1ST CHARACTER: 1 111 WITH TURNING VANES RECTANGULAR DUCT, SQUARE ELBOW *- CENTRIFUGAL FAN, INLET GUIDE VANES <br /> ---I MPS STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) amaam TD TRENCH DRAIN V = VARIABLE AIR VOLUME TERMINAL UNIT T STEAM TRAP 2ND CHARACTER: __ _t--- <br /> F <br /> --I PR CONDENSATE RETURN (PUMPED) WR C = FAN POWERED UNIT <br /> a' WASTE RECEPTOR, ROOF .A VACUUM DROP (LAB VAC) C = SHUTOFFOFF UNIT <br /> RECTANGULAR DUCT, RADIUS VANED ELBOW --- 1 FLEXIBLE DUCT <br /> --{PWI- PROCESS WATER 0 FFD FUNNEL FLOOR DRAIN 03RD CHARACTER:VACUUM OUTLET (LAB VAC) HARD PIPED E = ELECTRIC HEAT <br /> W = HOT WATER HEAT <br /> --F RD REFRIGERANT DISCHARGE RD (OFD) ROOF DRAIN (OVERFLOW DRAIN - ROOF) V VACUUM CLEANING OUTLET C = NO HEAT COIL -�- <br /> D = DUAL DUCT IL <br /> • <br /> EXTRACTION GRID <br /> --I RL}-- REFRIGERANT LIQUID -0-0 S&01VALVE IN RISER (TYPE SPECIFIED) 'Rr <br /> SAND AND OIL INTERCEPTOR I NI -�` c { <br /> 1 <br /> -I RS - REFRIGERANT SUCTION (GAS) I WCO WALL CLEAN OUT MARK NUMBER CI CO SENSOR k <br /> CO CO2 SENSOR 411111111111111 <br /> www.brph.com Copyright©2019 <br /> PROFESSIONAL STAMP & SIGNATURE Architects Engineers, Inc. <br /> APPLIES TO WORK WITHIN THE CLOUDED 19020 33rd Ave W,Suite 530 State of Washington <br /> REVISION AREAS ONLY AS INDICATED ,L nnwood Washin ton,98036 Certificate of Authorization <br /> Y 9 Architecture No.603235512 <br /> 425-921-3500 <br /> Engineering No.3137 <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY _ APPROVED DATE ACCEPTABILITY JWH 09/17/19 MECHANICAL LEGEND — A 09/17/2019 <br /> DCS KMB 09/17/19 >S� was,/��i, THIS DESIGN AND/OR CHECKED SHEET <br /> A ISSUE FOR PERMIT 767 RATE INCREASE FA1�c.°F '�i��� SPECIFICATION IS APPROVED KMB 09/17/19 <br /> F �, m , � ENGINEER TITLE IV10b <br /> �`' `; s ` ` �t c�! APPROVED BY DEPT. DATE KMB 09/17/19 767 RATE INCREASE — FA <br /> r.L CHECKED <br /> ' 3 � -' BUILDING JOB N0. COMP N0. <br /> ,I-i F 218r 7,,� APPROVED �' <br /> �� he EVE-18-30055-602 <br /> :.:.slovAt � . APPROVED DWG NO. <br /> MECHANICAL MASTER EVERETT, WA 40-022—MOb-602 <br />