Laserfiche WebLink
480V, 3PH, 3W, 60HZ INCOMING SERVICE L=G = \ D NOTES: 1 . SEVEN CONDUCTOR CABLE FOR 400HZ USE SHALL BE FACTORY Li_ <br /> SEE DRAWING 45-23-E4F ASSEMBLED WITH SIX (6) STRANDED COPPER PHASE CONDUCTORS <br /> WITH 600V XHHW INSULATION TWISTED ABOUT A NEUTRAL <br /> CONDUCTOR OF THE SAME SIZE, INSULATION TYPE AND MATERIAL o <br /> G \ RA L \ OT=S (SEE NOTE 2). <br /> 600A DISCONNECT SWITCH °' <br /> 600A DISCONNECT SWITCH 2. IN ALL CASES THE CONDUCTORS OF THE SEVEN CONDUCTOR Iz <br /> .., 7 <br /> I R -F= R = \ C = DRAW \ G S DIRECTION BLE SABOUT THE NEUTRAL CONDUEMBLIES SHALL BE CCTOR AN ABC OR IN A E <br /> EQUIVALENT IDENTIFICATION SCHEME AND LIKE PHASE CONDUCTOR <br /> _ PARALLELED AT SOURCE AND LOAD TO ENSURE THAT THE <br /> (2)3"C,(3)350kcmil + #1/0 GND EA (2)3"C,(3)350kcmil + #1/0 GND EA CO \ STD CTI 0 \ \ OT=S PARALLELED ARE OF LIKE PHASE CONDUCTORS WILL HAVE A E--- <br /> RESISTANCE AND INDUCTIVE REACTANCE HALF THAT OF A SINGLE <br /> PROVIDE CONDUIT AND CONDUCTORS IN PHASE CONNECTOR (SEE DETAIL "A"). w <br /> KATO HORIZONTAL SYNCHRONOUS TRENCH FROM GATE BOX TO JUNCTION BOX °- <br /> WHERE STINGER CABLE CONNECTS. 3. TRIPLEX CABLE SHALL BE FACTORY ASSEMBLED WITH 3 STRANDED <br /> MOTOR GENERATOR (MG) COPPER CONDUCTORS WITH XHHW INSULATION TWISTED OVER THEIR L- <br /> OPH, P- RE-USE AND RELOCATE EXISTING 75KVA LENGTH THE AMOUNT OF TWIST SHALL BE THAT REQUIRED TO w <br /> INPUT: II F880V, 3LA = 445A3W, 60Hz CI400HZ GATE BOX. SEE 1E161 FOR NEW PROVIDE A COMPACT CROSS SECTION (DETAIL "B') <br /> LOCATION. (r) <br /> OUTPUT: 400KVA/300KW0 <br /> Y <br /> 4. TRIPLEX CABLE AND 7 CONDUCTOR CABLES LESS THAN 50' IN <br /> © PROVIDE 30 FEET OF STINGER CABLE WITH LENGTH MAY BE FIELD ASSEMBLED IN THE SAME MANNER AS THE <br /> 575V, 3PH, 4W, 400Hz CONNECTOR FROM J-BOX IN TRENCH TO FACTORY ASSEMBLED CABLES EXCEPT USING SINGLE CONDUCTORS <br /> FLA = 400A ° DABICO POPUP AT AIRCRAFT. TAPED OR TIE WRAPPED TOGETHER AT 20" INTERVALS TO MAINTAIN <br /> UNDISTRIBUTED NEUTRAL °) Lt.] L�J o) THE SYMMETRICAL CROSS SECTION. <br /> GROUND TO SAME POINT AS MG SETS 5. REFERENCE TELEDYNE INET NO. 1004395642 <br /> 1 " CONDUIT WITH PARALLELING Z5V22-14G3-D <br /> 3" AL. C,(6)250kcmil + 1 0 GND --� CONTROL WIRES, SEE KATO �, 400HZ DISTRIBUTION PANEL <br /> / DWG. #653-76001 -23 3" AL. C,(6)250kcmil + #1/0 GND ji (BY INET) <br /> GROUND BUS <br /> - 600AF I 600AF <br /> 0 <br /> 600AT o) 600AT 0) <br /> 575V, 800A, 30, 3W, 400HZ BUS <br /> I 1 .- 1 <br /> 250AF b 250AF 150AF o 150AF b 1 <br /> 150AF � 150AF � 250AF � 150AF b1 <br /> 150AF 150AF 1 1 <br /> 250AT •) 250AT ') 100AT •) 100AT •) 100AT •) 100AT •) 250AT •) ) o) ®) <br /> 100AT 100AT 100AT <br /> FUTURE <br /> SPARE SPARE <br /> 3-1/2"ALC, 7C#4/0 <br /> 3-1/2"ALC,7C #2/0 3 1/2"ALC, 7C #2/0, 1#2G 1 1/2" AL. CONDUIT 3 - #2 + 1 #6 GND -- -- 3 - #2 + 1 #6 GND <br /> 3 #1/0 +1 #4 GND 1 -1/2 AL. CONDUIT 1 -1/2 AL. CONDUIT <br /> TO SERVICE CABINET SERVICE CABINET BY TO SERVICE CABINET TO SERVICE CABINET TO SERVICE CABINET <br /> AT COLUMN E3 INET; LOCATED ON - AT COLUMN G1B AT COLUMN G3 AT COLUMN E1A <br /> OTHERWISE SAME 1ST DECK OF TOOL 150AF • OTHERWISE SAME OTHERWISE SAME OTHERWISE SAME <br /> AS E1 B 34FME65B00040 AT N/A ) AS E4.5 AS E4.5 AS E1 B <br /> COL. D.4/8.5 I I <br /> GATE SERVICE I— _ • I LDC I <br /> 250AF • 180KVA 15-0AF !A - - GATE SERVICE <br /> r---- - - _ _ <br /> 250AF • <br /> 575V 30 3W © o ) 180KVA <br /> N/A 204�118V N/A ) gpgT 75 KVA, 575V I 121575V 30,3W I CENTER NEUTRAL CONDUCTOR <br /> 1200/115V �� I I o 2Q4/�118V I CONDUIT <br /> I o I 100AF I 2( <br /> T = 75 KVA, 575V ,� CONTROL '�` ' <br /> SERVICE CABINET 200/115V , CONTROL 0 0 • LOGIC GND WIRE PULLEDE <br /> 90 KVA 90 KVA CONTROL LOGICSEPARATELY WITH <br /> BY INET � CIRCUITS PROTECTION 90 DC KVA 90 KVA CONTROLLO CABLE INTO CONDUIT <br /> LDC LDC LOGIC PROTECTION <br /> PROTECTION IC I <br /> f CIRCUITS OL UBL SC. PROTECTION <br /> CIRCUITS 1 OL UBL SC. 1 I ( I I CC ECTION I (AM" <br /> LIKE PHASE <br /> ( I 1 OV/UV) I C CIRCUITS %Lir <br /> ( (OL,UBL,SC. NAV) Q <br /> < OV/UV) EPO ro <br /> C (OL,UBL,SC. VP <br /> PARALLELEDSAT SOURCE <br /> 0 O OV/UV) EPO & LOAD <br /> 0 1 o <br /> K <br /> I <br /> 1 I I ° I I <br /> I ( ° I 0O _ ” ” <br /> `� D _TAI A <br /> I I <br /> • I <br /> • SCALE: NONE <br /> #4 AWG. Li_ - ---_1 #4 AWG. TO TB #4 AWG. . <br /> 4- 1— : - <br /> TO LOCAL GND. #4 AWG. TO TB LOCAL GROUND <br /> TO LOCAL GND <br /> LOCAL GROUND - <br /> 3-1/2"C ALC, _ CONDUIT <br /> 7C #2/0, 1#2G 7 o <br /> 3-1/2"ALC, 7C 2 0 1 2G -� N4/OL+CONDUIT NC--'' 8 #14 IN 3/4" AL CONDUIT <br /> 11110.- / # / # GND WIRE PULLED <br /> SEPARATELY WITH <br /> ® ® CABLE INTO CONDUIT <br /> ® 7#2 & 1#4 GND O JUNCTION BOX <br /> © AIRCRAFT CABLE -- O (BY INET) AIRCRAFT CABLE • fi <br /> (T(P) - © AIRCRAFT CABLE 100A 0 (TYP) v o <br /> '., r PANEL °) 100A ' rl., f., 00 <br /> \_._ <br /> C 1 30A 30A <br /> EAN3114B ❑ C <br /> o o Pl., RECEPTACLE 99 l) <br /> 767 FA WEST 767 FA WEST 767 FA WEST 30A 20A 40-23 40-23 D =TA I L B <br /> COLUMN El COLUMN El COLUMN D3 <br /> ❑ COLUMN G1 COLUMN G1 SCALE: NONE <br /> 0 0 0 0 <br /> Z2V22-D.4/8.5-T1 <br /> , <br /> LOCATED ON 1ST <br /> -i P 71. ^,_ <br /> DECK OF i; <- <br /> TOOL 34FME65B000404 www.brph.com Copyright@ 2019 <br /> STATION D7 Architects Engineers, Inc. <br /> 0 0 - Z - <br /> 0 \ F 1_ \ - D AC A V 19020 33rd Ave W,Suite 530 State of Washington <br /> Lynnwood,Washington,98036 Certificate of Authorization <br /> LE: NONE <br /> Engineering Architecture No.33235512 <br /> SCA No.3137 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE Sc ACCEPTABILITY VTB 09/17/19 400HZ ONE LINE DIAGRAM A 09/17/19 <br /> A Issue For Permit - 767 Rate Increase FA VTB SMS 09/17/190 wasg �'r�p THIS DESIGN AND/OR CHECKED <br /> w° Ii'G 7 SPECIFICATION IS APPROVED BEB 09/17/19 <br /> _ SHEET <br /> S`� ' �n ENGINEER TITLE 767 RATE INCREASE - FA 4T <br /> �; ® , , V 'p�� APPROVED BY DEPT. DATE SMS 09/17/19 <br /> 1. CHECKED <br /> c,,, <br /> — ' ` BUILDING <br /> %.5:9c,— <br /> �4074 APPROVED0-0 3 JOB NO. COMP N0.' 4'GISTAR-' ti��oN�L ��� APPROVED DwcNo.VE-18-30055-602- ION ELECTRICAL MASTER EVERETT, WA 40-023-E4T-602 <br />