Page 2 of 5 <br />Task 2: Compliance Groundwater Monitoring, Additional Sampling Event <br />In June 2021, the Washington State Department of Ecology requested one additional compliance groundwater <br />sampling event to be completed during summer 2021. The scope of work related to this task is as follows: <br />1. Update GeoEngineers' health and safety plan for on -site field work. <br />2. Complete one additional quarterly groundwater compliance sampling event of five site monitoring wells <br />using low -flow samplingtechniques. Submit the groundwater samples for chemical analysis of PAHs, diesel <br />and oil -range petroleum hydrocarbons, gasoline -range petroleum hydrocarbons, volatile organic <br />compounds, total and dissolved arsenic, total and dissolved chromium, and total and dissolved lead. Prior <br />to sampling, the wells will be purged until water quality parameters stabilize and/or three well volumes are <br />removed. Chemical testing will be performed on a standard turnaround time by an Ecology -certified <br />environmental laboratory under subcontract to GeoEngineers. Depths to groundwater will be measured <br />prior to sampling. <br />3. Evaluate groundwater chemical analytical results relative to MTCA cleanup levels. <br />4. IDW water from monitoring well installation will be drummed and left on site at a location designated by <br />the City. Costs for IDW disposal are not included in this scope of work; the City has advised IDW disposal <br />will be completed by others during Property redevelopment. <br />5. Incorprorate the results of the 5th compliance groundwater monitoring event into the compliance <br />groundwater monitoring report summarizing the results of the quarterly compliance groundwater <br />monitoring events. The draft report will be submitted to the City for review and comment. Comments will <br />be incorporated into the final prior to submittal to Ecology under the VCP. <br />Task 3: Regulatory Support <br />1. Communicate and meet with Ecology to discuss the additional groundwater monitoring results, VCP <br />submittals and Ecology opinion letter. <br />2. Submit the 5th quarterly event groundwater results into the environmental data into Ecology's <br />Environmental Information Management (EIM) database as required under MTCA. <br />3. Provide supporting environmental consulting or meetings with the City related to the compliance <br />monitoring. <br />4. Perform routine project management, budget tracking, and invoicing. <br />FEE ESTIMATE <br />The total estimated fee for this Scope of Work is $27,960 which consists of GeoEngineers' labor ($13,377) <br />and subcontracted services ($14,583). A breakdown of the fee estimate is summarized in Exhibit B. <br />GeoEngineers, Inc. <br />File No. 0661108-03 <br />